background image

 

Title: 

How to Connect Card Reader to Door 
Station 

Version:

 

v1.0 

Date:

 

5/19/2017 

Product: 

Video Intercom Device 

Page: 

2 of 5 

 

Description of DIP Switch: 

 

Icon 

Description 

 

 

Represent 1 in binary mode 

 

 

Represent 0 in binary mode 

 

No. 

Description 

DIP Switch Status 

1~4 

Address of RS485 

1: 1 
0: 0 

Read card No. or file in card(Reserved) 

1: read card No; 

0: read file in card. 

Wiegand protocol or RS-485 protocol 

1: Wiegand protocol 

0: RS-485 protocol. 

Wiegand Protocol 

(available when No. 6 is 1) 

1: Wiegand protocol of 26-bit; 
0: Wiegand protocol of 34-bit. 

Wiegand Protocol 

(available when No. 6 is 1) 

1: Enable; 

0: Disable. 

 

Mothed 1: RS485 Wiring

 

Step 1:  

Please set the DIP switch firstly before connecting the card reader, the binary value of the card reader 

is1000 0000,  please set as the following picture; 

 

 
 

Step 2:  

Please connect card reader to door station as following picture: 

 

 

Отзывы: