4 Technical data
4.1 Direct fastening tool
Weight
DX 5 GR
3.43 kg
Tool length
DX 5 GR
495 mm
Nail length
DX 5 GR
≤ 22 mm
Recommended maximum fas-
tening rate
DX 5 GR
700 rev/h
Application temperature (ambi-
ent temperature)
DX 5 GR
−20 ℃ … 50 ℃
Compression stroke
DX 5 GR
32 mm
Pressure required
DX 5 GR
≥ 50 N
4.2 Noise information determined in accordance with EN 15895
The sound pressure and vibration values given in these instructions have been measured in accordance
with a standardized test and may be used to compare one fastening tool with another. They may be used
for a preliminary assessment of exposure. The data given represents the main applications of the fastening
tool. However, if the fastening tool is used for different applications, with different accessories or is poorly
maintained, the data may vary. This may significantly increase exposure over the total working period. An
estimation of the level of exposure should also take into account the periods of time when the tool is not
actually in use. This may significantly reduce exposure over the total working period. Prescribe additional
safety measures to protect the operator from the effects of noise and/or vibration, such as: Maintenance of
the direct fastening tool and its additional equipment or accessories, keeping the operator's hands warm,
organization of work procedures.
The noise values listed were determined under the following conditions:
Noise information conditions
Cartridge
6.8/11 caliber, black
Power setting
2
Application
Fastening 24 mm wood to concrete (C40) with XU47 P8
Noise information in accordance with EN 15895
Sound (power) level (L
WA
)
105 ±2 dB
Emission sound pressure level (L
pA
)
101 ±2 dB
Peak sound pressure emission level (L
pCpeak
)
133 ±2 dB
4.3 Vibration
The vibration value that must be specified in accordance with 2006/42/EC does not exceed 2,5 m/s².
Further information about user health and safety can be found on the Hilti website at: www.hilti.com/hse
5 Operation
5.1 Safety devices
Note
Before commencing work, check that all safety devices are fitted and that they are functioning correctly.
All parts must be fitted correctly and fulfill all conditions necessary for the correct operation of the tool.
Printed: 20.03.2017 | Doc-Nr: PUB / 5292603 / 000 / 01
Содержание DX 5 GR
Страница 2: ...1 Printed 20 03 2017 Doc Nr PUB 5292603 000 01 ...
Страница 3: ...2 3 4 5 Printed 20 03 2017 Doc Nr PUB 5292603 000 01 ...
Страница 4: ...6 7 8 Printed 20 03 2017 Doc Nr PUB 5292603 000 01 ...
Страница 5: ...9 10 11 12 Printed 20 03 2017 Doc Nr PUB 5292603 000 01 ...
Страница 312: ...306 ע ב ר י ת Printed 20 03 2017 Doc Nr PUB 5292603 000 01 ...
Страница 313: ...Printed 20 03 2017 Doc Nr PUB 5292603 000 01 ...