HIK VISION DS-K2601 Скачать руководство пользователя страница 1

 

Title: 

DS-K4H250/450/258 series magnetic lock 
connect to DS-K2600 series Access Controller 

Version: 

v1.0 

Date: 

01/11/2018 

Product: 

Access Control Device 

Page: 

1 of 9 

 

 

DS-K

4H250/450/258 series magnetic lock connect to DS-

K2600 series Access Controller 

 

Preparation

 

Connecting magnetic lock to access controller is mainly applied to swiping card to open the door for 

exiting. For magnetic lock and access controller in this document, please check the table below: 

 

Magnetic Lock 

Access Controller 

DS-K4H250S 

DS-K4H250D 
DS-K4H450D 

DS-K2601 
DS-K2602 
DS-K2604 

DS-K4H258S 

DS-K4H258D 

 

Note

 

This document is simply used to guide users how to wire correctly and ensure access controllers can 

control locks.  

The access controller model in this document is DS-K2604. 

Part 1 is mainly for magnetic lock wiring, and Part 2 and Part 3 are mainly for the situation that users 

could get the door status on iVMS-4200 Client. 

 

 

Notice

 

1.

 

Please cut off power supply before wiring; 

2.

 

Please use a tool to screw magnetic lock screws in following picture, and remove the cover of 

magnetic lock, find V+/V- and NO/NC & COM interfaces of magnetic lock in following picture;  

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание DS-K2601

Страница 1: ...Lock Access Controller DS K4H250S DS K4H250D DS K4H450D DS K2601 DS K2602 DS K2604 DS K4H258S DS K4H258D Note This document is simply used to guide users how to wire correctly and ensure access controllers can control locks The access controller model in this document is DS K2604 Part 1 is mainly for magnetic lock wiring and Part 2 and Part 3 are mainly for the situation that users could get the d...

Страница 2: ...ondingly there are lock and door magnetic interfaces in DS K2600 series access controllers as pictures show Note means lock interface means door magnetic interface Access Controller Interface DS K2601 DS K2602 DS K2604 Interface Description Note V V Power Supply NO NC COM Door Magnetic Singnal Output DS K4H258S D series magnetic locks don t have NO NC and COM interfaces ...

Страница 3: ...ccess Control Device Page 3 of 9 Part 1 Lock Lock Wiring DS K4H250S DS K4H258S Please connect as the following picture Magnetic lock LED status Normal Close Door Normal Open Door Abnormal DS K4H250D DS K4H450D DS K4H258D Please connect as the following picture Magnetic lock LED status Normal Close Door Normal Open Door Abnormal ...

Страница 4: ...Product Access Control Device Page 4 of 9 Part 2 Lock Lock NC COM Wiring Step 1 DS K4H250S Please connect as the following picture Magnetic lock LED status Normal Close Door Normal Open Door Abnormal DS K4H250D DS K4H450D Please connect as the following picture COM V V NO NC NC V COM V NO Lock1 Lock1 Door Magnetic1 GND ...

Страница 5: ...rmal Open Door Abnormal Step 2 Add access controller to iVMS 4200 Client Step 3 Click Tool Device Arming Control check your access controller arming status The icon means device was armed by iVMS 4200 Client Step 4 Enter Access Control Advanced Function Access Control Parameters interface set Door Magnetic Sensor as Remian Closed and it should be consistent with the wiring of Door Magnetic Singnal...

Страница 6: ...age 6 of 9 Step 5 Enter Status Monitor Door Status interface open the door check door status on iVMS 4200 Client and the magnetic lock LED status Magnetic Lock LED status Door Status Alarm Event Part 3 Lock Lock NO COM Wiring Step 1 DS K4H250S Please connect as the following picture Magnetic lock LED status Normal Close Door Normal Open Door Abnormal ...

Страница 7: ...H250D DS K4H450D Please connect as the following picture Magnetic lock LED status Normal Close Door Normal Open Door Abnormal Step 2 Add access controller to iVMS 4200 Client Step 3 Click Tool Device Arming Control check your access controller arming status The icon means device was armed by iVMS 4200 Client Lock1 Lock1 Door Magnetic1 GND COM V V NO NC NC V COM V NO ...

Страница 8: ... should be consistent with the wiring of Door Magnetic Singnal Output Step 5 Enter Status Monitor Door Status interface open the door check door status on iVMS 4200 Client and the magnetic lock LED status Magnetic Lock LED status Door Status Alarm Event NOTE Abnomal in Magnetic lock LED status part could be displaied in following scenario open door timeout abnomally open door by force as well as n...

Страница 9: ...50 450 258 series magnetic lock connect to DS K2600 series Access Controller Version v1 0 Date 01 11 2018 Product Access Control Device Page 9 of 9 First Choice for Security Professionals HIKVISION Technical Support ...

Отзывы: