background image

16

en

Ensure that the tool is disconnected from the mains
supply.

6.1 Fitting the side handle 

1. Release the side handle clamping band by turning the

handle in a counter-clockwise direction.

2. Fit the side handle clamping band over the chuck and

onto the cylindrical section of the gear housing.

3. Pivot the side handle into the desired position.
4. Secure the side handle by turning the handle in a clock-

wise direction.

6.2 Fitting the depth gauge 

1. Release the side handle clamping band by turning the

handle in a counter-clockwise direction.

2. Slide the depth gauge through the two guide holes in

the depth gauge holder on the side handle clamping
band. (The depth gauge can be clamped in position
above the tool or pivoted through 90° to the side of
the tool opposite the function selection switch.)

3. Secure the side handle by turning the handle in a clock-

wise direction.

6.3 Use of extension cords

Use only extension cords of a type approved for the appli-
cation and with conductors of adequate cross section.

Recommended minimum conductor cross section and
max. cable lengths:

Mains voltage

Conductor cross section

AWG

1,5 mm

2

2,0 mm

2

2,5 mm

2

3,3 mm

2

14 12 

100 V

30 m

50 m

110–120 V

20 m

30 m

40 m

50 m

75 ft

125 ft

220–240 V

50 m

100 m

Do not use extension cords with 1.25 mm

2

or 16 AWG

conductor cross sections.

6.4 Use of a generator or transformer

This tool may be powered by a generator or transformer
which fulfils the following conditions:
– AC voltage output, power output at least 2600 W
– The operating voltage must be 5% and –15%

of the rated voltage at all times.

– Frequency range 50–60 Hz, never above 65 Hz
– Automatic voltage regulation with starting boost
Never operate other tools or appliances from the generator
or transformer at the same time. Switching other tools
or appliances on and off may cause undervoltage and /
or overvoltage peaks, resulting in damage to the tool.

6.5 Activating the tool

See operating instructions TPS theft protection systems.

6. Before use

-CAUTION-

The insert tool may become hot during
use.

There is a risk of burning the hands.

Wear protective gloves when changing
insert tools.

7. Operation

Never use the tool without the side handle.
Use a vice or clamp to secure loose workpieces.

7.1 Fitting the insert tool 

1. Unplug the supply cord from the mains socket.
2. Check that the connection end of the insert tool is clean

and lightly greased. Clean it and grease it if necessary.

3. Check that the sealing lip of the dust shield is clean

and in good condition. Clean the dust shield if neces-
sary or replace it if the sealing lip is damaged (see sec-
tion 8).

4. Insert the insert tool in the chuck and rotate it while

applying slight pressure until it engages in the guide
grooves.

5. Push the insert tool further into the chuck until it is

heard to engage.

6. Check that the insert tool has engaged correctly by

pulling on it.

7.2 Removing the insert tool 

1. Unplug the supply cord from the mains socket.
2. Open the chuck by pulling back the locking sleeve.
3. Pull the insert tool out of the chuck.

7.3 Adjusting the depth gauge 

1. Release the depth gauge clamping screw.
2. Slide the depth gauge into the desired position.
3. Tighten the depth gauge clamping screw.

Содержание TE46

Страница 1: ...TE46 TE56 TE56 ATC 369438 369438 Operating instructions en...

Страница 2: ...11 10 9 8 7 6 4 5 1 2 3 1...

Страница 3: ...3 2 5 8 6 4 2 7 1 2 3 1 1 3 2 4 2 3 1 6 4 5 4 1 3 2 6 3 7 2 4 2 5 6 1 8 5 3 2 2 1 8 6 4 9 5 1 3 2 7...

Страница 4: ...203086 TE Y 18 SDS max TE 46 TE 56 TE 56 ATC 10...

Страница 5: ...rts of the Tool Removable depth gauge Function selection switch Control switch lockbutton Control switch Supply cord Activation indicator anti theft device Service indicator Indicator for reduced powe...

Страница 6: ...Setting tools with TE Y connection end Quick release chuck Quick release chuck 60208 for wood and metal drill bits with cylindrical or hex shank TE46 Chuck holder 264758 TE56 TE56 ATC Chuck holder 263...

Страница 7: ...dia Diameter range with drill bits for wood 10 32 mm dia Diameter range with drill bits for metal Up to 20 mm dia Drilling performance in medium hard concrete 20 dia 350 mm min Double insulated in acc...

Страница 8: ...afety In addition to the information relevant to safety given in each of the sections of these operating instructions the following points must be strictly observed at all times The tool may be operat...

Страница 9: ...f the tool make it difficult to hold and under unfavorable conditions may lead to electric shocks 5 3 3 Thermal The insert tool may become hot during use You should therefore wear protective gloves wh...

Страница 10: ...W The operating voltage must be within 5 and 15 of the rated voltage at all times Frequency range 50 60 Hz never above 65 Hz Automatic voltage regulation with starting boost Never operate other tools...

Страница 11: ...the mechanical clutch This system offers additional safety while drilling by quickly switching off the tool for example when the drill bit sticks on contacting a reinforcing bar or when the insert too...

Страница 12: ...h Do not permit foreign objects to enter the interior of the tool Clean the outside of the tool at regular intervals using a slightly damp cloth Do not use a spray steam pressurecleaningequipmentorrun...

Страница 13: ...so that the clamping band and side handle are engaged in the groove See 6 3 10 Disposal Most of the materials from which Hilti electric tools are manufactured can be recycled The materials must be cor...

Страница 14: ...n particular Hilti is not obligated for direct indirect incidental or consequential damages losses or expenses in con nection with or by reason of the use of or inability to use the tool for any purpo...

Страница 15: ...FL 9494 Schaan Tel 423 2342111 Fax 423 2342965 www hilti com Hilti registered trademark of Hilti Corp Schaan W 2735 0203 10 Pos 1 1 Printed in Liechtenstein 2003 Right of technical and programme chang...

Отзывы: