background image

Secure Door Control Unit                                        www.hikvision.com 

Group 

Cable 

No. 

Color 

Name 

Descriptions 

B1 

Green/Brown 

DOOR_SENSOR 

Sensor Input 

B2 

Black 

GND 

C1 

Green/Black 

DOOR_BUTTON 

Door Button 

C2 

Black 

GND 

D1 

White/Purple 

RELAY_NC 

Lock Output 

D2 

White/Black 

RELAY_COM 

D3 

White/Red 

RELAY_NO 

E1 

Yellow 

RS485 + 

RS-485 

E2 

Black 

GND 

E3 

Blue 

RS485 - 

 

Interface 1

 

Figure 2. 4

 

Rear View of Secure Door Control Unit 

Содержание DS-K2M060

Страница 1: ...1 DS K2M060 Secure Door Control Unit User Manual V1 0 0 UD01462B...

Страница 2: ...company website http overseas hikvision com en Please use this user manual under the guidance of professionals Trademarks Acknowledgement and other Hikvision s trademarks and logos are the properties...

Страница 3: ...gy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause h...

Страница 4: ...the warnings may cause serious injury or death Cautions Neglecting any of the cautions may cause injury or equipment damage Warnings All the electronic operation should be strictly compliance with th...

Страница 5: ...se shall be kept from rain and moisture Exposing the equipment to direct sun light low ventilation or heat source such as heater or radiator is forbidden ignorance can cause fire danger Do not aim the...

Страница 6: ...Introduction 2 1 2 Introducing the Appearance 2 1 2 1 Front View 2 1 2 2 Rear View Dial up 3 1 3 Introducing Indicators 4 Chapter 2 Installation 6 2 1 Introduction of DIP Switch 6 2 2 Wiring Cables 8...

Страница 7: ...2M060 Secure Door Control Unit is the interlayer between the access control terminal and the lock including the door contact the lock the exit button the Wiegand card reader and so on It is much safer...

Страница 8: ...Door Control Unit is shown as below 3 2 1 4 Figure 1 2 Rear View of Secure Door Control Unit Table 1 1 Description of Rear View No Name 1 Cable Interface of RS 485 Power LED Control etc 2 Tampering Pr...

Страница 9: ...485 Communication Indicator Flicking Green The RS 485 communication is built Solid Greed The RS 485 communication is not built RELAY Indicate the lock status Green The indicator will be solid green f...

Страница 10: ...on com 5 BUTTON Indicate the Exit button Green The green light is on when press the Exit button When release the button the green light will be off Notes Make sure the unit is powered on Make sure the...

Страница 11: ...DIP switch module is shown below The number of DIP switch from left to right is 1 to 4 Figure 2 1 DIP Switch Module Binary Code 0000 The table shows below is the description of the DIP switch Table 2...

Страница 12: ...om 7 Figure 2 2 DIP Switch Module Binary Code 0011 The DIP switch in the secure door control unit is for the RS 485 communication The code range is from 1 to 15 namely the binary code range between 00...

Страница 13: ...Chapter 2 1 Introduction of DIP Switch 2 Plug the Terminal 1 to the Interface 1 as shown in Figure 2 3 and Figure 2 4 Group A Group B Group D Group E A1 A2 B1 B2 D1 D2 D3 E1 E2 E3 Power Input Sensor...

Страница 14: ...rown DOOR_SENSOR Sensor Input B2 Black GND C C1 Green Black DOOR_BUTTON Door Button C2 Black GND D D1 White Purple RELAY_NC Lock Output D2 White Black RELAY_COM D3 White Red RELAY_NO E E1 Yellow RS485...

Страница 15: ...he Wiegand interface F1 F2 F3 F4 F5 F6 Wiegand Brown Purple Orange Green White Black Figure 2 5 Terminals 2 The table displayed below shows the terminal 2 descriptions Table 2 3 Terminals Descriptions...

Страница 16: ...Secure Door Control Unit www hikvision com 11 Interface 2 Figure 2 6 Rear View of Secure Door Control Unit...

Страница 17: ...ets of the setscrews in the drilled holes 3 Plug the cables of power input lock input lock output and RS 485 as well as the Wiegand cables to the target interfaces For details please see Chapter 2 2 W...

Страница 18: ...Secure Door Control Unit www hikvision com 13 The hole can be knocked down Figure 2 7 Fix on the Wall...

Страница 19: ...Secure Door Control Unit www hikvision com 14 Chapter 3 Wiring External Device The figure displayed below is the wiring introduction of external device Figure 3 1 External Device Wiring 0100001060602...

Страница 20: ...Secure Door Control Unit www hikvision com...

Отзывы: