24
English
224936
*224936*
▶
Use the tapered adapter to connect both ends of the hose together conveniently for transport.
8.2
Storage
▶
Store the vacuum cleaner in a secure, dry place where it is inaccessible to unauthorized users.
9
Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact
Hilti
Service.
9.1
Troubleshooting
Trouble or fault
Possible cause
Action to be taken
The warning tone is acti-
vated (reduced suction per-
formance).
The dust bag is full.
▶
Change the dust bag.
The filter element is clogged with
dirt or dust.
▶
Change the filter element.
The hose, vacuum cleaner or dust
hood is clogged with dust.
▶
Clean the hose and dust hood.
The hose diameter setting is incor-
rect.
▶
Set the correct hose diameter.
Dust is blown out of the appli-
ance.
The filter element is not fitted cor-
rectly.
▶
Remove the filter element and
refit it correctly.
The filter element is damaged.
▶
Fit a new filter element.
The filter seal is damaged.
▶
Fit a new filter element.
The appliance switches itself
off or on inadvertently or the
user receives electric shocks
(static discharge).
Electrostatic charge is not
dissipated correctly; The
appliance is connected to an
unearthed/ungrounded power
outlet.
▶
Connect the appliance to an
earthed/grounded power outlet
and use an antistatic hose.
The appliance doesn’t start or
switches itself off after a short
time.
The water level cut-out is acti-
vated.
▶
Clean the probe and the area
around the probe with a brush.
The motor doesn’t restart.
The mains circuit breaker has been
tripped.
▶
Reset the circuit breaker. Find
the reason for the overload
current if it trips again.
The container is full.
▶
Switch the appliance off and
empty the waste material
container.
The motor overheating protection
cut-out has been activated.
▶
Switch off the appliance and
allow it to cool for 5 minutes.
▶
Contact Hilti Service if the motor
cannot be restarted.
The motor overheating protection
cut-out switches the motor off re-
peatedly because the air vents are
clogged.
▶
Clean the ventilation slots
carefully with a dry brush.
The motor doesn’t run when
set to “AUTO”.
The electric tool is faulty or is not
plugged in fully.
▶
Check the electric tool for
correct operation and plug it in
fully.
The automatic filter element
cleaning system doesn’t
work.
No suction hose is connected.
▶
Connect the suction hose.