HIKVISION DS-PDPC12P-EG2-WE Скачать руководство пользователя страница 2

1. Check Signal Strength

Enter the signal checking mode by operating on the control panel. Trigger the detector.

Solid Green for 3 s - Strong Signal 

Solid Orange for 3 s - Medium Signal

Solid Red for 3 s - Weak Signal

Red light flashes for 3S - Failure

2. Check the installation environment

Note: make the device power off, hold the tamper switch and then power on for re-enrollment synchronously.
The distance between the detector and AXPRO should be less than 50 cm.

3

Installation

2

Enroll the Peripheral with QR and serial No.

1. In the APP, tap the icon "+"and scan the QR code or serial No. on the peripheral.

2. Loosen the screw and remove rear panel.

3. Power on the peripheral, and it will be automatically enrolled to the control panel.

Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

7      Times

xxxx

Device

Signal Strength Test

2

Содержание DS-PDPC12P-EG2-WE

Страница 1: ...ote The enrollment progress will be completed in 3 to 10 seconds normally 1 Enroll the Peripheral Locally 1 Log in to the APP Store download and install the App 2 Power on the security control panel 3...

Страница 2: ...nd then power on for re enrollment synchronously The distance between the detector and AXPRO should be less than 50 cm 3 Installation 2 Enroll the Peripheral with QR and serial No 1 In the APP tap the...

Страница 3: ...ing plate shall not be damaged Make sure there is no obstacle sheltering the LENs and IR light with Screws a Knock out the screw holes on the rear panel with the Sponge Tape Paste the device on the wa...

Страница 4: ...zhou 310052 China 10m 12m 1m 2m 4m 6m 8m 10m 12m 1m 2 1m 2m 4m 6m 8m 10m 12m 1m 2m 4m 6m 8m 85 9 a Detection Range 52 zones 4 planes Detector zones and planes The zones and plans of the PIRCAM are sho...

Страница 5: ...e the installation position is properly If the LED indicator is still o adjust the position of the detector within 3 min after the enrollment 5 Hold the tamper switch for 8 s and power the device on a...

Страница 6: ...e sun or extra bright places A blooming or smear may occur otherwise which is not a malfunction however and a ecting the endurance of sensor at the same time Improper use or replacement of the battery...

Страница 7: ...y and night Colour Black White Flash IR LED 1 IR LED LED range 12m Image type JPEG Image resolution 160x120 320x240 640x480 Images in series Up to 20 images Tamper protection Front Back LED indicator...

Отзывы: