
Area Scan Machine Vision USB 3.0 Camera User Manual
31
continuously based on the configured frame rate. SingleFrame refers to outputting
only one image, as shown in Figure 3-14.
Figure 3-14
Internal Trigger Mode
3.4.2
External Trigger Signal and Working Mode
Purpose:
The signal for the camera to acquire external trigger signal includes the software
trigger signal and the signal from external level.
Under the external trigger signal mode, the camera can output images according to
single frame mode, burst mode, PWM mode and any other working modes.
Software trigger mode
Support software trigger mode. When setting software trigger mode, the client
software will send command to the camera to capture and transfer images.
Click Acquisition Control in the attribute list and select Trigger Mode. Choose On to
open trigger mode. Select Trigger Source and choose Software to switch to the
software external trigger status. Click Execute in Trigger Software to trigger image
acquisition, as shown in Figure 3-15.