background image

11

Specification

8

5

7

Functions

Operation Caution and Device Maintenance

- All the electronic operation should be strictly compliance with the electrical safety regulations, fire prevention regulations and other related
regulations in your local region.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment
installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).
- Please make sure that the power has been disconnected before you wire, install or dismantle the device.
- If smoke, odors or noise rise from the device, turn off the power at once and unplug the power cable, and then please contact the service
center.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation. Avoid the equipment
installation on vibrations surface or places subject to shock (ignorance can cause equipment damage).
- Do not place the device in extremely hot (refer to the specification of the device for the detailed operation temperature), cold, dusty or
damp locations, and do not expose it to high electromagnetic radiation.
- The device for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden (ignorance can cause fire
danger).
- Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not a malfunction however), and
affecting the endurance of sensor at the same time.
- Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only. Dispose of
used batteries according to the instructions provided by the battery manufacturer.
- Do not expose the device to the corrosive gas. Otherwise the equipment damage may occur.
- Do not expose the device to the explosive situation.

You can add two external inputs (each input can be set as NO\NC\TAMPER\Pulse) via the AX PRO client.
While Any of the two inputs generates an alarm event, the detector reports the alarm to the AX PRO. The LED keeps blue for 2 s.

4

Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China

Set Up with App

6

You can view the device status including temperature, signal intensity, battery level, lid, external input, etc.,on the device page.
Tap the

button to enter the settings page.

Formatting

1. Remove the battery.
2. Hold the TAMPER button and power the detector on at the same time.
The red LED flashes 3 time when the formatting is completed.

Disallowed field adjustable settings: None

Sensor

Omnidirectional electret microphone

Detection range

8m radius

Glass type

Float, Plate, Tempered, Wired, Laminated Leaded, Double glazing

Glass thickness

2.4mm to 6.4mm

Glass size

0.3m x 0.3m to 3m x 3m

External Inputs

2

Input options

Normal and Fast Sensitivity with Pulse Count

Programmable pulse count

Yes

Normal input sensitivity

300ms

Tamper protection

Front & Back

LED indicator

Blue(alarm)

Encapsulated plastic

Yes

Operating temperature

-10 °C to 55 °C (14 °F to 131 °F)
-10 °C to 40 °C (14 °F to 104 °F) Certified

Storage temperature

-20 °C to 60 °C (-4 °F to 140 °F)

Operating humidity

10% to 90%

Installation

Wall/Ceiling mount

Dimension (H × W × D)

107.0 mm x 38.8 mm x 24.5 mm

Weight

134 g

Wireless technology

Tri-X Wireless Technology

Environment temperature Indicator

Yes

2-way wireless communication

Yes

Transmission frequency

868MHz

Frequency hopping

Multichannel transmisstion

Signal strength indicators

Yes

RF range

1.6Km (free space)

Enrolling methods

Power up, Remote ID, QR code

Battery

CR123A x 2 (included)

Standard battery life

3 years

Содержание DS-PDBG8-EG2-WE

Страница 1: ...E and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2014 30 EU RE Directive 2014 53 EU the RoHS Directive 2011 65 EU replacement of a battery with an incorrect type that can defeat a safeguard for example in the case of some lithium battery types disposal of a battery into fire or a hot oven or mechanically crushing or cutting of a battery that c...

Страница 2: ...er on the peripheral and it will be automatically enrolled to the control panel 1 In the APP tap the icon and scan the QR code or serial No on the peripheral 2 Loosen the screw and remove rear panel 3 Power on the peripheral and it will be automatically enrolled to the control panel 3 Test 2 Hangzhou Hikvision Digital Technology CO Ltd No 555 Qianmo Road Binjiang District Hangzhou 310052 China xxx...

Страница 3: ...el on the wall with the sponge tape Note To make the TAMPER work properly the thickness of the sponge tape should be no more than 1mm Installing with sponge tape is non EN compliant Close the front and the rear panel Note You should install the sensor and the magnetic stick at the door or window s edge Make sure they are aligned with the door or window s edge 4 Installation Method 1 Method 2 optio...

Страница 4: ...structions provided by the battery manufacturer Do not expose the device to the corrosive gas Otherwise the equipment damage may occur Do not expose the device to the explosive situation You can add two external inputs each input can be set as NO NC TAMPER Pulse via the AX PRO client While Any of the two inputs generates an alarm event the detector reports the alarm to the AX PRO The LED keeps blu...

Отзывы: