Thermal & Optical Bi-spectrum Network Camera User Manual
21
Chapter 4 Event and Alarm
This part introduces the configuration of events. The device takes certain response to triggered
alarm.
4.1 Set Alarm Input
Alarm signal from the external device triggers the corresponding actions of the current device.
Before You Start
Make sure the external alarm device is connected. See Quick Start Guide for cable connection.
Steps
1. Go to Configuration → Event → Basic Event → Alarm Input.
2. Check Enable Alarm Input Handling.
3. Select Alarm Input NO. and Alarm Type from the dropdown list. Edit the Alarm Name.
4. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for
setting linkage method.
5. Click Copy to... to copy the settings to other alarm input channels.
6. Click Save.
4.2 Set Exception Alarm
Exception such as network disconnection can trigger the device to take corresponding action.
Steps
1. Go to Configuration → Event → Basic Event → Exception.
2. Select Exception Type.
HDD Full
The HDD storage is full.
HDD Error
Error occurs in HDD.
Network
Disconnected
The device is offline.
IP Address Conflicted The IP address of current device is same as that of other device in the
network.
Illegal Login
Incorrect user name or password is entered.
3. Refer to Linkage Method Settings for setting linkage method.
4. Click Save.
Содержание UD28093B
Страница 1: ...Thermal Optical Bi spectrum Network Camera User Manual ...
Страница 19: ...Thermal Optical Bi spectrum Network Camera User Manual 7 Figure 3 1 Thermography Configuration Flow Chart ...
Страница 41: ...Thermal Optical Bi spectrum Network Camera User Manual 29 Note Only certain camera models support the function ...