HIKVISION DS-PDSMK-E-WE Скачать руководство пользователя страница 4

4

Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

1. Check Signal Strength
Enter the signal checking mode by opera�ng on the control panel.
Strong Signal - Good for installa�on
Medium Signal - Ok for installa�on
Weak Signal - Not proper for installa�on
Lost Signal - Not proper for installa�on

4

Installa�on

Signal Strength Test

2. Install the Detector.

Secure the moun�ng plate on the wall with supplied screws.

Using the two screws and plastic wall plugs (all supplied), attach the bracket to the wall.
Line up the slot of the bracket and the smoke detector. Push the smoke detector onto the mounting bracket and turn it clockwise to fix it into place. Pull
onward on the smoke detector to make sure it is securely attached to the mounting bracket.

CAUTION

: This smoke detector comes with cover latches that

will prevent the smoke detector cover from closing if battery is
not installed. This tells you that the smoke detector will not
work until a new battery is properly installed.

NOTE

: Alarm horn will beep once with Green LED flashing 1

times after the detector is installed with battery and mounted
with bracket 2 seconds. This means the smoke detector is
working normally and also indicates that the battery is
positioned properly. Close cover, and then press the test
button. The horn should sound a loud, pulsating alarm. This
means the unit is working properly.

5

Features

STANDBY MODE

Green LED flashing once 48 seconds means that smoke detector in Standby mode. When pressing the test button of

smoke

detector in standby mode,

Red LED flashing once a second and temporal three tone, it means the smoke detector can be normally operated.

ALARM MODE

Smoke Alarm:

Red LED flashing 3 times and horn emit 3 tones every 4 second.

SILENCE FEATURE

The silence features can temporarily mute an alarm for up to 8 minutes. To use this feature, press test/silence button of smoke detector when it alarms.

However, if the temperature is still at alarming level after 8 minutes of silence, the unit will re-alarm immediately.

HUSH FEATURE

The hush features can temporarily mute a warning of malfunction for up to 1 hour. To use this feature, when smoke detector occurs warning
(malfunction), press test button can be mute 1 hour.

In hush warning press test button, the smoke detector back audible warning.