Hill-Rom The Progressa Скачать руководство пользователя страница 22

©2013 Hill-Rom Services, Inc. ALL RIGHTS RESERVED – INTL. Version
For detailed Warning and Caution statements, and operating instructions,  refer to the Progressa™ Bed User Manual

Bed Flat Control

Return the patient deck to the level position 
from any articulated position.

To activate:

Press and 

hold

the ‘

Bed Flat

’ control

Tip:

The individual sections move into the flat 
position.  If the bed is starting in the chair 
position, then it will move through the reclining 
position on the way to level.

When all sections are flat, the bed stops and one 
beep sounds.

21

Содержание The Progressa

Страница 1: ...2013 Hill Rom Services Inc ALL RIGHTS RESERVED INTL Version The Progressa Bed System Bed Controls Quick Reference Guide...

Страница 2: ...tructions refer to the Progressa Bed User Manual The Progressa Bed System Foot Controls Night Light Removable Headboard Removable Footboard Intellidrive Transport System Controls Graphic Caregiver Int...

Страница 3: ...trol FlexAFoot Controls Boost Control Chair Control Bed Flat Service Indicator Battery Life Indicator Side Exit Assist Head Up Down Controls Knee Up Down Controls Bed Up Down Controls Lock Out Control...

Страница 4: ...me Screen Screen Lock Lowest Bed Position Indicator Green indicates the bed is in the lowest position Yellow indicates the bed is not in the lowest position Alarms Scale Surface Controls Pulmonary The...

Страница 5: ...tay on for 60 seconds To activate Press and hold the Enable control until the indicator light comes on During the 60 second period you may activate the bed controls on the pendant without pressing the...

Страница 6: ...ons refer to the Progressa Bed User Manual Unlocking and Locking the Screen To activate Unlocking Screen Slide your finger across screen left to right toward the unlock symbol The 5 lights will turn g...

Страница 7: ...Progressa Bed User Manual Zero New Patient To activate Make sure the patient is not in bed Put bed in required position Press the Scale control on the GCI Press Zero Press New Patient 1 Erases Scale H...

Страница 8: ...b 3 Press Zero the Bed and follow on screen instructions To weigh the patient 1 Make sure the patient is in the center of the bed 2 Press the Scale tab 3 Press Weigh Patient and follow on screen instr...

Страница 9: ...ctions To weigh the patient Make sure the patient is in the center of the bed Press the Scale tab Press Weigh Patient and follow on screen instructions You will be prompted to put the bed into the rec...

Страница 10: ...tatements and operating instructions refer to the Progressa Bed User Manual BMI Calculator To activate Press the Scale tab on home screen Press the Scale option Press the BMI button Slide finger on He...

Страница 11: ...ate On the Siderails Press and hold the Bed Up or Bed Down button to desired position On the Caregiver Pendant First press and hold the Enable button to activate controls Press and hold the Bed Up or...

Страница 12: ...Progressa Bed User Manual FlexAfoot Mechanism Allows the caregiver to customize the overall length of the bed and sleep surface to the patient The bed and surface can be retracted up to 10 25 cm To a...

Страница 13: ...by using the Head Up Down controls Use the Line of Site Angle Indicators or GCI home screen to see the specific angle To activate On the Siderails Press and hold the Head Up or Head Down button to de...

Страница 14: ...erating instructions refer to the Progressa Bed User Manual Knee Up Down Raise and lower the knee section by using the Knee Up Down controls To activate Press and hold the Knee Up Down controls to rea...

Страница 15: ...etailed Warning and Caution statements and operating instructions refer to the Progressa Bed User Manual Foot Up Down Raise and lower the foot section by using the Foot Up Down controls To activate Pr...

Страница 16: ...es side to side Continuous Lateral Rotation Therapy CLRT to aid in the prevention and treatment of pulmonary complications related to immobility To activate Select Pulmonary Therapy control on the GCI...

Страница 17: ...al Percussion Vibration Percussion Vibration helps loosen secretions in the lungs and helps move lung secretions for easier removal To activate Select the Pulmonary Therapy control on the GCI Select P...

Страница 18: ...the Progressa Bed User Manual Deactivate Therapies To deactivate Select the Pulmonary Therapy control on GCI Press the Stop Therapies button and follow the instructions on the GCI screen NOTE If P V a...

Страница 19: ...rogressa Bed User Manual Reverse Trendelenburg Tilt Table To activate Prior to activation of the Tilt Table position always use Flexafoot to adapt to the individual patient Press and hold the Reverse...

Страница 20: ...hold the Chair button on the siderail or caregiver pendant to go into the FullChair position The patient deck will slightly recline backwards as the seat and lumbar sections on the mattress slightly...

Страница 21: ...he bed has reached the FullChair position when the articulation stops and a tone sounds NOTE If the footboard is not installed the bed will proceed into the chair egress position Required removal of f...

Страница 22: ...d Flat Control Return the patient deck to the level position from any articulated position To activate Press and hold the Bed Flat control Tip The individual sections move into the flat position If th...

Страница 23: ...tivate Raise or lower the bed so the patient s feet will be flat on the floor Press the Side Exit Assist button located on head end siderail until the indicator light turns green The surface will begi...

Страница 24: ...ntly off the frame of the bed Exiting patient moves away from the center of the bed towards an egress point Position patient moves toward either siderail or moves away from the head section such as si...

Страница 25: ...User Manual Alarm Silence Suspend and Deactivation To deactivate Select the Alarms tab Select Bed Exit Select Off The home screen will no longer display the Bed Exit Active icon on left side of scree...

Страница 26: ...sections Raise the foot section Activate the integrated surface Max Inflate feature To activate Step down on CPR pedal until head section reaches the flat position The foot and knee sections will aut...

Страница 27: ...functions preventing bed movement The CPR Control CANNOT be locked out To activate At the same time press the Lockout control and the preferred function control Both the patient and caregiver control...

Страница 28: ...to the head end of the bed To activate Press and hold the Boost control on the siderail The bed will transition to the Trendelenburg position If the bed has an air system the mattress will go into Ma...

Страница 29: ...ry section of the patient surface The bed will stay in max inflate for 30 minutes before returning to normal standard state To activate On the home screen select the Surface tab Select Max Inflate Con...

Страница 30: ...and other nursing procedures Siderails must be in the up position to activate turn assist Once turn assist is initiated you may lower a siderail to facilitate patient care The bed will alarm as a saf...

Страница 31: ...Confirmation On the home screen the Left Turn Assist icon will be highlighted when active To deactivate Select the Surface tab on home screen Select the Normal control Assists caregiver in turning th...

Страница 32: ...erating instructions refer to the Progressa Bed User Manual Seat Deflate This feature allows for easier bedpan placement To activate On the GCI press the Surface tab Press the Seat Deflate control Not...

Страница 33: ...ressa Bed User Manual Opti Rest Opti Rest mode offers increased comfort for the patient while maintaining pressure relief It vents the chest seat and thigh zones producing a massaging wave like action...

Страница 34: ...ogressa Bed User Manual Sleep Mode is used to reduce frequency of air system adjustments for patients who are sensitive to air surface movements After 8 hours the Normal mode reactivates To activate P...

Страница 35: ...comfort levels of the patient To activate Press the Surface tab Press the Patient Comfort tab Use the Comfort Adjustment controls to change the pressure in the head seat and heal section of the mattre...

Страница 36: ...ct the desired history to display Head Angle Time spent with the head of bed more than 30 or 45 since 12am Bed Exit Time spent with the Bed Exit alarm ON Scale Weight increase or decrease in 24 hour p...

Страница 37: ...on statements and operating instructions refer to the Progressa Bed User Manual Weight History To view the weight history Press Scale tab Press History tab Icons will provide information based on Init...

Страница 38: ...cords and communication cords on the hook at the bottom of the transport handle Set the steer pedal to Steer Grip one or both of the transport handles Press at least one of the enable switches on the...

Страница 39: ...tion statements and operating instructions refer to the Progressa Bed User Manual Patient Restraints Hill Rom makes no recommendation regarding the use of physical restraints Users should refer to leg...

Отзывы: