We recommend proper grounding by using a grounding strap. Make sure to work in 
a clean and static-free area, and avoid wearing clothing that retains static charges. 

Part 3 - Hardware Installation and Verification  

Before installing the RocketRAID mini-SAS 6G series controller  

 

Make sure computer is turned off and unplugged from its power source  

 

Take appropriate electrostatic discharge precautions:. 

Remove the PCIe slot cover. 

Gently insert the RocketRAID mini-SAS 6G series controller into the PCIe slot and 
secure the bracket to the computer chassis according to your chassis specifications. 

After installing the RocketRAID mini-SAS 6G series controller, restart your computer. 

After your computer has started, insert the Driver & Software Installation Disc to 
install the necessary drivers for your computer’s operating system. 

Hardware Verification 

 

Verifying the RocketRAID mini-SAS 6G series controller is installed into the Mac Pro 
system:  

Step 1:

 Click on About this Mac  

Step 2:

 Click on More Info 

Step 3:

 Click on System Report  

Step 4:

 Click on PCI Cards  

Step 5:

 The RocketRAID mini-SAS 6G series controller will be identified as SCSI. 

Step 6: 

Verify the RocketRAID mini-SAS 6G HBA is detected and no drivers are 

installed. 

In Mac OS X 10. x ,the Driver Installed will be “No”.  

Once you have verified that the RocketRAID mini-SAS 6G series controller is 
detected you can proceed to the Driver and Software Installation.  

Содержание RocketRAID mini-SAS 6G HBA Series

Страница 1: ...cketRAID mini SAS 6G storage to support a Data RAID This guide also provides troubleshooting tips when problems occur Part 1 What is a Data RAID Configuration Part 2 Pre requisite for Data RAID Config...

Страница 2: ...acity of all the drives RAID 5 Stripe Protection Speed Data is striped like in a RAID 0 so significant speed gains are seen Protection Utilizes mathematical parity to achieve data protection while tak...

Страница 3: ...of all the drives used while for RAID 50 its usable space is each RAID5 capacity RAID5 number RAID 1 Mirror Speed No speed benefits gained Protection One drive can fail and all data will still be acce...

Страница 4: ...use a PCIe 2 0 slot running at x8 speeds or greater Slot recommendations for the RocketRAID mini SAS 6G series controller Mac Pro Model Core CPU Speed GHz EFI Slot Number 2006 Quad Core 2 0 2 66 3 0...

Страница 5: ...ing the RocketRAID mini SAS 6G series controller restart your computer After your computer has started insert the Driver Software Installation Disc to install the necessary drivers for your computer s...

Страница 6: ...wn the Mac Pro system then remove and insert the RocketRAID mini SAS 6G series controller then follow the steps from Hardware Verification Step 2 If Step 1 fails then insert the RocketRAID mini SAS 6G...

Страница 7: ...nsert the RocketRAID mini SAS 6G Card Install Disc into your Mac and navigate to the Mac OS X folder 2 Double click on the file to mount the disc image containing the Mac OS X software and drivers 3 D...

Страница 8: ...the after installing the software package and the Driver Installed is still No please try the following troubleshooting tips Step 1 Confirm that you have the RocketRAID mini SAS 6G series controller s...

Страница 9: ...ubleshooting steps to verify that the driver is install and that the RocketRAID mini SAS 6G series controller is detected Creating a Data RAID Once you have logged into the web GUI you are ready to cr...

Страница 10: ...Step 2 Initialize the drives before creating RAID...

Страница 11: ...Step 3 Select the hard drives attached to the RocketRAID mini SAS 6G series controller Step 4 Select the type of Data RAID you want to create RAID levels 0 1 5 6 10 50 and JBOD are supported...

Страница 12: ...Step 5 Confirmation that the Data RAID is created Step 6 Format the newly created partition...

Отзывы: