5
.
Adjustments
調節裝置
38
(7) Reset the adjusting screw
○
2
when the needle is at the lowest point and the presser foot touches
closely on the stitch plate. Then tighten the screw
○
3
of the presser bar connecting bracket while
pushing slightly down.
(8) Reset the seal plug
○
1
.
(9) Reset all needles.
注意:
在調整機器之前,一定要先把電源關掉,並確定馬達完全停止。
WARNING
Before adjusting, always turn the motor stitch OFF and check that the motor has already stopped.
5.11
置換壓腳彈簧片
5.11
Replacing presser foot spring plate
5.11.1
拆除方法
(1)
拆掉螺絲
○
1
。
(2)
拆掉壓腳彈片
○
2
。
(3)
移開彈簧片勾
○
3
才能拿掉彈簧片
○
2
。
5.11.1
Removing:
(1) Remove the screw
○
1
.
(2) Remove the presser foot sprint plates
○
2
from the presser foot. Fig.69
(3) Remove each plate
○
2
from the spring plate
holder
○
3
.
5.11.2
組裝方法
(1)
重新裝上壓腳彈片
○
2
和壓腳彈片勾
○
3
。
(2)
每片彈簧片
○
2
要對齊壓腳座。
(3)
鎖上螺絲
○
1
。