d.

 

Unlock the failed drive’s disk module of the storage enclosure and remove the failed drive by gently 
sliding the drive module out of the enclosure.

 

WARNING

: Make absolutely sure that you remove the failed drive indicated by the GUI. Reinstall the disk 

module immediately if you remove the wrong disk module.

 

e.

 

Replace the failed drive with a new disk module and secure in place. Once the drive has spin up to speed, 
the WebGUI will indicate that the array is rebuilding (The “Status” shows Rebuilding and the percentage 
complete) as shown below. The rebuild time is approximately 2 hours per TB. 

 

 

f.

 

Once the rebuild is complete, the RAID array will return to the Normal status. Your data is now secure. 
 

10.

 

Expanding RAID Storage Capacity 

The RocketStor 6328 Adapter supports 

OCE/ORLM 

(

O

nline 

C

apacity 

E

xpansion / 

O

nline 

R

AID 

L

evel 

M

igration). 

OCE/ORLM can expand current RAID storage configurations when capacity is running short, or migrate a RAID 
array to a different RAID level, without deleting existing data. 

 

Warning

: The OCE/ORLM process is irreversible. Please make sure each disk is in good health before 

proceeding.  

 
To use OCE/ORLM: 

Step 1:  Install the new disks and/or storage enclosure and attach it to the RocketStor 6328 using the 

appropriate eSATA or Mini-SAS cable (see page 6 for more information). 

Step 2:  Boot Windows and start the WebGUI. 

Step 3:  Under the 

Logical

 tab, click 

Maintenance

 to the right of the 

Status

 column of the target array to 

initiate the OCE/ORLM procedure.  

a.

 

From the drop down-menu, select the desired RAID level. 

 

 

b.

 

Click the OCE/ORLM button to open the 

Array Transform/transforming

 window. 

Содержание RocketStor 6328

Страница 1: ...HighPoint Technologies Inc 1 RocketStor 6328 Thunderbolt 2 RAID Host Adapters User s Guide Revision 1 00 Mar 21 2014 HighPoint Technologies Inc...

Страница 2: ...PENDIX A Using the WebGUI full guide 18 1 Running the HighPoint Web RAID Management software WebGUI 18 2 Web RAID Management Software Global View 19 3 Web RAID Management Software Physical 20 3 1 Phys...

Страница 3: ...Mac or Windows PC platform with Thunderbolt capability Key features Dual 20Gb s Thunderbolt Ports 8x 6Gb s SAS SATA ports Hardware RAID 0 1 5 6 10 50 and JBOD 2 System Requirement A Apple Mac or PC Sy...

Страница 4: ...rts Data Transfer Rate 20Gbps Bi directional Device Ports Dual External Mini SAS ports SFF 8088 Devices Interface Mini SAS eSATA Port Multiplier cable sold separately RAID Levels Integrated Hardware R...

Страница 5: ...s Mute button or the Rescan function found under the Physical or Logical tabs b Check the physical device status if there are any disabled drives c Locate the disk module number d If the RAID is in cr...

Страница 6: ...connection diagram 6 2 Connecting the RocketStor 6328 RS6328 Steps a Connect the RS6328 to the storage enclosure using an industry standard Mini SAS cable Power on the storage enclosure b Connect the...

Страница 7: ...ke sure the host system s Thunderbolt driver has been installed c Open the Windows Device Manager The RS6328 will be recognized as a RAID controller under Other devices d Insert the HighPoint software...

Страница 8: ...install the Web RAID Management software also known as the WebGUI a WebGUI Installation Windows Insert the HighPoint software CD into a CD DVD drive The program should start automatically Click the S...

Страница 9: ...ys 7 1 Configuring RAID Arrays The RS6328 supports multiple RAID levels The steps below describe how to quickly configure a RAID5 array with 8 bay 8 disk storage enclosures Step 1 Verify the physical...

Страница 10: ...r of disks For more detailed instructions see section 4 1 Logical Create Array on page 20 Note We recommend using identical hard disk when creating a RAID array In addition only use enterprise class R...

Страница 11: ...HighPoint Technologies Inc 11 e Click the Create button to create the array f The following diagram displays RAID5 foreground initialization in progress...

Страница 12: ...ray attached to the RS6328 will be recognized automatically A newly created RAID Array or a new disk will be recognized as an empty disk It must be initialized before it can be used Initializing new s...

Страница 13: ...connected to the host system using the Thunderbolt cable shutting down the host will automatically power down the RS6328 8 Deleting RAID Storage To delete a RAID array a Log in to the WebGUI b Switch...

Страница 14: ...the array is now in an unprotected state and the failed drive should be replaced as soon as possible to avoid data loss NOTE If the storage was configured in RS6328 RAID 6 mode up to two drives can f...

Страница 15: ...secure 10 Expanding RAID Storage Capacity The RocketStor 6328 Adapter supports OCE ORLM Online Capacity Expansion Online RAID Level Migration OCE ORLM can expand current RAID storage configurations wh...

Страница 16: ...t be equal or larger than the source RAID array e Click Create button to begin the OCE ORLM process Step 4 Once the OCE ORLM procedure is complete Disk Management will recognize the new storage capaci...

Страница 17: ...authorized service or parts Warranty service is available to the purchaser by obtaining a Return Material Authorization number RMA and by delivering the Product during the warranty period to an author...

Страница 18: ...oading and installing the WebGUI open the WebGUI by double clicking the icon found on the desktop Login to the WebGUI and configure the RAID arrays Use the default user name RAID and password hpt to l...

Страница 19: ...t should be always 0 D Physical Drive Total physical drives detected by this RAID controller E Legacy Disk Total physical drives which has partition information created detected by this RAID controlle...

Страница 20: ...troller BIOS version Vendor Vendor Name PCI Bus Number PCI slot information PCI Device Number PCI device number PCI Func Number PCI function number B Extended Information It lists other controller inf...

Страница 21: ...n number of the device on the RAID controller Max Free Max free space for creating a single disk JBOD or to be part of a RAID array Status Device status is Legacy or Normal Serial Number Serial Number...

Страница 22: ...gical Device Information It is the logical disk that is connected to the RAID controller and has already been reported to the operating system Example Check the Windows Disk Management utility B Physi...

Страница 23: ...need to provide information to the Web GUI utility which in turn instructs the RocketStor 6328 how to configure the array The following diagram illustrates the Create Array page A Array Type Choose t...

Страница 24: ...necessary for new drives as they contain no data c In some cases this option can be used to recover disabled RAID arrays 2 Quick Init The RAID array will be immediately accessible a This option will d...

Страница 25: ...es superior data protection when there is a power failure Data is written directly to disk E Block Size Block sizes are adjustable from 16K through 1024K default is 64K F Number of RAID5 member disks...

Страница 26: ...of the RAID array Cache Policy Redundant RAID array options for performance or protection Block Size RAID array block size Sector Size RAID array sector size OS Name Name of HDD seen in the OS Status...

Страница 27: ...ower off the RAID array and remove it Without using this feature removing any disk member will trigger the alarm 3 Verify This option is only available when RAID is in Normal status 4 Add This option...

Страница 28: ...lost due to power failure or some other circumstance Write Back Higher write performance but chances of data lose are greater since data still resides in cache 7 Rename Rename the array 4 2 Logical Sp...

Страница 29: ...evices hosted by the RAID controller 4 4 Logical Rescan When hot plugging a single device or RAID array the Rescan button prompts the RAID controller to scan for device changes 4 5 Logical Beeper Mute...

Страница 30: ...to continue Warning this option should only be enabled in the case of an emergency data inconsistency or data loss may result Review the Event Log before enabling this option and check for HDD bad se...

Страница 31: ...nd other system tasks High High Priority the majority of available system resources will be directed towards the rebuild procedure Highest Highest Priority the RAID controller will utilize all availab...

Страница 32: ...C Mail From This is email address of the sender D Login Name The login name of send s email account E Password The login password of send s email account F SMTP Port This is SMTP port number The defa...

Страница 33: ...ctivity including administrative actions warnings and hardware failures There are three options to operate this event log section Clear Click Clear to remove all current entries from the Event View lo...

Страница 34: ...ed the HDD s can be placed onto the onboard SATA SAS port and a 3rd party SMART software utility can be run HDD Temperature Threshold Setup the HDD temperature threshold to prevent HDD overheating Whe...

Страница 35: ...nce sessions for RAID 1 5 6 10 and 50 arrays User can name each task and specify the frequency date hour minute and second for each session Regular maintenance is highly recommended for any redundant...

Страница 36: ...gned the disabled status This feature helps protect RAID configurations by storing multiple copies of RAID configuration data which administrators can use to restore a disabled RAID array Note Please...

Страница 37: ...urs when the data verification fails or when adding a new disk into the Critical array The array status is Critical This indicates that current array needs rebuild This icon will also show up on a dev...

Страница 38: ...ritical Array disk member diagram is listed below The array is rebuilding and its current status is Rebuilding Array disk member diagram is listed below The array is not available Two scenarios can ca...

Страница 39: ...ve failures Useable storage capacity equals total capacity of all drives in the array minus two Fast database and application servers which need performance and data protection RAID 5 Disk Striping wi...

Страница 40: ...in feature can connect the host system with 6 Thunderbolt devices or 5 devices and 1 display Configuration 1 Connect the host with 6 Thunderbolt Devices Configuration 2 Connect the host with 5 Thunder...

Отзывы: