background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

       

DS-K2800 Series   

Access Controller 

Quick Start Guide 

 

 

UD.6L0206D1184A01 

 

Содержание DS-K2801

Страница 1: ...DS K2800 Series Access Controller Quick Start Guide UD 6L0206D1184A01...

Страница 2: ...Manual This Manual is applicable to Access Controller Product Name Serials Access Controller DS K2801 Serials Access Controller DS K2802 Serials Access Controller DS K2804 Serials Access Controller T...

Страница 3: ...ONNECTION WITH THE USE OF THIS PRODUCT EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES REGARDING TO THE PRODUCT WITH INTERNET ACCESS THE USE OF PRODUCT SHALL BE WHOLLY AT YOUR OW...

Страница 4: ...t the interference at his own expense FCC Conditions This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interfe...

Страница 5: ...mentation for specific battery information The battery is marked with this symbol which may include lettering to indicate cadmium Cd lead Pb or mercury Hg For proper recycling return the battery to yo...

Страница 6: ...before connecting and disconnecting accessories and peripherals A factory recommended HDD should be used for this device Improper use or replacement of the battery may result in hazard of explosion Re...

Страница 7: ...mpt to disassemble the camera yourself We shall not assume any responsibility for problems caused by unauthorized repair or maintenance Note Please do not drop the objects on hard surface and keep the...

Страница 8: ...READER WIRING 15 4 2 INSTALLING DOOR LOCK 16 4 2 1 Installation of Cathode Lock 16 4 2 2 Installation of Anode Lock 16 4 3 CONNECTING THE EXTERNAL ALARM DEVICE 17 4 4 DOOR BUTTON WIRING DIAGRAM 17 4 5...

Страница 9: ...storage of card number with maximum length of 20 The access controller can store 10 thousand legal cards and 50 thousand card swiping records Supports first card open function super card and super pa...

Страница 10: ...DS K2800 Serial Access Controller 3 Data can be permanently saved after the access controller is powered off Supports I O linkage and event linkage Supports alarm of offline event exceeding 90...

Страница 11: ...ke DS K2804 as an example the component schematic diagram is shown below Figure 2 1 DS K2804 Component Schematic Diagram DS K2800 Component Description Table 2 1 No Component Description DS K2801 DS K...

Страница 12: ...DS K2800 Serial Access Controller 5 No Component Description 4 Jumper Cap for Restoring Factory Settings 5 Working Indicator 6 Alarm Output Indicator 7 Alarm Output NO NC Jumper Cap...

Страница 13: ...DS K2800 Serial Access Controller 6 Chapter 3 Terminal Connection 3 1 DS K2801Terminal Description Figure 3 1 DS K2801 Terminals...

Страница 14: ...Input B5 Wiegand Card Reader 1 OK Indicator of Card Reader Control Output Valid Card Output B6 ERR Indicator of Card Reader Control Output Invalid Card Output B7 BZ Card Reader Buzzer Control Output...

Страница 15: ...W0 Wiegand Head Read Data Input Data0 B17 PWR Card Reader Power Output B18 GND 3 2 DS K2802Terminal Description Figure 3 2 DS K2802 Terminal Description DS K2802 Port Description Table 3 2 No DS K280...

Страница 16: ...Power GND DC12V Grounding D2 12V DC12V Input E1 Alarm Output 2 COM2 Alarm Relay Output 2 Dry Contact E2 NO NC2 E3 Alarm Output 1 COM1 Alarm Relay Output 1 Dry Contact E4 NO NC1 C1 Wiegand Card Reader...

Страница 17: ...t Valid Card Output C16 ERR Indicator of Card Reader Control Output Invalid Card Output C17 BZ Card Reader Buzzer Control Output C18 W1 Wiegand Head Read Data Input Data1 C19 W0 Wiegand Head Read Data...

Страница 18: ...4 Terminal Description Figure 3 3 DS K2804 Access Controller Terminals DS K2804 Port Description Table 3 3 No DS K2804 A1 Alarm Input IN4 Alarm Input 4 A2 GND Grounding A3 IN3 Alarm Input 3 A4 IN2 Ala...

Страница 19: ...SOR Door Magnetic detector A19 Door 2 NC Door Lock Relay Output Dry Contact A20 COM A21 NO A22 BUTTON Door Button Input A23 GND Grounding A24 SENSOR Door Magnetic detector A25 Door 1 NC Door Lock Rela...

Страница 20: ...a0 B13 PWR Card Reader Power Output B14 GND B15 Wiegand Card Reader 3 OK Indicator of Card Reader Control Output Valid Card Output B16 ERR Indicator of Card Reader Control Output Invalid Card Output B...

Страница 21: ...ally open signal is allowed It can be linked to the buzzer of the card reader and access controller and the alarm relay output and open door relat output For single door access controller the Wiegand...

Страница 22: ...er Figure 4 1 Wiring diagram of Wiegand card reader Note You must connect the OK ERR BZ if using access controller to control the LED and buzzer of the Wiegand card reader For 1800 series card reader...

Страница 23: ...00 Serial Access Controller 16 4 2 Installing Door Lock 4 2 1 Installation of Cathode Lock Figure 4 3 Wiring diagram of cathode lock 4 2 2 Installation of Anode Lock Figure 4 4 Wiring diagram of anode...

Страница 24: ...DS K2800 Serial Access Controller 17 4 3 Connecting the External Alarm Device Figure 4 5 External Alarm Device Connection 4 4 Door Button Wiring Diagram Figure 4 6 Power Button Connection...

Страница 25: ...DS K2800 Serial Access Controller 18 4 5 The Connection of Magnetics Detection Figure 4 7 Magnetics Connection 4 6 Connecting Power Supply Figure 4 8 Power Supply Connection...

Страница 26: ...ntroller buzzer buzzes a long warning 3 After the buzzer stops jump the jumper cap back to Normal 4 Disconnect the power and restart the access controller Figure 5 1 Initialization Dial up Note The in...

Страница 27: ...S K2800 Serial Access Controller 20 Figure 5 2 Normally Open Status Lock Relay Normally Closed Status Figure 5 3 Normally Closed Status 5 2 2 Alarm Relay Output Status Alarm Relay Output Normally Open...

Страница 28: ...ure 5 4 Alarm Relay Output Normally Open Alarm Relay Output Normally Closed Figure 5 5 Normally Closed Status Work Flow of Software For detailed information please see the user manual of the client so...

Страница 29: ...DS K2800 Serial Access Controller 22 Figure 5 6 Software Client Work Flow...

Страница 30: ...rted 6 1 Activation via SADP Software SADP software is used for detecting the online device activating the device and resetting the password Get the SADP software from the supplied disk or the officia...

Страница 31: ...ase letters lower case letters numbers and special characters in order to increase the security of your product And we recommend you reset your password regularly especially in the high security syste...

Страница 32: ...Save button to activate your IP address modification 6 2 Activation via Client Software The client software is versatile video management software for multiple kinds of devices Get the client software...

Страница 33: ...hown in the figure below 2 Click the icon on the upper left side of the page select Access Control to enter the control panel 3 Click the Controller Management icon to enter the Controller Management...

Страница 34: ...27 4 Check the device status from the device list and select an inactive device 5 Click the Activate button to pop up the Activation interface 6 Create a password and input the password in the passwo...

Страница 35: ...ct And we recommend you reset your password regularly especially in the high security system resetting the password monthly or weekly can better protect your product 7 Click OK button to start activat...

Страница 36: ...DS K2800 Serial Access Controller 1...

Отзывы: