4
Configuration
Device Wiring
Attendance Configuration
2
User Management
1
Note:
The external power supply and the access control terminal should use the same GND cable.
Manage User:
In the New (New User) interface, enter the new user ID No., the user name, the card No. Register the fingerprint, set the password, select the department, set the user permission, select schedule template, set
the authentication mode and set the duress card. Save the parameters to confirm adding.
Configure the shift via the device. You are able to schedule shift by department or by individual depending on the user property. The working flows are as follows:
Scheduling Shift by Department:
Add User (See Step 1) - Edit Department - Configure Shift - Add Holiday - Configure Shift Schedule (by Department).
Edit Department:
Select a department to edit in the department list. Select “Edit”and edit the department name. Save the parameters.
Configure Shift
Normal Shift: In the Normal Shift page, configure the attendance rule, the normal shift attendance. Save the parameters to confirm setting.
Man-Hour Shift: In the Man-Hour Shift page, configure the man-hour shift parameters. Save the parameters to confirm setting.
Add Holiday
In the New (New Holiday) interface, enter the holiday No, the holiday name, the holiday start time and the holiday end time. Save the parameters.
Configure Shift Schedule
Schedule Shift by Department: Select a department to configure in the By Dept. (Schedule by Department) interface. Configure the shift, the start date, the end date and the holiday. Save the parameters.
Schedule Shift by Individual: Select New Individual Shift in the By Indiv. (Schedule by Individual) interface. Select a person to schedule in the New Individual Shift page. Configure the shift, the schedule start date and the
end date. Save the parameters.
External Device Wiring Overview
Attendance Report
Plug the USB flash drive in the device. Enter Attendance - Report, select a table type, create a device ID, select start date and end date. Press OK to export.
The device will automatically check the USB flahs drive memory. If there is no enough space for exporting, a prompt will be popped up. You can configure the record over threshold prompt and record delete
pafarmeters in the System page.
Record over Threshold Pop up Prompt (%):
If the attendance record memory reaches the configured value, the system pops up a prompt to remind you. If configure the threshold to 99%, the system will pop
up a prompt to remind you to delete the attendance data when the capacity reaches the threshold.
The available value: 1 to 99.
Record Delete:
When the function is enabled, the terminal will delete the first 3000 attendance records when the memory is full, in order to save the new attendance records. By default, the function is enabled. See
Section 5.2 Attendance Record Delete Rule
in
User Manual of Fingerprint Time Attendance Terminal
.
5
Scheduling Shift by Individual:
Add User (See Step 1) - Configure Shift - Add Holiday - Configure Shift Schedule (by Individual).
User Management and Attendance Configuration are two main parts of the Access Control Terminal.
Regulatory Information
This product and - if applicable - the supplied accessories too are
marked with "CE" and comply therefore with the applicable
harmonized European standards listed under the RE Directive
2014/53/EU, the EMC Directive 2014/30/EU, the RoHS Directive
2011/65/EU.
2012/19/EU (WEEE directive): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local
supplier upon the purchase of equivalent new equipment, or
dispose of it at designated collection points. For more information
see:
www.recyclethis.info
2006/66/EC (battery directive): This product contains a battery that
cannot be disposed of as unsorted municipal waste in the European
Union. See the product documentation for specific battery
information. The battery is marked with this symbol, which may
include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg).
For proper recycling, return the battery to your supplier or to a
designated collection point. For more information see:
www.recyclethis.info
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two
conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence.
L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible
d'en compromettre le fonctionnement.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum
(or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users,
the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more
than that necessary for successful communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie
Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut
choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas
l'intensité nécessaire à l'établissement d'une communication satisfaisante.
This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.
Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur et votre corps.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operation.
EU Conformity Statement
FCC Information
Please take attention that changes or modification not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
FCC compliance:
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.
Use only power supplies listed in the user instructions:
Model
Manufacturer
Standard
DSA-12PFT-12FUK 120100
DSA-12PFT-12FAU 120100
DSA-12PFT-12FIN 120100
DSA-12PFT-12FUS 120100
DSA-12PFT-12 FBZ 120100
Dee Van Enterprise Co., Ltd.
BS
Dee Van Enterprise Co., Ltd.
Dee Van Enterprise Co., Ltd.
Dee Van Enterprise Co., Ltd.
Dee Van Enterprise Co., Ltd.
AS
NBR
IEC
IS
Door Magnetic Contact
Gourp B
Gourp C
B1
B2
B3
B4
B5
B6
C1
C2
Black
Red
Yellow
View License:
You can view the device License via the website:
http://opensource.hikvision.com/Home/List?id=46
Scan the QR code to get the
user manual for detailed
information.
Note that mobile data
charges may apply if Wi-Fi is
unavailable.
Other Settings
3
Manage Data:
Enter System - Data page, and select Delete Event Only, Delete Attendance Data Only, Delete User Only, or Clear Permisison to manage the system data.
Factory Defualts:
Enter System - Reset page, and select Factory Defaults. All device parameters will restore to the factory settings.
Default Settings:
Enter System - Reset page, and select Default Settings. All parameters, excluding the communication parameters, and the remote user management paramters, will restore to factory settings.
Upgrage Device:
Plug an USB flash drive to the device USB falsh drive interface. Tap System - Upgrade and tap OK to upgrade the device. The device will reboot automatically after upgrading is completed.
Notes:
1. The upgrading file should be in the root directoy in the USB flash drive.
2. The upgrading file name should be digicap.dav.
3. Do not power off when device is upgrading.
External Device Wiring Terminal Description
Line
Group
No.
Func
ti
on
Color
Terminal
Name
Descrip
ti
on
Line
Group A
A1
Power Input
Red
+12V
12V DC Power Supply
A2
Black
GND
GND
Line
Group B
B1
Lock
White
/
Purple
NC
Lock Wiring
B2
White
/
Yellow
COM
B3
White
/
Red
NO
B4
Yellow
/
Green
SENSOR
Door Contact Signal
Input
B5
Black
GND
GND
B6
Yellow
/
Grey
BUTTON
Exit Door Wiring
Line
Group C
C1
Door Bell
Red
BELL+
Door Bell Wiring
C2
Yellow
BELL-
CAUTION
RISK OF EXPLOSION IF BATTERY IS
REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES
ACCORDING TO THE INSTRUCTIONS.
Hik-Connect:
You can operate the device via the Hik-Connect mobile client.