FCC Information
Please take attention that changes or modification not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment. FCC
compliance: This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
—Consult the dealer or an experienced radio/TV technician for help.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operation.
2006/66/EC (battery directive): This product contains a battery that cannot
be disposed of as unsorted municipal waste in the European Union. See the
product documentation for specific battery information. The battery is
marked with this symbol, which may include lettering to indicate cadmium
(Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to
your supplier or to a designated collection point. For more information see:
www.recyclethis.info
2012/19/EU (WEEE directive): Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the European Union. For proper
recycling, return this product to your local supplier upon the purchase of
equivalent new equipment, or dispose of it at designated collection points.
For more information see: www.recyclethis.info
This product and - if applicable - the supplied accessories too are marked
with "CE" and comply therefore with the applicable harmonized European
standards listed under the RE Directive 2014/53/EU, the EMC Directive
2014/30/EU, the RoHS Directive 2011/65/EU.
Warning
In the use of the product, you must be in strict compliance with the electrical safety
regulations
of the nation and region.
CAUTION: To reduce the risk of fire, replace only with the same type and rating of fuse.
CAUTION: This equipment is for use only with Hikvision’s bracket. Use with other (carts,
stands, or carriers) may result in instability causing injury.
To prevent possible hearing damage, do not listen at high volume levels for long periods.
Please use the power adapter, which is provided by normal company. The power
consumption cannot be less than the required value.
Do not connect several devices to one power adapter as adapter overload may cause over-
heat or fire hazard.
Please make sure that the power has been disconnected before you wire, install or
dismantle the device.
When the product is installed on wall or ceiling, the device shall be firmly fixed.
If smoke, odors or noise rise from the device, turn off the power at once and unplug the
power cable, and then please contact the service center.
If the product does not work properly, please contact your dealer or the nearest service
center. Never attempt to disassemble the device yourself. (We shall not assume any
responsibility for problems caused by unauthorized repair or maintenance.)
Caution
identifies the positive terminal(s) of equipment which is used with, or generates
direct current. + identifies the negative terminal(s) of equipment which is used with,
or generates direct current.
No naked flame sources, such as lighted candles, should be placed on the equipment.
The USB port of the equipment is used for connecting to a USB flash drive only. The
serial port of the equipment is used for debugging only.
Burned fingers when handling the fingerprint sensor metal. Wait one-half hour atier
switching off before handling the parts.
Install the equipment according to the instructions in this manual.
To prevent injury, this equipment must be securely attached to the floor/wall in
accordance with the installation instruations.
Do not drop the device or subject it to physical shock, and do not expose it to high
electromagnetism radiation. Avoid the equipment installation on vibrations surface or
places subject to shock (ignorance can cause equipment damage).
Do not place the device in extremely hot (refer to the specification of the device for
the detailed operating temperature), cold, dusty or damp locations, and do not expose it
to high electromagnetic radiation.
The device cover for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low ventilation or heat source such as
heater or radiator is forbidden (ignorance can cause fire danger).
Do not aim the device at the sun or extra bright places. A blooming or smear may
occur otherwise (which is not a malfunction however), and affecting the endurance of
sensor at the same time.
Please use the provided glove when open up the device cover, avoid direct contact
with the device cover, because the acidic sweat of the fingers may erode the surface
coating of the device cover.
Please use a soti and dry cloth when clean inside and outside surfaces of the device
cover, do not use alkaline detergents.
Please keep all wrappers atier unpack them for future use. In case of any failure
occurred, you need to return the device to the factory with the original wrapper.
Transportation without the original wrapper may result in damage on the device and
lead to additional costs.
Improper use or replacement of the battery may result in hazard of explosion.
Replace with the same or equivalent type only.
Dispose of used batteries according to the instructions provided by the battery
manufacturer.
Biometric recognition products are not 100% applicable to anti-spoofing environments.
If you require a higher security level, use multiple authentication modes.
Please make sure that the biometric recognition accuracy will be affected by the
collected pictures' quality and the light in the environment, which cannot be 100%
correct.
Secure Door Control Unit
NC
COM
NO
C1
C2
C3
Face Recognition Terminal
Secure Door
Control Unit
Wiring Terminal
Power Input
Sensor Input
Exit Button
Lock Output
SENSOR
BUTTON
Black GND
Green/Brown
Green/Black
Black
Black
White/Purple
White/Black
White/Red
Red
B1
B2
B 3
B4
(NC)
Power
(NO)
Door Contact
Exit Button
Electric
Dropbolt
Electric
Strike
Black
Yellow
Blue
GND
GND
GND
+12 V
A1
A2
+12 V
C1
C2
C3
485+
485-
GND
RS-485
3.2 Device Wiring (With Secure Door Control Unit)
3.1 Wiring (Normal)
RS-485
Power Input
GND
Black
Green
White
GND
Group C
Group A
12 VDC
Red
Black
Black
Yellow
Blue
White/Yellow
White/Purple (NC)
(COM)
D1
D2
Door Contact
Power Supply
SEN
NC
COM
NO
GND
BTN
Group D
Black
Yellow/Gray
White/Red
Yellow/Green
NO
COM
NC
COM
NO
NC
(NO)
D3
D4
D5
D6
Group B
IN2
GND
IN1
Yellow/Orange
Black
Yellow/Blue
Yellow/Red
Yellow/Brown
Yellow/Purple
NO
COM
NC
B1
B2
B3
B4
B5
B6
C1
C2
C3
C4
C5
C6
Alarm Output
Wiegand
Door Lock
Electric Dropbolt
Electric Strike
Exit Button
GND
W0
W1
A1
A2
Network Interface
Alarm Input
485+
485-
When connec�ng door contact and exit bu�on,
the device and the RS-485 card reader should
use the same common ground connec�on.
The Wiegand terminal here is a Wiegand output
terminal. You should set the device’s Wiegand
direc�on to “output”.
The suggested external power supply for door
lock is 12 V, 1 A
.
The suggested external power supply for
Wiegand card reader is 12 V, 1 A
.
Do not wire the device to the electric supply
directly.
For scenarios with high safety requirement, use the secure door
control unit wiring first. You can ask the technical support to purchase
for the secure door control unit separately.
The secure door control unit should connect to an external power
supply separately. The suggested external power supply is 12 V, 0.5 A.
The picture here are parts of the wiring. For details, see the secure
door control unit's user manual.
Select one of the following steps to activate the device.
1. Activate via Web.
2. Activate via iVMS-4200 client.
Activate Device
4 Quick Operation
Characters containing admin and nimda are
not supported to be set as activation password.
For details, please refer to the user manual.
STRONG PASSWORD RECOMMENDED–
We highly recommend you create a strong password of your own
choosing (using a minimum of 8 characters, including upper case
letters, lower case letters, numbers, and special characters) in
order to increase the security of your product. And we
recommend you reset your password regularly, especially in the
high security system, resetting the password monthly or weekly
can better protect your product.