2. Charger
Symptom
Possible cause
Remedy
The charge indicator
lamp is rapidly
fl
ickers
purple, and battery
charging doesn’t begin.
The battery is not inserted all the
way.
Insert the battery
fi
rmly.
There is foreign matter in the
battery terminal or where the
battery is attached.
Remove the foreign matter.
The charge indicator
lamp blinks red, and
battery charging
doesn’t begin.
The battery is not inserted all the
way.
Insert the battery
fi
rmly.
The battery is overheated.
If left alone, the battery will
automatically begin charging if
its temperature decreases, but
this may reduce battery life. It is
recommended that the battery be
cooled in a well-ventilated location
away from direct sunlight before
charging it.
Battery usage time is
short even though the
battery is fully charged.
The battery’s life is depleted.
Replace the battery with a new
one.
The battery takes a
long time to charge.
The temperature of the battery,
the charger, or the surrounding
environment is extremely low.
Charge the battery indoors or in
another warmer environment.
The charger’s vents are blocked,
causing its internal components to
overheat.
Avoid blocking the vents.
The cooling fan is not running.
Contact a HiKOKI Authorized
Service Center for repairs.
Charging of a USB
device pauses midway.
The charger was plugged into an
electrical socket while the USB
device was being charged using
the battery as the power source.
This is not a malfunction.
The charger pauses USB
charging for about 5 seconds
when it is di
ff
erentiating between
power sources.
A battery was inserted into the
charger while the USB device
was being charged using a power
socket as the power source.