HIKVISION DS-K2M061 Скачать руководство пользователя страница 4

Safety Instruction

Dangers

• The socket-outlet shall be installed near the equipment and shall be easily accessible.

• An all-pole mains switch shall be incorporated in the electrical installation of the building.

• Do not connect several devices to one power adapter as adapter overload may cause over-heat

or fire hazard.

• If smoke, odors or noise rise from the device, turn off the power at once and unplug the power

cable, and then please contact the service center.

• Shock hazard! Disconnect all power sources before maintenance.

• If the product does not work properly, please contact your dealer or the nearest service center.

Never attempt to disassemble the device yourself. (We shall not assume any responsibility for

problems caused by unauthorized repair or maintenance.)

Cautions

• The equipment has been designed, when required, modified for connection to an IT power

distribution system.

• This equipment is suitable for mounting on concrete or other non-combustible surface only.

• The serial port of the equipment is used for debugging only.

• • Install the equipment according to the instructions in this manual.

• To prevent injury, this equipment must be securely attached to the floor/wall in accordance

with the installation instructions.

• No naked flame sources, such as lighted candles, should be placed on the equipment.

• Do not place the device in extremely hot (refer to the specification of the device for the detailed

operating temperature), cold, dusty or damp locations, and do not expose it to high

electromagnetic radiation.

• The device cover for indoor use shall be kept from rain and moisture.

• Exposing the equipment to direct sun light, low ventilation or heat source such as heater or

radiator is forbidden (ignorance can cause fire danger).

• Please use a soft and dry cloth when clean inside and outside surfaces of the device cover, do

not use alkaline detergents.

• Please keep all wrappers after unpack them for future use. In case of any failure occurred, you

need to return the device to the factory with the original wrapper. Transportation without the

original wrapper may result in damage on the device and lead to additional costs.

DS-K2M061 Secure Door Control Unit User Manual

iii

Содержание DS-K2M061

Страница 1: ...DS K2M061 Secure Door Control Unit User Manual...

Страница 2: ...HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL CONSEQUENTIAL INCIDENTAL OR INDIRECT DAMAGES INCLUDING AMONG OTHERS DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION OR LOSS OF DATA CORRUPTION OF...

Страница 3: ...device with facial recognition features biometrics data is stored in your device with encryption method for fingerprint device only fingerprint template will be saved which is impossible to reconstruc...

Страница 4: ...of the equipment is used for debugging only Install the equipment according to the instructions in this manual To prevent injury this equipment must be securely attached to the floor wall in accordanc...

Страница 5: ...Available Models Product Name Product Model Secure Door Control Unit DS K2M061 DS K2M061 Secure Door Control Unit User Manual iv...

Страница 6: ...2 1 Cable Interface Description 3 2 2 Wiegand Interface Description 4 Chapter 3 Wiring Description 5 Chapter 4 Installation 6 4 1 DIP Switch Description 6 4 2 Install Secure Door Control Unit 7 Appen...

Страница 7: ...amaged by external force Secure door control unit is the middle layer between access control terminal and door lock in the access control system The top side can be connected to access control termina...

Страница 8: ...dicator The LED indicator only includes the power indicator POWER When the indicator light is solid red it indicates the device is powered on 2 Cable Interface 3 Debugging Port Note The debugging port...

Страница 9: ...Interface Description Figure 2 1 Cable Interface Description Table 2 1 Cable Interface Description Group No Cable No Color Name Description Group A A1 Red 12 V Power Input A2 Black GND Group B B1 Yel...

Страница 10: ...it Button D11 Black GND D12 White Purple DOOR_NC Door Lock Output D13 White Yellow DOOR_COM D14 White Red DOOR_NO 2 2 Wiegand Interface Description Figure 2 2 Wiegand Interface Description Table 2 2 W...

Страница 11: ...Chapter 3 Wiring Description The wiring of external devices is as following Figure 3 1 External Devices Wiring Description DS K2M061 Secure Door Control Unit User Manual 5...

Страница 12: ...ption is as shown in the following figure No 1 to 4 in the figure are switch No Figure 4 1 DIP Switch Description DIP switch meaning is as shown in the following table Table 4 1 DIP Switch Meaning Ico...

Страница 13: ...or other places according to the mounting template Note The minimum bearing weight of the wall or other places should be three times heavier than the device weight 3 Insert the provided plastic sleev...

Страница 14: ...Figure 4 3 Install Secure Door Control Unit DS K2M061 Secure Door Control Unit User Manual 8...

Страница 15: ...Appendix A Dimension Figure A 1 Dimension DS K2M061 Secure Door Control Unit User Manual 9...

Страница 16: ...Hikvision access control and video intercom devices Figure B 1 QR Code of Communication Matrix Device Command Scan the following QR code to get the device common serial port commands Note that the com...

Страница 17: ...UD21173B...

Отзывы: