6.3.2 Disconnection
From the panel or from console it’s necessary dial the USER code, to select the menu :
Press the button or
or dial the USER code
During this operation, the ventual flashing of the yellow LED, indicates that is current the delay of entry
after the opening of a delayed zone and that doesn’t disconnect in the maximal programmed time,will be
activated a round of alarm.
The LED “ALARM MEMORY ” flashing if verificate a round of alarm during the time of monitoring of the
central unit.
The disconnection of the central unit it’s possible also from voice menu with access from the panel of the
central or from remote through telephone connection.Inboth cases , after dial user code, dial to
disconnection.
6.3.3 Stop alarm
In the case of alarm it’s possible to stop the acoustic signal and to stop the calls:
from the panel of the central unit or from a console dial the COMMANDS and to select the menu :
Confirm with the button or .
This command doesn’t connect the burglar alarm system.
The command of connection/disconnection from the panel and from external command devices (PX, SK,
KB) stops the round of alarm and disconnect the central unit. (In the case of alarm 24h at central
disconnected,the connection command resets signals, but doesn’t connect the central unit .
D i s a r m e d
0 - D I S C O N N E C T I O N
1 - S t o p R O U N D
T o t A l a r m
I N S D I S A B L E D
S e r v . P r o v . E N
0
0
security
50
6.3.4 Activation exit
When the exit is programmed to operating to “Command ON/OFF” (see the paragraph 3.3.21) it’s
possible to command the exit from the panel and from the console or from the telephone.
Dial on thje panel of the central unit the USER code followed by :
On the display appear:
To modificate the state of exit dial and on the display appear:
Dial now to come back to initial condition.
This operation can be executed also through Voice menu .
Dial to activate the voice menu and after the USER code, , .
Dial to activate the exit ,or to disactivate.
Similar connecting through phone line after inserted the commands code dial on the phone pad
to “activation exit” and to execute the voice indications.
NOTE: if you program “Function OUT + INT" = "ON on connected” the exit + INT indicates the status
conencted/disconnected of the central unit and cannot be commanded independently.
6
7 = O N 9 = O F F
O U T : D i s a b l e d
7
7 = O N 9 = O F F
O U T : D i s a b l e d
9
6
7
9
6
security
Use of the central unit
51
XR400GSM
- XR