3)

 

Post the mounting template and keep it towards the outside of vehicle. Drill a hole on the 
vehicle for wiring, thread the camera’s cable through the hole and fix the camera to the top 
of the vehicle with screws. 

4)

 

Adjust the angle to make sure the lens is downward vertically and fix the lens. 

5)

 

Put the housing back and finish installation. 

2.4.2 Wiring and Power On 

 

Power on and configure the camera. Please note that the connection for mobile is different with 
conventional camera. 

1)

 

Power on the camera:

 It is no need to 

use the patch cord

 if the vehicle can adapt the joint 

directly. Otherwise, connect the patch cord which needs to order separately with camera’s cable or cut 

the power connector. The power adapt is suggested to access in the “Vehicle on Fire”, or it will cause 
the loss of counting.

 

 

 

2)

 

The signal of opening/closing door: It is a necessary parameter of algorithm, the connection 
configuration is different according to the type of the signal (Level Signal or Pulse Signal ) 

Level Signal: 

a)

 

Level Signal transfers on two-wire cord, which will be changed by the door status.

 

b)

 

Please use the multi-meter to measure the level value, which corresponds to the state of the door. 
For the device, 0-3.5V will be regarded as low level and above 6V will be regarded as high level. 

The maximum accessible voltage is 30V.

 

c)

 

Connect the signal of opening/closing door to ALARM IN1 and GND of device. 

Pulse Signal: 
a)

 

Pulse Signal is composed of three-wire which are used for opening/closing door and 
GND. It will output a pulse signal from each wire when opening and closing the door. 

b)

 

Please  use the multi-meter  to  measure  the  pulse voltage.  0-3.5V  will  be  regarded  as 
low pulse and above 6V is high pulse. The maximum accessible voltage is 30V. 

c)

 

Connect the pulse signal wire of opening door with ALARM IN1. 

d)

 

Connect the pulse signal wire of closing door with ALARM IN2. 

e)

 

Connect the 2 GNDs with the GND of car. 

Содержание iDS-2XM6810F-I/C

Страница 1: ...Configuration Installation Guidance of Mobile Dual lens People Counting Camera...

Страница 2: ...ower On 10 Chapter 3 Configuration 11 3 1 Configuration Step 11 3 1 1 Image Configuration 11 3 1 2 Alarm Input Configuration 11 3 1 3 485 Configuration It is needed only when DVR is used 12 3 1 4 Peop...

Страница 3: ...achieve high precision people counting It greatly improves the statistical accuracy rate and optimizes the adaptive capacity of camera which includes anti vibration capability radiation protection ca...

Страница 4: ...m ordinary cameras Please read this chapter carefully before installation and the below are some key points should be considered Patch cord should be ordered in advance Proper installation position sh...

Страница 5: ...ion proof silicone pad Hexagonal screwdriver and screws Include 4 expansion screws and self tapping screws Mounting Template Device patch cord Ordered separately SAP code 101505587 68 mobile dual lens...

Страница 6: ...loss of accuracy What is Entry Exit Area for bus it s near the door where standing is forbidden region of the first step usually for coach it s the combined region of the first step and the second st...

Страница 7: ...table of Lens Height Maximum Detection Width is shown as below Lens Height m Maximum Detection Width m 2 1 0 9 2 2 1 1 2 3 1 3 2 4 1 5 2 5 1 8 2 6 2 0 2 7 2 2 2 8 2 4 2 9 2 7 3 0 2 9 The Correspondin...

Страница 8: ...side the ground The installation and the live view pictures are shown as below Installation position for bus 2 3 3 Coach Solution For coach it has some steps and the first step isn t suitable to be se...

Страница 9: ...and Wiring Step 2 4 1 Installation Step Choose proper installation position and mount the camera according the following steps 1 Remove the housing by the hexagonal screwdriver 2 Thread cable through...

Страница 10: ...ry parameter of algorithm the connection configuration is different according to the type of the signal Level Signal or Pulse Signal Level Signal a Level Signal transfers on two wire cord which will b...

Страница 11: ...gh but not overexposure 2 Make sure device time is correct and then disable OSD 3 1 2 Alarm Input Configuration Alarm input configuration is needed and the configuration method is different according...

Страница 12: ...save the configuration 3 Set Alarm Input No as A 2 If the alarm is triggered by high pulse set Alarm Type as NO if triggered by low pulse set Alarm Type as NC Then save the configuration 3 1 3 485 Con...

Страница 13: ...Exit area to the camera and click Calibrate then a red frame and a yellow line will automatically appear in the image The red frame is for counting and the yellow line is for detection Make sure the r...

Страница 14: ...ea Confirm the nodes which the supported maximum number is 10 by left mouse button and click right mouse button to confirm the drawn area 6 Save it after finishing the configuration Set the Arming sch...

Страница 15: ...will keep counting all the time and will influence the accuracy rate RS 485 data transmission isn t supported under this mode b Triggerd by Alarm Input It controls the open closed status via accessing...

Страница 16: ...ormation in the live view image Enter Leave Enter Leave and None are optional 3 Display Rule Info on Stream It will display the ID number and height information of tracking people after enabling it Th...

Страница 17: ...tus of the camera There are three types optional Counting Stop counting Pause counting You can click Refresh button to refresh the status Counting Count normally Stop counting Disable people counting...

Страница 18: ...Always do the operation with caution Deleted data cannot be restored 3 2 Configuration Instruction 3 2 1 Entry Exit Area Configuration 1 Keep the door open 2 Generally Entry Exit Area is set as the fi...

Страница 19: ...the counting area 4 The direction must point to the inside of vehicle 3 3 Statistics Results 1 Enter Application People Counting 2 Choose a Report Type Daily Weekly Monthly Annual Report are selectabl...

Страница 20: ...rules and configuration information during the debugging process 4 1 Screenshot of Configuration Save the screenshot of Basic Information Alarm input and Rule of people counting 4 2 Internal Paramete...

Страница 21: ...2 Click Product Related BV Correct...

Страница 22: ...4 3 Get Dual lens Video 1 Access the camera via web browser 2 Enter Configuration Video Audio Video 3 Set stream type as Sub Stream and modify the Max Bitrate to 8012Kbps then save it...

Страница 23: ...witch the stream type to Sub Stream in the live view interface The image will be displayed as a montage image which includes the upper and lower image Click Start Recording button to record then save...

Отзывы: