HIKVISION DS-PDC15-EG2-WE Скачать руководство пользователя страница 6

7

Operation Caution and Device Maintenance

- All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention 

regulations and other related regulations in your local region.

- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. 

Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment 

damage).

- Please make sure that the power has been disconnected before you wire, install or dismantle the device.

- If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then 

please contact the service center.

- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. 

Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment 

damage).

- Do not place the device in extremely hot (refer to the specification of the device for the detailed operation 

temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation.

- The device for indoor use shall be kept from rain and moisture.

Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden 

(ignorance can cause fire danger).

- Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not 

a malfunction however), and affecting the endurance of sensor at the same time.

- Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or 

equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufactur-

er.

- Do not expose the device to the corrosive gas. Otherwise the equipment damage may occur. 

- Do not expose the device to the explosive situation.

6

Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

Function

Description

Sensitivity

Set the sensitivity of the detector.

Higher sensitivity makes the intruder easier 

to be detected.

Image Resolution

Set the resolution of the image.

Image in Series

Set the captured image number in series.

Swinger limit activation

Set the limit times of swinger activition .

Trigger Interval, sec

Set the interval of trigger, and the alarm 

message will not be repeated within the 

time.

LED

Turn On/Off the LED.

Polling Rate

Set the interval of heartbeat.

Signal Strength Test

Enter the test mode, and view the LED 

indication.

Detection Zone Test

Enter the test mode, and start walk test.

Zone Bypass

By pass the zone.

Capture

Capture picture manully.

Содержание DS-PDC15-EG2-WE

Страница 1: ...completed in 3 to 10 seconds normally 1 Enroll the Peripheral Locally 1 Log in to the APP Store download and install the App 2 Power on the security control panel 3 Log in the APP and tap the icon Sc...

Страница 2: ...tamper button and make the device power o and then power on for re enrollment 3 Installation 2 Enroll the Peripheral with QR and serial No 1 In the APP tap the icon and scan the QR code or serial No...

Страница 3: ...he installation the equipment including any associated mounting plate shall not be damaged with Screws a Knock out the screw holes on the rear panel with the Sponge Tape Paste the device on the wall w...

Страница 4: ...pliant Wall Bracket Fitting 4 Test Detector zones and planes The zones and plans of the PIRCAM are shown below Detection Range 6 3 18 zones 8 planes 4 Hangzhou Hikvision Digital Technology CO Ltd No 5...

Страница 5: ...ad Binjiang District Hangzhou 310052 China 6 Set up with App Function Zone Type Stay Arm Bypass Chime Enable Silent Zone Slide to green to enable the chime Slide to green to make the zone keep silent...

Страница 6: ...un light low ventilation or heat source such as heater or radiator is forbidden ignorance can cause re danger Do not aim the device at the sun or extra bright places A blooming or smear may occur othe...

Страница 7: ...to 40 C 14 F to 104 F EN Certi ed Storage temperature 20 C to 60 C 4 F to 140 F Operating humidity 10 to 90 Installation height 1 8 to 3m Dimension W H D 65 5mm 103mm 48 5mm Weight 128g Bracket Option...