Water Pump Sets
Parameter
Default
Min
÷
Max
Description
Water Flow Sets:
Flow1 sets: [%]
33
10
÷
100
First level water flow setting.
If HDC or Spray is activated the default is 25.
Water Flow Sets:
Flow2 sets: [%]
66
10
÷
100
Second level water flow setting.
If HDC or Spray is activated the default is 50.
Water Flow Sets:
Flow3 sets: [%]
100
10
÷
100
Third level water flow setting.
If HDC or Spray is activated the default is 90.
Chemical Sets
Parameter
Default
Min
÷
Max
Description
Chemical Pump Sets:
PulseDuration: [%]
75
1
÷
100
Setting the detergent pump single pulse duration.
Chemical Pump Sets:
ChemPercSets: [%]
2,0
0,5
÷
3,0
Position 1 of the detergent percentage selector.
Vacuum Sets
Parameter
Default
Min
÷
Max
Description
Vacuum Sets:
Max Mot current: [A]
40
10
÷
40
Maximum current from the main board to the vacuum motor.
Vacuum Sets:
Nom. Mot current: [A]
27
5
÷
30
Rated current; with T Nom manages the amperometric protection
(alarm + stop vacuum motor).
Vacuum Sets:
Nom. Motor time: [s]
10
1
÷
10
Rated timer; with I Nom manage the amperometric protection (alarm
+ stop vacuum motor).
Vacuum Sets:
Switch off delay: [s]
5
0
÷
30
Delay of switching on of the vacuum motor when the switch is
pressed.
Vacuum Sets:
Reset delay: [s]
15
0
÷
100
Delay of switching off of the vacuum motor when the safety lever is
released
Vacuum Sets:
Ecomode voltage: [V]
17
15
÷
20
Value of Voltage reduction of vacuum motor, during ECO mode
45