background image

35

Model ORB, ORBH, ONRB & ONRBH

Location Part 

Descriptions

Number     

1

Kickplate

, Storm Grey

2

Master Bumper

, 3/4, 1/2, Featherstone, Smoke, White, French Vanilla, Black

3

Lower Front Panel

, Painted Custom Color (Not Shown)

4

Color Band

, Painted Custom Color or Stainless

9

Deck Pan

, Painted, Unpainted

10

Wire Shelving

, White, With or Without Covers

11

Front Baffle

,  Aluminum

12

Honeycomb

, 1”x 4”x 48”

13

Honeycomb Retainer

, Painted 

15

Upper Rear Baffle

, Center or End

17 

Nose Bumper,

Polymer Custom Color

20

Lower Rear Baffle

, Painted 

23

Electrical Junction Box

, (mounted on bottom left front or on top left rear)

24

“J” Rail

, for Kickplate

25

Top Flue Panel

, Painted

36

Plug Button

, (Not Shown)

55

Door, 

Specify Mask Color, Ardco or Anthony, Door Handle Type, Low or

Medium Temperature Application, Left or Right Hand Swing

56

Door Frame

, Ardco or Anthony, Low or Medium Temperature Application

69

Coil

78

Bumper Retainer

81

Bottom Wire Racks

82

Tag Moulding

, PVC or Aluminum

83

Thermometer

, Includes Bracket

87

End Assembly

, Solid, Custom Color, Identify Left or Right hand, Color of

Panel, and Color of End Trim Color

88

End Kickplate

, Painted, Stainless Steel

E01

Defrost Heaters

E02

Anti-Condensate Heaters

, Discharge

E08

Ballast

, Electronic, (Identify by brand name and model number)

E09

Fan Motor - STATE HIGH EFFICIENCY OR STANDARD

E10

Fan Blade 

E11

Fan Basket

, 8”

E20

Fan Cord-Set

, High Efficiency or Standard

Содержание ONRB

Страница 1: ...HANDBOOK INSTALLATION OPERATION REACH IN BEVERAGE C A S E S P057333G Rev 12 6 06 MODEL ORB ORBH ONRB ONRBH COMPONENT...

Страница 2: ......

Страница 3: ...o make it easier to read and to help you get the most from this innovative new design When you follow the instructions you should expect remarkable performance attractive fits and finish and long case...

Страница 4: ......

Страница 5: ...oil outlet case controls location and other piping tips PLUMBING PAGE 15 Information on drain connections ELECTRICAL HOOKUP AND WIRING DIAGRAMS PAGES 16 25 Complete information on electrical connectio...

Страница 6: ...2...

Страница 7: ...ice Parts Department at 1 800 283 1109 APPARENT DAMAGE A claim for obvious damage must be noted on the freight bill or express receipt and signed by the carriers agent otherwise the carrier may refuse...

Страница 8: ...MATELY 1 INCH TO CASE HEIGHT z WIRING TO THE TOP ADDS APPROXIMATELY 1 INCH TO CASE HEIGHT z A 2 MINIMUM AIR GAP IS REQUIRED BETWEEN THE REAR OF THE CASE AND A WALL z SUCTION LINE ALL LENGTHS 1 2 z LIQ...

Страница 9: ...M 30 7 8 in 78 4 cm 5 1 8 in 13 1 cm 16 1 16 in 40 9 cm 8 1 2 in 21 6 cm 31 9 16 in 80 2 cm 39 1 4 in 99 7 cm 85 1 16 in 216 0 cm 87 1 16 in 221 1 cm 63 in 160 1 cm 66 3 8 in 168 6 cm Door Height 68 i...

Страница 10: ...RIGERATION FRONT OF CASE 10 in 25 4 cm 8 in 20 3 cm 16 1 16 in 40 8 cm 18 9 16 in 47 1 cm 27 9 16 in 70 0 cm 23 1 4 in 59 1 cm 26 7 8 in 68 3 cm 1 1 2 in 3 8 cm END 8 11 16 in 22 1 cm COIL PLENUM 23 1...

Страница 11: ...89 8 cm 5 1 8 in 13 1 cm 16 1 4 in 41 3 cm 8 in 20 3 cm 24 3 16 in 61 4 cm 31 7 8 in 81 0 cm 34 5 8 in 88 0 cm 7 1 2 in 19 1 cm 1 2 BUMPER OPTION 87 1 16 in 221 1 cm 85 1 16 in 216 0 cm 63 in 160 0 cm...

Страница 12: ...9 1 4 3dr CASE 95 1 4 8 CASE 3 DOOR CASE 8 CASE FRONT OF CASE 47 1 2 3dr CASE 49 1 8 8 CASE 6 4 4 4 4 4 4 4 6 23 3 16 NARROW 31 11 16 STANDARD 23 3 16 NARROW 23 3 16 NARROW 23 3 16 NARROW 31 11 16 STA...

Страница 13: ...ERS MAY BE DISCARDED ROLL OUT OF TRUCK When there is a truck level delivery dock cases may be rolled directly from the truck to the store floor CAUTION If skid boards are required to unload cases cast...

Страница 14: ...aser Transit Leveling is necessary to assure prop er case alignment Locate highest point on chalk line as reference for determining height of shim pack levelers A laser transit is recom mended for pre...

Страница 15: ...oining case bumper BUMPER SCREW BUMPER JOINT 1 2 3 5 7 6 4 7 Remove Outriggers Remove cotter pin from outrigger by cutting tie strap Either pull the out rigger out from the front or insert a crowbar i...

Страница 16: ...re adjustable to achieve almost invisible snug fit ting joints and a high level of excellence in fit and finish TRIM OUT BUMPER SCREW BUMPER JOINT 1 Adjust polymer master bumper joints if required Fir...

Страница 17: ...into retainer then down on the J rail Attach the J rail which is shipped loose with the case Line up the rail with the kickplate bracket and secure with the screws provided Once the Streamlyne bumper...

Страница 18: ...stallation and maintenance As the diagrams below indicates the coil outlet hole is positioned forward on the right hand side of the case fully visible in front of the fan plenum An optional piping to...

Страница 19: ...has been installed you will find it very easy to remove See instruc tions below or the trim out section of this manual on page 13 C L 31 9 16 in 80 2 cm STANDARD 1 1 2 PVC DRAIN CONNECTION 33 9 16 in...

Страница 20: ...E ORANGE 23 WIRING NUMBERS AND COLORS EQUIPMENT GROUNDING CONDUCTOR GREEN BLACK WHITE DOOR FRAME ANTI COND HEATERS 120 VOLT 15 16 WIRING TO TOP CONTINUOUS RACEWAY JUNCTION BOX COVER JUNCTION BOX CANOP...

Страница 21: ...prism door lights are located in the door frame for Anthony door frames ANTHONY FRAMES 1 REMOVE CORNER BEADS 2 2 REMOVE ACCESS COVER 3 REPLACE BALLAST ANTHONY FRAMES STEPS TO REPLACE THE BALLAST 1 CO...

Страница 22: ...POWER LEADS LAMP LEADS LAMP 1 LAMP 2 LAMP 3 FILTER BALLAST FOR LAMP 2 BALLAST FOR LAMPS 1 3 POWER LEADS LAMP LEADS LAMP 1 FILTER BALLAST FOR LAMPS 3 4 LAMP 2 LAMP 3 LAMP 4 BALLAST FOR LAMPS 1 2 2 DOOR...

Страница 23: ...FOR LAMPS 4 5 LAMP 2 LAMP 3 LAMP 4 LAMP 5 BALLAST FOR LAMP 3 BALLAST FOR LAMPS 1 2 POWER LEADS LAMP LEADS LAMP 1 BALLAST FOR LAMPS 5 6 FILTER LAMP 2 LAMP 3 LAMP 4 LAMP 5 LAMP 6 BALLAST FOR LAMPS 3 4 B...

Страница 24: ...20 WIRING DIAGRAMS 15 16 ORB ORBH ONRB ONRBH 2 DOOR...

Страница 25: ...21 WIRING DIAGRAMS 15 16 ORB ORBH ONRB ONRBH 3 DOOR 8...

Страница 26: ...22 WIRING DIAGRAMS 15 16 ORB ORBH ONRB ONRBH 4 DOOR 12...

Страница 27: ...IXTURE TYP LAMP 4 LAMP 3 RACEWAY BLUE YELLOW YELLOW BLACK BLUE WHITE BLACK WHT BLK BALLAST WHT BLK BALLAST 15 ANTI 16 COND HEATERS WHITE BLACK BLACK WHITE SCAN X SENSOR BUTTON LOC TOP CASE LIGHT BIMET...

Страница 28: ...LAMP 3 RACEWAY BLUE YELLOW YELLOW BLACK BLUE WHITE BLACK WHT BLK BALLAST WHT BLK BALLAST 15 ANTI 16 COND HEATERS WHITE BLACK BLACK WHITE CASE LIGHT BIMETAL DISC THERMOSTAT BLACK CASE LIGHT SWITCH EVA...

Страница 29: ...25 WIRING DIAGRAMS GFI...

Страница 30: ...04 3 High efficiency fans reduce refrigeration load by 96 BTUHs fan 4 Average discharge air velocity at peak of defrost 8303 8003 BTUH door2 Model 32 34 Evaporator F 36 38 38 40 Return Air F 380 380 D...

Страница 31: ...s 120 Volts Amps 0 31 0 46 0 61 0 77 0 92 0 70 0 93 Watts 18 4 27 6 36 8 46 0 55 2 42 56 Electrical Data ORBH Model 120 Volts 6 If timed off defrost is utilized If electric or hot gas defrost is utili...

Страница 32: ...or 3 door 4 door 5 door Standard Fans Amps 1 00 1 50 2 00 2 50 Watts 60 90 120 150 Defrost Heaters 208 Volts Amps 4 39 4 96 6 51 7 96 Watts 914 1032 1355 1655 240 Volts Amps 5 06 5 71 7 55 9 17 Watts...

Страница 33: ...med off defrost is utilized If electric or hot gas defrost is utilized case only requires 1 defrost per day 7 NOTE not an option on this case model Electric Defrost Defrosts Per Day 46 Model ONRBH Fai...

Страница 34: ...own in diagram 2 below which is in the front left hand side of the case The defrost termination control thermostat and the temperature control thermostat are located inside the junction box on the low...

Страница 35: ...the food product display so that it impinges on the air flow pattern DISCHARGE 1 LOAD LIMIT 2 AIR FLOW 3 RETURN AIR GRILL 4 Overloading will cause malfunction and the loss of proper temperature levels...

Страница 36: ...ning In some installations more than one disconnect switch may have to be turned off to completely de energize the case Check waste outlet to insure it is not clogged before starting the cleaning proc...

Страница 37: ...ed Do not attempt a field modification by altering the blades Fan motors may be changed with an easy two step process without lifting up the plenum thereby avoiding the necessity to unload the entire...

Страница 38: ...34 PARTS ORDERING 23 24 11 9 1 2 17 88 E02 E01 55 4 87 10 15 20 23 E08 E09 E11 E10 E20 12 13 69 81 82 83 25 56 78...

Страница 39: ...rear 24 J Rail for Kickplate 25 Top Flue Panel Painted 36 Plug Button Not Shown 55 Door Specify Mask Color Ardco or Anthony Door Handle Type Low or Medium Temperature Application Left or Right Hand S...

Страница 40: ...ase on which the part is used Length of part if applicable I E 60 90 120 150 or 180 Color of part if painted or color of polymer part Whether part is for left hand or right hand application Whether sh...

Страница 41: ...solution to the coating surface Using gentle pressure wipe glass over the entire surface with soft wipers once in the horizontal direction followed by once in the vertical direction Gently dry the sur...

Страница 42: ...38 NOTES...

Страница 43: ...sales tax or upgrading 5 When the operation is impaired due to improper installation 6 When installation and startup forms are not properly complete or returned within two weeks after startup THIS PLA...

Страница 44: ...cleaning cases the following must be performed PRIOR to cleaning To avoid electrical shock be sure all electric power is turned off before cleaning In some installations more than one switch may have...

Отзывы: