Technical Data
67/78
COMX Communication Modules | Design Guide
DOC100901DG18EN | Revision 18 | English | 2013-12 | Released | Public
© Hilscher, 2002-2013
4 Technical
Data
Operating Condition
Minimum
Maximum
Operating temperature [° C]
COMX
Standard
-20°
C
COMX 100CA-RE and
COMX 50-CA-CCS:
0° C
+65° C
COMX 100CA-RE up
to Rev:7 and
COMX 100CN-RE:
+60° C
Storage temperature [° C]
Standard
Extended
-25° C
-40° C
+70° C
+85° C
Operating voltage [V]
U1
+3.1 V
+3.5 V
Typical Maximum
Operating current [mA]
COMX 10XX-CCS
U1
225 mA
260 mA
COMX 10XX-COS
U1
250 mA
290 mA
COMX 10XX-DPS
U1
200 mA
230 mA *
1005 mA **
COMX 10XX-DNS
U1
250 mA
290 mA
COMX 50XX-CCS
U1
270 mA
350 mA
COMX 50XX-REFO
U1
950 mA
1100 mA
COMX 51XX-RE
U1
700 mA
COMX 100XX-CO
U1
450 mA
480 mA
COMX 100XX-DN
U1
440 mA
470 mA
COMX 100XX-DP
U1
430 mA
460 mA *
COMX 100XX-RE
U1
700 mA
700 mA
Table 42: Technical Data – Operating Conditions
* Maximum current for normal operation
** Maximum current in case of bus short circuit (Pin 6 (+5 V) against pin 5 (ISOGND))
EMC
Generic Standard
Basic Standard
Immunity EN
61000-6-2
(1999)
Industrial Environment
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
Details are listed in
chapter 4.1
Emission EN
61000-6-4
EN55011
Table 43: Technical Data - EMC
Mechanical Dimensions
Minimum
Maximum
Dimensions
COMX
30 x 70 x 21.5 mm
40 x 70 x 21.5 mm
for further extension
Weight
35 gr.
40 gr.
Table 44: Technical Data – Mechanical Dimensions