HIKVISION EPI-4215-DE3 Скачать руководство пользователя страница 5

 

 

QSG EPI-4215-DE3 030518NA 

 

If smoke, odor or noise rise from the device, turn off the power at once and unplug 

the power cable, and then contact the service center.   

 

If the product does not work properly, contact your dealer or the nearest service 

center. Never attempt to disassemble the 

speed dome

 yourself. (We shall not assume 

any responsibility for problems caused by unauthorized repair or maintenance.) 

 

Cautions

 

 

If the 

speed dome

 fails to synchronize local time with that of the network, you need 

to set up 

speed dome

 time manually. Visit the 

speed dome

 (via web browser or client 

software) and enter system settings interface for time settings. 

 

Make sure the power supply voltage is correct before using the 

speed dome

 

Do not drop the 

speed dome

 or subject it to physical shock, and do not expose it to 

high electromagnetism radiation. Avoid installation on vibrations surface or places 
subject to shock (ignorance can cause device damage). 

 

Do not touch senor modules with fingers. If cleaning is necessary, use clean cloth with 

a bit of ethanol and wipe it gently. If the 

speed dome

 will not be used for an extended 

period, replace the lens cap to protect the sensor from dirt. 

 

Do not aim the 

speed dome

 at the sun or extra bright places. Blooming or smearing 

may occur otherwise (which is not a malfunction), and affect the endurance of sensor 
at the same time.   

 

The sensor may be burned out by a laser beam, so when any laser equipment is in 

using, make sure that the surface of sensor will not be exposed to the laser beam. 

 

Do not place the 

speed dome

 in extremely hot, cold, dusty or damp locations, and do 

not expose it to high electromagnetic radiation.   

 

To avoid heat accumulation, good ventilation is required for operating environment.   

 

Keep the 

speed dome

 away from liquid while in use. 

 

While in delivery, the 

speed dome

 shall be packed in its original packing, or packing of 

the same texture. 

 

Improper use or replacement of the battery may result in hazard of explosion. Replace 

with the same or equivalent type only. Dispose of used batteries according to the 
instructions provided by the battery manufacturer. 

 

Содержание EPI-4215-DE3

Страница 1: ...Network Speed Dome Camera EPI 4215 DE3 Quick Start Guide...

Страница 2: ...ome The Manual includes instructions for using and managing the product Pictures charts images and all other information hereinafter are for description and explanation only The information contained...

Страница 3: ...ide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not instal...

Страница 4: ...asure is divided into Warnings and Cautions Warnings Neglecting any of the warnings may cause serious injury or death Cautions Neglecting any of the cautions may cause injury or equipment damage Warni...

Страница 5: ...senor modules with fingers If cleaning is necessary use clean cloth with a bit of ethanol and wipe it gently If the speed dome will not be used for an extended period replace the lens cap to protect...

Страница 6: ...me 9 2 1 1 In Ceiling Mounting 9 3 Speed Dome LAN Configuration 12 3 1 Wiring 12 3 2 Activating the Speed Dome 13 3 3 Modifying the IP Address 15 4 Accessing via Web Browser 16 1 Hik Connect 18 1 1 En...

Страница 7: ...e 1 1 Overview of EPI 4215 DE3 Speed Dome 1 2 Cable Interfaces The speed dome cable interfaces are shown in Figure 1 2 The cables can be differentiated by color Refer to the labels attached to the cab...

Страница 8: ...t all required parts are included Notes Do not touch the bubble This might cause image blur Do not power the speed dome on until installation is finished To ensure the safety of personnel and equipmen...

Страница 9: ...ace above the ceiling must be more than 250 mm The thickness of the ceiling must range from 5 mm to 40 mm The ceiling must be strong enough to withstand more than four times the weight of the speed do...

Страница 10: ...emory Card Slot 3 Drill screw holes in the ceiling 1 Attach the drill template to the ceiling where you want to install the speed dome 2 Cut a hole and drill screw holes according to the drill templat...

Страница 11: ...Figure 2 5 Install the Toggle Bolts 5 Install the speed dome to the ceiling 1 Align the toggle bolts with the screw holes on the ceiling 2 Push the speed dome to the mounting hole on the ceiling 3 Rot...

Страница 12: ...kage strengthen your own network protection If the product does not work properly contact your dealer or the nearest service center for help To ensure the network security of the speed dome we recomme...

Страница 13: ...e activation 3 2 1 Activation via Web Browser Steps 1 Power on the speed dome Connect the speed dome to your computer or the switch router that your computer connects to 2 Input the IP address into th...

Страница 14: ...nfirm the password 5 Click OK to activate the speed dome and enter the live view interface 3 2 2 Activation via SADP SADP software is used for detecting the online device activating the device and res...

Страница 15: ...nd 4 Click Activate to save the password Note You can check whether the activation is completed on the pop up window If activation failed make sure that the password meets the requirements and try aga...

Страница 16: ...IP address modification Batch IP address modification is supported by SADP Refer to the SADP user manual for details 4 Accessing via Web Browser System Requirement Operating System Microsoft Windows...

Страница 17: ...roperly Delete unnecessary accounts and user operator permissions Note The device IP address gets locked if the admin user performs seven failed password attempts five attempts for the user operator 4...

Страница 18: ...er via SADP software or a Web browser 1 2 Enable Hik Connect Service via SADP Software Steps 1 Check the Enable Hik Connect checkbox 1 For the Activate the Device page that appears during camera activ...

Страница 19: ...Platform Access Configuration Web 3 Set the Platform Access Mode to Hik Connect 4 Check the Enable checkbox 5 Click and read the Terms of Service and Privacy Policy in the pop up window 6 Create or ch...

Страница 20: ...on your camera Forgotten verification codes can be recovered in the Platform Access configuration page via the web browser 4 Follow prompts to set up the network connection and add the camera to your...

Страница 21: ...QSG EPI 4215 DE3 030518NA 21...

Отзывы: