Swing Barrier
·
Quick Start Guide
18
Chapter 4
Device Settings
Purpose:
After installation and wiring completed, you should set the barriers closed position (study mode)
before entering the working mode.
You can also set the passing mode and memory mode, pair the remote control, initialize the
hardware, switching between RS-485 communication mode and RS-232 communication mode, and
view relay output NO/NC diagram by setting the DIP switch.
Study Mode: The barrier will learn the closed position.
Normal Mode: The device will work properly. The barrier position configured in study mode is
the closed position when the device is working normally.
Passing Mode: There are 9 passing modes, including controlled bi-direction, controlled
entrance and prohibited exit, controlled entrance and free exit, free bi-direction, free entrance
and controlled exit, free entrance and prohibited exit, prohibited bi-direction, prohibited
entrance and free exit.
Memory Mode: By default, the memory mode is enabled. When multiple cards are swiped and
authenticated, it allows multiple persons passing through the lane. When it counts the passing
people number is equal to the card swiped times, or no person passing through the lane after
the last person passing, the barriers will be closed.
Note:
You can also set the DIP switch to control the action of swiping card to open the barrier in
alarm area, entrance and exit controlling type, remote control pairing, etc. For details about the
DIP switch value, see Appendix A DIP Switch Descriptions.
4.1
Setting Closed Position
Purpose:
Enter the study mode through DIP switching to set the closed position of the device barrier.
Steps:
1.
Set The No.1 and No.2 switches of the 8-digit DIP Switch on the master lane controlling board
by referring the following figure to enter the study mode.
2.
Adjust the closed position of the barrier.
3.
Power on the device.
The device will remember the current position (closed position) automatically.
4.
Power off the device.
5.
Set the No.1 and No.2 switches of the 8-digit DIP Switch on the master lane controlling board
by referring to the following figure.
Содержание DS-K3B601-L Series
Страница 1: ...Swing Barrier Quick Start Guide...
Страница 16: ...Swing Barrier Quick Start Guide 8 3 4 3 Main Control Board Terminal Description...
Страница 23: ...Swing Barrier Quick Start Guide 15 Entering Wiring Exiting Wiring...
Страница 25: ...Swing Barrier Quick Start Guide 17...
Страница 38: ...Swing Barrier Quick Start Guide 30 UD08976B B...