16
en
Ensure that the tool is disconnected from the mains
supply.
6.1 Fitting the side handle
1. Release the side handle clamping band by turning the
handle in a counter-clockwise direction.
2. Fit the side handle clamping band over the chuck and
onto the cylindrical section of the gear housing.
3. Pivot the side handle into the desired position.
4. Secure the side handle by turning the handle in a clock-
wise direction.
6.2 Fitting the depth gauge
1. Release the side handle clamping band by turning the
handle in a counter-clockwise direction.
2. Slide the depth gauge through the two guide holes in
the depth gauge holder on the side handle clamping
band. (The depth gauge can be clamped in position
above the tool or pivoted through 90° to the side of
the tool opposite the function selection switch.)
3. Secure the side handle by turning the handle in a clock-
wise direction.
6.3 Use of extension cords
Use only extension cords of a type approved for the appli-
cation and with conductors of adequate cross section.
Recommended minimum conductor cross section and
max. cable lengths:
Mains voltage
Conductor cross section
AWG
1,5 mm
2
2,0 mm
2
2,5 mm
2
3,3 mm
2
14 12
100 V
–
30 m
–
50 m
–
–
110–120 V
20 m
30 m
40 m
50 m
75 ft
125 ft
220–240 V
50 m
–
100 m
–
–
–
Do not use extension cords with 1.25 mm
2
or 16 AWG
conductor cross sections.
6.4 Use of a generator or transformer
This tool may be powered by a generator or transformer
which fulfils the following conditions:
– AC voltage output, power output at least 2600 W
– The operating voltage must be 5% and –15%
of the rated voltage at all times.
– Frequency range 50–60 Hz, never above 65 Hz
– Automatic voltage regulation with starting boost
Never operate other tools or appliances from the generator
or transformer at the same time. Switching other tools
or appliances on and off may cause undervoltage and /
or overvoltage peaks, resulting in damage to the tool.
6.5 Activating the tool
See operating instructions TPS theft protection systems.
6. Before use
-CAUTION-
●
The insert tool may become hot during
use.
●
There is a risk of burning the hands.
●
Wear protective gloves when changing
insert tools.
7. Operation
Never use the tool without the side handle.
Use a vice or clamp to secure loose workpieces.
7.1 Fitting the insert tool
1. Unplug the supply cord from the mains socket.
2. Check that the connection end of the insert tool is clean
and lightly greased. Clean it and grease it if necessary.
3. Check that the sealing lip of the dust shield is clean
and in good condition. Clean the dust shield if neces-
sary or replace it if the sealing lip is damaged (see sec-
tion 8).
4. Insert the insert tool in the chuck and rotate it while
applying slight pressure until it engages in the guide
grooves.
5. Push the insert tool further into the chuck until it is
heard to engage.
6. Check that the insert tool has engaged correctly by
pulling on it.
7.2 Removing the insert tool
1. Unplug the supply cord from the mains socket.
2. Open the chuck by pulling back the locking sleeve.
3. Pull the insert tool out of the chuck.
7.3 Adjusting the depth gauge
1. Release the depth gauge clamping screw.
2. Slide the depth gauge into the desired position.
3. Tighten the depth gauge clamping screw.
Содержание TE46
Страница 1: ...TE46 TE56 TE56 ATC 369438 369438 Operating instructions en...
Страница 2: ...11 10 9 8 7 6 4 5 1 2 3 1...
Страница 3: ...3 2 5 8 6 4 2 7 1 2 3 1 1 3 2 4 2 3 1 6 4 5 4 1 3 2 6 3 7 2 4 2 5 6 1 8 5 3 2 2 1 8 6 4 9 5 1 3 2 7...
Страница 4: ...203086 TE Y 18 SDS max TE 46 TE 56 TE 56 ATC 10...