HIKVISION DS-3E1106HP-EI Скачать руководство пользователя страница 7

• CAUTION: Risk of explosion if the battery is replaced by an incorrect type.

• Improper replacement of the battery with an incorrect type may defeat a safeguard (for

example, in the case of some lithium battery types).

• Do not dispose of the battery into fire or a hot oven, or mechanically crush or cut the battery,

which may result in an explosion.

• Do not leave the battery in an extremely high temperature surrounding environment, which may

result in an explosion or the leakage of flammable liquid or gas.

• Do not subject the battery to extremely low air pressure, which may result in an explosion or the

leakage of flammable liquid or gas. Dispose of used batteries according to the instructions.

Caution

• CAUTION: Double pole/Neutral fusing. After operation of the fuse, parts of the device that

remain energized might represent a hazard during servicing.

• The device has been designed, when required, modified for connection to an IT power

distribution system.

• This device is suitable for mounting on concrete or other non-combustible surface only.

• The ventilation should not be impeded by covering the ventilation openings with items, such as

newspapers, table-cloths, curtains, etc. The openings shall never be blocked by placing the

device on a bed, sofa, rug or other similar surface.

• No naked flame sources, such as lighted candles, should be placed on the device.

• The device shall not be exposed to dripping or splashing and that no objects filled with liquids,

such as vases, shall be placed on the device.

• Burned fingers when handling the cover area of the device. Wait one-half hour after switching

off before handling the parts.

• CLASS 1 LASER PRODUCT

100 Mbps Hi-PoE Switch Quick Start Guide

vi

Содержание DS-3E1106HP-EI

Страница 1: ...100 Mbps Hi PoE Switch Quick Start Guide...

Страница 2: ...ILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL CONSEQUENTIAL INCIDENTAL OR INDIRECT DAMAGES INCLUDING AMONG OTHERS DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION OR LOSS OF DATA CORRUPTION...

Страница 3: ...TIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL CYCLE OR IN SUPPORT OF HUMAN RIGHTS ABUSES IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW THE LATE...

Страница 4: ...wo conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation EU Conformity Statement Thi...

Страница 5: ...ollection point For more information see http www recyclethis info Industry Canada ICES 003 Compliance This device meets the CAN ICES 3 A NMB 3 A standards requirements 100 Mbps Hi PoE Switch Quick St...

Страница 6: ...s powered via the PoE port have their shells protected and fire proofed because the switches are not compliant with the Limited Power Source LPS standard In the use of the product you must be in stric...

Страница 7: ...peration of the fuse parts of the device that remain energized might represent a hazard during servicing The device has been designed when required modified for connection to an IT power distribution...

Страница 8: ...t port management and so on The switches are suitable for small scale LAN device access 1 2 Packing List Please check if there is any damage of the package first According to the packing list make sur...

Страница 9: ...tor Solid The switch is powered on normally Unlit No power supply connected or power supply is abnormal LINK ACT Indicator Solid The port is connected Flashing The port is transmitting data Unlit The...

Страница 10: ...re all the configurations of the switch to the default settings Grounding Terminal Used for connecting to the grounding cable to protect the switch from lightning Power Supply Use the attached power a...

Страница 11: ...device on the desk 2 2 Wall Mounted Installation Before You Start Prepare the tools Steps 1 Check the distance between the two hanging holes on the rear cover of the device 2 Insert two M4 screws into...

Страница 12: ...grounding bar 2 Connect the other end of the grounding cable to the grounding terminal of the device and fix the screw Figure 3 1 Ground with Grounding Bar 3 1 2 Without Grounding Bar If there is no...

Страница 13: ...Angle Steel 3 2 Connect RJ45 Port Use a network cable to connect the device to the RJ45 port of a peer device such as network camera NVR switch etc Figure 3 3 RJ45 Port Connection 100 Mbps Hi PoE Swit...

Страница 14: ...r supply is compliant with rated input standard Port cables and grounding cables are correctly connected If there is outdoor cabling connect a lightning rod and lightening arrester to the cable Cautio...

Страница 15: ...sword to activate them before they can be added to the software and work properly Before You Start Make sure the device to be activated is connected to the network and is in the same network segment w...

Страница 16: ...he client also supports importing multiple devices in a batch when there are large amount of devices to be added The section only introduces one mode namely adding a detected online device Steps 1 Ent...

Страница 17: ...and special characters in order to increase the security of your product And we recommend you change your password regularly especially in the high security system changing the password monthly or we...

Страница 18: ...Chapter 6 Get More Information Scan the QR code below for iVMS 4200 software operations 100 Mbps Hi PoE Switch Quick Start Guide 11...

Страница 19: ...UD22877B...

Отзывы: