Storage
CAUTION
Accidental damage caused by defective or leaking batteries
!
▶
Always store your products with the batteries removed!
▶
Store the tool and batteries in a place that is as cool and dry as possible.
▶
Never store batteries in direct sunlight, on heating units or behind a window pane.
▶
Store the tool and batteries in a place where they cannot be accessed by children or unauthorized
persons.
▶
Check the tool and batteries for damage before use after long periods of storage.
9
Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact
Hilti
Service.
9.1
Blind-rivet setting tool is not in working order
Malfunction
Possible cause
Action to be taken
The LEDs do not light up.
The battery is not fully inserted.
▶
Push the battery in until it
engages with a click.
The battery is discharged.
▶
Change the battery and charge
the empty battery.
The battery is too hot or too cold.
▶
Bring the battery to the recom-
mended working temperature.
1 LED flashes.
The battery is discharged.
▶
Change the battery and charge
the empty battery.
The battery is too hot or too cold.
▶
Bring the battery to the recom-
mended working temperature.
4 LEDs flash.
Product momentarily overloaded.
▶
Release the control switch and
then press it again.
Protection against overheating.
▶
Allow the product to cool down
and clean the air vents.
Overload LED flashes for 10
seconds.
Overload protection.
▶
Remove metallic residues .
Blind rivet is not set.
The battery is discharged.
▶
Change the battery and charge
the empty battery.
Jaws are dirty or worn.
▶
Clean the jaws or, if applicable,
→ page 19 replace them.
Jaw housing not correctly screwed
on.
▶
Screw the jaw housing on
correctly . → page 20
Spring weak or defective.
▶
Replace the spring . → page 19
No rivet mandrel disposal.
Use of the wrong nosepiece.
▶
Change the nosepiece .
Nosepiece is worn.
▶
Change the nosepiece .
Rivet mandrel wedged in jaws.
▶
Remove the rivet-mandrel
residues from the jaw housing .
Steel sleeve is dirty.
▶
Clean the steel sleeve .
Mandrel container is full.
▶
Empty the mandrel container .
Printed: 30.07.2019 | Doc-Nr: PUB / 5466619 / 000 / 02
Содержание RT 6-A22
Страница 2: ...1 Printed 30 07 2019 Doc Nr PUB 5466619 000 02...
Страница 4: ...Printed 30 07 2019 Doc Nr PUB 5466619 000 02...
Страница 162: ...158 Magyar 2225140 2225140 Printed 30 07 2019 Doc Nr PUB 5466619 000 02...
Страница 163: ...Printed 30 07 2019 Doc Nr PUB 5466619 000 02...
Страница 164: ...Printed 30 07 2019 Doc Nr PUB 5466619 000 02...
Страница 165: ...Printed 30 07 2019 Doc Nr PUB 5466619 000 02...
Страница 166: ...Printed 30 07 2019 Doc Nr PUB 5466619 000 02...
Страница 167: ...Printed 30 07 2019 Doc Nr PUB 5466619 000 02...