Typical use cases of the netRAPIDs
84/145
netRAPID Chip Carrier | Getting Started
DOC131104GS04EN | Revision 4 | English | 2017-09 | Released | Public
© Hilscher 2014 - 2017
3. Add netRAPID as PROFIBUS DP slave.
In the
Fieldbus
tab of the
Device Catalog
(right window), open the
PROFIBUS DPV1
>
Gateway / Stand-Alone
Slave
folder. Then select
the
NRP 10-DPS/DPS
item and drag & drop it onto the PROFIBUS
network line next to the PC Card cifX.
Figure 59: Add netRAPID as PROFIBUS Slave in SYCON.net
You have added the netRAPID as PROFIBUS Slave in the PROFIBUS
network.
4. Assign driver to PC Card cifX (PROFIBUS DP master).
Double-click the
CIFX_DP_DPM
symbol in the bus configuration line or
select the symbol and choose
Configuration…
entry from the context
menu.
The
Configuration
dialog window opens.
In the
Navigation Area
, select
Settings
>
Driver
.