3.2.6
The suction Motor doesn’t work
All the other devices of the machine are functioning properly
1.
Check the voltage on
the connectors (with
running machine)
V
≥
23
YES
⇒
Replace the
motor
NO
⇒
Point 2
2.
Check the voltage on
the connector
J1 Pink & Red
(with
running machine)
V
≥
23
YES
⇒
Replace the
cables
NO
⇒
Replace the
control card
3.2.7
The Pump doesn’t work
All the other devices of the machine are functioning properly
1.
Check the voltage in
AC
on the Pump’s
connectors, Don’t
disconnect the
connectors from the
pump (with running
machine)
V
≥
13
YES
⇒
Replace the
pump
NO
⇒
Point 2
2.
Check the voltage in
AC
on the connector
J1 Green & Yellow
(with running
machine)
V
≥
13
YES
⇒
Replace the
cables
NO
⇒
Replace the
control card