Title:
How to Connect Card Reader to Door
Station
Version:
v1.0
Date:
5/19/2017
Product:
Video Intercom Device
Page:
2 of 5
Description of DIP Switch:
Icon
Description
Represent 1 in binary mode
Represent 0 in binary mode
No.
Description
DIP Switch Status
1~4
Address of RS485
1: 1
0: 0
5
Read card No. or file in card(Reserved)
1: read card No;
0: read file in card.
6
Wiegand protocol or RS-485 protocol
1: Wiegand protocol
0: RS-485 protocol.
7
Wiegand Protocol
(available when No. 6 is 1)
1: Wiegand protocol of 26-bit;
0: Wiegand protocol of 34-bit.
8
Wiegand Protocol
(available when No. 6 is 1)
1: Enable;
0: Disable.
Mothed 1: RS485 Wiring
Step 1:
Please set the DIP switch firstly before connecting the card reader, the binary value of the card reader
is1000 0000, please set as the following picture;
Step 2:
Please connect card reader to door station as following picture: