![Hilti PS 38 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/hilti/ps-38/ps-38_operating-instructions-manual_2136442016.webp)
2. The scan has been made longitudinally, i.e. along
the length of an object. In this case, move the tool up
or down and repeat the scan (see fig. 6 on the cover
pages).
7. Care and maintenance
7.1 Cleaning and drying
1.
Use only a clean, soft cloth for cleaning. If
necessary, moisten the cloth slightly with pure
alcohol or a little water.
NOTE
Do not use any other liquids as these may
damage the plastic components.
2.
The temperature limits for storage of your equip-
ment must be observed, especially in winter /
summer.
7.2 Storage
Put the tool into storage only when dry. Please ob-
serve the applicable temperature limits when storing
the tool.
Check the accuracy of the equipment before it is used
after a long period of storage.
Remove the batteries from the tool before storing it
for a long period. Leaking batteries may damage the
tool.
7.3 Transport
Use the Hilti toolbox or equivalent packaging when
transporting the tool.
CAUTION
Always remove the batteries before shipping the
tool.
7.4 Hilti Calibration Service
We recommend that the tool is checked by the Hilti
Calibration Service at regular intervals in order to
verify its reliability in accordance with standards and
legal requirements.
Use can be made of the Hilti Calibration Service
at any time, but checking at least once a year is
recommended.
The Calibration Service provides confirmation that the
tool is in conformance, on the day it is tested, with
the specifications given in the operating instructions.
After checking, a calibration sticker applied to the tool
and a calibration certificate provide written verification
that the tool is operating in accordance with the
manufacturer’s specification.
Calibration certificates are always required by com-
panies certified according to ISO 900x.
Your local Hilti Center or representative will be pleased
to provide further information.
8. Troubleshooting
Fault
Possible cause
Remedy
The tool can’t be switched on.
The batteries are exhausted.
Replace the batteries.
Incorrect battery polarity.
Insert the batteries correctly and
close the battery compartment
cover.
The tool is switched on but
doesn’t react.
System error.
Remove and reinsert the batteries.
The tool is too cold or too
hot.
The tool is too cold or too hot.
Wait until it is within the permiss-
ible temperature range.
“Slipping wheel” is shown in
the display.
A wheel lost contact with the wall.
Press the “Measure” button. Take
care to ensure that the wheels re-
main in contact with the surface
when moving the tool. On uneven
surfaces, place a sheet of thin card-
board between the wheels and the
wall.