12
P-137
Setting the number of
Mid-back latch
stitching
1~10 times
1~10 1
1
P-138
Lock screen function
setting
0
:
invaild 1
:
vaild
0~1 1
1
P-139
Lock screen time
setting
30~240 (s)
0~1 30
1
P-140
Anti-bird's nest delay
before hooking
The delay time between the end of trimming and
the hook
0
~
500ms
30 2
P-141
Anti-bird's nest
Hook time
Wire hooking solenoid time
0
~
500ms
80 2
P-142
Anti-bird's nest
delay after hooking
The delay time of hooking solenoid off
0
~
500ms
50 2
P-143
Anti-bird's nest
Hook line duty cycle
Adjust the strength of the hooking solenoid
0
~
100
100 2
P-144
Anti-bird's nest
Suction action time
Working time of suction valve
0
~
2000ms
350 2
P-145
Thread-straight work
time of Anti-nest
The work time of a thread-straight solenoid
0
~
500ms
50 2
P-146
Anti-bird's nest
Suction start angle
start angle during thread trimming
150
~
360
154 2
P-150
Maximum needle
gauge setting
needle gauge of 5mm stitch length
(1.0mm~5.0mm)
needle gauge of 7mm stitch length model
(1.0mm~7.0mm)
10
~
50
(
70
)
mm
50 2
P-151
First off-line
prevented stitch
length
0
:
invaild 1
:
vaild
0~1 0
2
P-152
First off-line
prevented stitch
length setting
Stitch length setting
Parameter range (1.0mm~5.0mm
)
10
~
50
40 2
P-153
Head button inching
mode setting
0
:
Invalid 1
:
valid
(
Press once valid ,press again
cancel, such as close sewing, over thickness,
presser foot
)
0~1 0
2
P-154
Back stitch button
type
0: Ordinary switch 1: Travel switch
0~1 0
3
P-155
LED light setting
0
:
LED light light off
1~5
:
Adjust the brightness
(
HMI control
0/1/2/3/4/5/0switch
)
0~5 5
2
P-156
Refueling reminder
time setting
0: invalid
15~3000: Power-on trial time
0~3000 0 3
P-161
1/2 Fill needle button
setting
0
:
Back latch sewing 1
:
tight sewing 2
:
1/2 fill
needle
0~2 2
2
P-170
Speed adjust
coefficient
=0, P171~P176 are invalid
=1, P171~P176 are valid
0~1 1
2
P-171
Speed forward
sewing adjust
Speed forward sewing adjust
50~150 100 2