COMPRESSOR INPUT/OUTPUT meter. This 12-digit LED display reads both the level of the 
incoming audio signal and the level at the dynamics processor output. The range is from -30 
to +18 dB.

COMPRESSOR IN/OUT meter switch with LED. This selects whether the gain LEDs read the 
input signal (switch pressed) or the output signal (switch not pressed). Note: This display is 
referenced to the operating level selected with the LEVEL switch on the rear of the unit (-10 
dBV or +4 dBu).

COMPRESSOR ENABLE switch with LED. This activates the corresponding compressor chan-
nel. It provides a so-called “hard bypass”, i.e. if it is OUT or the unit is not connected to the 
mains, the input jack will be linked directly to the output jack. Usually, this switch is used for 
direct A/B comparison between unprocessed and compressed/limited signals.

DYHANCE switch with LED. Activates the dynamic enhancer circuit which allows to dynami-
cally enhance the treble range. Since the bass portions of a music signal often have the high-
est energy yield, they usually are the ones thattrigger the compression process, thus also 
reducing the gain of middle to high frequencies. The enhancer controls the compression 
process and gradually adds more highs, the stronger the treble range is compressed, so as 
to make up for the subjective loss of high-frequency content.

DE-ESSER LEVEL control. The controllable de-esser helps to eliminate hiss noise contained in 
the audio signal. This control determines the amount of frequency suppression.

MALE switch with LED. This switch adapts the de-esser to the male (switch pressed) or female 
registers (not pressed).

DE-ESSER LEVEL DISPLAY. This LED chain shows the attenuation within a range from +3 to 
+12 dB.

DE-ESSER IN/OUT switch with LED. Switches the de-esser on and off. Note: the de-esser is 
placed in the side-chain path of the compressor, so it will operate only if the compressor is 
active.

LIMITER control. If this control is turned fully to the right, the limiter is switched off. Owing to 
its extremely fast “zero” attack, this circuit is capable of limiting signal peaks without any over-
shoot. If the signal is limited for more than 20 ms,the overall gain is reduced for about 1 s to 
avoid strong and thus audible limiter effects.Note: If you wish to use the peak limiter as a 
protecting device, the LIMITER control and the OUTPUT control in the compressor section 
should be set so that the peak limiter responds only rarely or never at all. It should be triggered 
by peak signals only. To achieve creative sound effects, on the other hand, you can also inten-
tionally drive the peak limiter into this peak limiting range.

LIMIT LED. This lights up as soon as the limiter is on.

LINK switch with LED. This switch links the channels. In linked mode, dynamics are controlled 
by using channel 1 switches and controls, whereby the control signal is derived from the 
energy of both side chain channels (true stereo processing). Therefore, all switches and 
controls of channel 2 (except for IN/OUT, SC EXT, SC MON, LoCONT, WARMTH, DE-ESSER, 
MALE, DYHANCE, I/O METER switches and OUTPUT, DE-ESSER LEVEL) will be disabled when 
activating the LINK switch.

POWER switch. Switches the unit on and off. Make sure to switch the unit off when not in use.

26

27

28

29

30

31

32

33

34

35
36

37

Содержание RPD-2200

Страница 1: ...RevA 06 2017...

Страница 2: ...nections to and from the product are neither subject to potentially des tructive mechanical impact nor present any risk of stumbling or other accident risk to people Audio equipment may generate sound...

Страница 3: ...ized recycling stations Unpacking Please check that the box contains the following items Main parts 1 pc RDP 2200 main unit 1 pc Mains cable 1 pc Operation manual If any part is missing please contact...

Страница 4: ...PAGE 3 Controls and Connections 8 1 7 2 3 5 4 USER MANUAL RPD2200 COMPRESSOR LIMITER 10 9 30 13 15 19 22 17 20 23 25 6 14 18 26 11 16 21 24 27 12 28 29 37 33 34 36 32 35 31...

Страница 5: ...r external control OPERATING LEVEL switch This switch can be used to adapt to various operating levels i e to toggle between home recording level 10 dBV and studio level 4 dBu The level meters will be...

Страница 6: ...in path and thus avoids the pumping effect caused by high energy bass frequencies and their influence on the compression process COMPRESSOR ATTACK control This determines when the compression sets in...

Страница 7: ...tch with LED This switch adapts the de esser to the male switch pressed or female registers not pressed DE ESSER LEVEL DISPLAY This LED chain shows the attenuation within a range from 3 to 12 dB DE ES...

Страница 8: ...r mixer to a low level Set the audio output of any audio processor between the mixer and the amplifier s to a medium level if any such processors Turn up the volume controls of your amplifier s slowly...

Страница 9: ...ctions red shield black tip sleeve tip sleeve red tip shield sleeve red tip black sleeve shield uncon 3 1 2 plug side 3 1 2 cable side red 2 black 3 shield 1 red 2 shield 1 3 2 3 1 3 1 2 3 1 2 cable s...

Страница 10: ...try s of purchase requirements on the function of the electronic circuitry we hence have to limit the warranty on such electro mechanical parts to 90 days from the date of purchase In many cases malfu...

Страница 11: ...PAGE 10 USER MANUAL RPD2200 COMPRESSOR LIMITER...

Страница 12: ...N60065 2014 ROHS2 Directive 2011 65 EU and is marked as follows Authorized Signature Place and date of issuing www hill audio com Hill Audio products are developed manufactured and distributed by Adel...

Отзывы: