User Manual of Digital Video Recorder
145
exception message to the host when an alarm is triggered. The remote alarm host must have the
CMS (Client Management System) software installed.
The
Alarm Host IP
refers to the IP address of the remote PC on which the CMS (Client
Management System) software (e.g., iVMS-4200) is installed, and the
Alarm Host Port
must be the
same as the alarm monitoring port configured in the software (default port is 7200).
Multicast IP
: The multicast can be configured to realize live view for more than the maximum
number of cameras through network. A multicast address spans the Class-D IP range of 224.0.0.0 to
239.255.255.255. It is recommended to use the IP address ranging from 239.252.0.0 to
239.255.255.255.
When adding a device to the CMS (Client Management System) software, the multicast address
must be the same as the device’s multicast IP.
RTSP Port
: The RTSP (Real Time Streaming Protocol) is a network control protocol designed for
use in entertainment and communications systems to control streaming media servers.
Enter the RTSP port in the text field of
RTSP Port
. The default RTSP port is 554, and you can
change it according to different requirements.
Server Port
and
HTTP Port
: Enter the
Server Port
and
HTTP Port
in the text fields. The default
Server Port is 8000 and the HTTP Port is 80, and you can change them according to different
requirements.
The Server Port should be set to the range of 2000-65535 and it is used for remote client software
access. The HTTP port is used for remote IE access.
Figure 9. 21
Configure More Settings
4.
Click the
Apply
button to save and exit the interface.
9.2.7
Configuring HTTPS Port
Purpose:
HTTPS provides authentication of the web site and associated web server that one is communicating with,
which protects against Man-in-the-middle attacks. Perform the following steps to set the port number of https.
Example:
If you set the port number as 443 and the IP address is 192.0.0.64, you may access the device by inputting
https://192.0.0.64:443
via the web browser.
The HTTPS port can be only configured through the web browser.
Steps:
1.
Open web browser, input the IP address of device, and the web server will select the language
automatically according to the system language and maximize the web browser.
Содержание 7200HQHI-SH Series
Страница 1: ...Digital Video Recorder User Manual UD 6L0202D1703A02...
Страница 14: ...User Manual of Digital Video Recorder 14 Chapter 1 Introduction...
Страница 30: ...User Manual of Digital Video Recorder 30 Chapter 2 Getting Started...
Страница 42: ...User Manual of Digital Video Recorder 42 Chapter 3 Live View...
Страница 54: ...User Manual of Digital Video Recorder 54 Chapter 4 PTZ Controls...
Страница 65: ...User Manual of Digital Video Recorder 65 Chapter 5 Recording Settings...
Страница 86: ...User Manual of Digital Video Recorder 86 Chapter 6 Playback...
Страница 102: ...User Manual of Digital Video Recorder 102 Chapter 7 Backup...
Страница 114: ...User Manual of Digital Video Recorder 114 Chapter 8 Alarm Settings...
Страница 119: ...User Manual of Digital Video Recorder 119 Figure 8 9 Copy Settings of Alarm Input...
Страница 134: ...User Manual of Digital Video Recorder 134 Chapter 9 Network Settings...
Страница 155: ...User Manual of Digital Video Recorder 155 Chapter 10 HDD Management...
Страница 169: ...User Manual of Digital Video Recorder 169 Chapter 11 Camera Settings...
Страница 173: ...User Manual of Digital Video Recorder 173 Chapter 12 DVR Management and Maintenance...
Страница 181: ...User Manual of Digital Video Recorder 181 Chapter 13 Others...
Страница 190: ...User Manual of Digital Video Recorder 190 Appendix...