HIKVISION Pyronix MC1/SHOCK-WE Скачать руководство пользователя страница 1

GREEN =

CALIBRATED

IMPACT

RED =

ANY IMPACT 

FORCE

Wireless Magnetic Contact & Shock Sensor

LEARN WIRELESS

DEVICE?

Learn Inputs?

Learn Devices?

Input 01

Available   [01]

Input 02

Available   [02]

Learning...

Input Learnt!

PRESS

HOLD

RELEASE

USE SUPPLIED

No 8

countersunk

self tapping 

screw

Input Learnt!

>5s

START

>5s

PROGRAM INPUTS?

Input      [01]

Input 01

Input Type [07]

Intruder

Input Areas

         [ABCD]

Input Areas

Any         [0]

CHANGE INPUTS?

Input      [01]

Input 02

Input Type [06]

Intruder

Input Areas

         [ABCD]

Input Areas

Any         [0]

5s

LEDs

LEDs

No. 6.

Pan Head 

Screw

DISABLED

ALARM

TAMPER

ENABLED

1s

....10m

1

2

Connect this jumper to 

enter calibration mode

Strike surface to simulate minimum impacts you want the

sensor to detect. Ensure the LEDs go red and then green.

3

Very carefully remove

the jumper connection

4

5

The Shock will now be in ‘Test Mode’ for 

10mins & the LEDs will indicate the following:

If the sensitivity needs adjustment 

wait 2 seconds & go back to step 

D1

1

2

3

TAMPER

2

3

1

Ensure that the magnetic

contact is enabled 

Unclip the magnet cover 

and use the correct screws

Ensure that the magnet is aligned 

with the detector using the arrows.

After the 10min calibration period all 

activations illuminate the blue LED

DISPLAY BLUE ALARM LED?

MAGNET

SHOCK

Learning...

Remove 

Battery 

Tab

WIRELESS DEVICE

CONTROL?

Control Inputs?

Learn Devices?

Input 01

Available   [01]

Learning...

PRESS

HOLD

RELEASE

.... .   .

DIAGNOSTICS?

Wireless Range &

Battery Status?

Signal Strength?

Wireless Inputs?

33--------------

----------------

300s

Please Wait

299

DIAGNOSTICS?

View Wireless

Device Status?

Signal Strength?

Inputs?

33--------------

----------------

300s

Please Wait

299

(Input 

types 

shown are

just 

examples)

No. 8    RSCW140

....10m

....10m

....10m

If replacing 

battery, insert

in direction

shown

RINS1638

 Document SAP: 102014992-11

Partcode: MC1/SHOCK-WE   

 

+44(0)333 444 1280 (UK)

 [email protected]

 

www.pyronix.com

Pyronix Limited, Pyronix House, Braithwell Way, Hellaby, Rotherham, S66 8QY, UK

Installation notes

It is recommended the device is learned at the control panel. A signal strength test 
should then be performed to select the most suitable location, ensuring optimum 
wireless range.

Installation Surfaces

Please note: The device can be mounted on typical building materials; such as wood, 
PVC, brick or metal etc. If you do encounter any problems with different surfaces, please 
contact [email protected] 

References

A. Learn wireless devices / wireless device control 

B. Diagnostics

C. Positioning the arrow

When fitting the device, the arrow on the inertia barrel must be installed one ‘notch’ to 
negative from directly vertical (as shown) and should not be altered unless instructed to 
by Technical Support. Once affixed in position, a ‘shock sensor calibration’ procedure 
should be performed to ensure optimal performance (as in section D).
Please note: If the sensitivity should require altering again, repeat the ‘shock sensor 
calibration’ procedure, do not change the orientation of the inertia barrel.

D.

 

Shock sensor calibration

To calibrate the activation force on the shock sensor,  a link must be fitted to the 
calibration header as shown. If the link is connected, but an activation force is not 
applied before disconnecting it, the device will be set to the highest sensitivity. If an 
activation force is applied with the link fitted (e.g. hitting your hand against the window 
frame), the Shock will be calibrated at this custom sensitivity as soon as the link is 
removed. 

 

E. Magnetic contact installation        

F. Program / change zones
G. External zone wiring

Specification

Battery

Type: 3.0V CR123A Lithium Battery.  Threshold: 
2.2V +/- 5% at 25°C. Life: Up to 2 Years
Battery (type C according to EN 50131-6): 
Current: 5μA (quiescent)/ 65mA (transmitting)

Wireless Transmission Frequency

868MHz FM Transceiver Narrow Band

Transmission Method

Fully encrypted rolling code

LED Indication

Green=MC. Red=Shock.
(Signal,Battery,Alarm,Tamper).

Colour and Casing

White. 2mm ABS

Tamper protection

Front and rear case tamper with 1 external zone 
tamper (normally closed).

Temperature

Storage: -20°C to 50°C
Certified: -10°C to 40°C
Nominal: -10°C to 50°C

Dimensions and weight (W x H x D)

Device: 130 x 30 x 35mm
Magnet: 56 x 17 x 12.7mm
Weight: 89g

Compatible with the Enforcer, PCX/EURO control panels with wireless expander, and UR2. Please see 
the control panel user, programming and quick set manuals for further information.

Important note

For operation of both the shock sensor and the magnetic contact, the software version of the control 
panel must be >V9.0 (UK), >V9.26(EXPORT) and hub V2.23 or greater. For use with wireless ZEM (V2.36 
or greater). Older software versions will only allow the shock zone to be learnt. Hom V2.00 & 
V2.10 are also compatible.
Please note: Both shock and contact must be learnt to the same wireless hub (both to the control 
panel or both to the ZEM, not one to each or across multiple ZEMs).

Battery information

The batteries supplied have been chosen to provide long service life whilst, for safety reasons, having limited 

output current.
The battery is protected on purchase by a piece of plastic that must be removed for operation. When disposing 

of the product, the battery must be removed and disposed of separately in accordance with local regulations.

Warranty

This product is sold subject to our standard warranty conditions and is warranted against defects in workmanship for a 

period of two years (battery excluded). In the interest of continuing care and design, Pyronix Ltd reserves the right to 

amend specifications, without giving prior notice. Visit www.pyronix.com/warranty for more information.

Product warning information

For electrical products sold within the European Community. At the end of the electrical products life, it should not be 
disposed of with household waste. Please recycle where facilities exist. Check with your Local Authority or retailer for 
recycling advice in your country.To prevent possible damage to components, any static charge on your body needs to 
be eliminated before touching the inside of the unit. This can be accomplished by touching some grounded/earthed 
metallic conductor such as a radiator/pipework immediately before replacing the batteries.

EN50131-2-6:2008

EN50131-5-3:2005+A1:2008

PD6662:2017

Security Grade (SG) 2

Environmental Class (EC) II

X+

X-

Z-

Z+

Y

Spacers available if required MC1S/SPACER and MC1S/SPACERRB

+

-

Содержание Pyronix MC1/SHOCK-WE

Страница 1: ... the link is connected but an activation force is not applied before disconnecting it the device will be set to the highest sensitivity If an activation force is applied with the link fitted e g hitting your hand against the window frame the Shock will be calibrated at this custom sensitivity as soon as the link is removed E Magnetic contact installation F Program change zones G External zone wiri...

Страница 2: ...s sur les piles Entretoises disponibles si nécessaire MC1S SPACER WE et MC1S SPACERB WE Caractéristiques techniques Informations d avertissement concernant le produit Garantie Nous vous recommandons de connecter le MC1 SHOCK WE au niveau du panneau de contrôle Vous devez ensuite exécuter un test de puissance du signal pour vous assurer que vous avez bien choisi l emplacement le plus adapté et ains...

Страница 3: ...Aproximar Intrusão Espera Intrusão Espera Intrusão Espera Intrusão Espera Intrusão Espera Distância em ferro Distância no ar Sinal Mensagem EN50131 2 6 2008 EN50131 5 3 2005 A1 2008 PD6662 2017 Класс безопасности SG 2 Класс окружающей среды EC II Р У С С К И Й пояснения к схемам Примечания к установке Поверхности для установки Пояснения Информация об аккумуляторах При необходимости предлагаются пр...

Отзывы: