HighPoint RocketRAID 4500 Series Скачать руководство пользователя страница 20

 

20 

 

 

Staggered spinup: 

The default value of this option is disabled. Enabling this setting will instruct 
the card to power up the hard disks, sequentially (one disk approximately 
every 2 seconds).  Not all disk support this setting – consult the disk 
documentation for more information. 

Warning:  Western  Digital  hard  disks  do  not  support  this  setting.    Enabling 
this  setting  is  not  recommended.    If  enabled,  these  disks  may  not  be 
detected by non-RAID controller.

 

Number of drives per 
spinup: 

You can select the number of hard disk per spinup. 

Delay 

between 

spinup (seconds): 

Interval time between two continuous spinup. 

Spindown  Idle  Disk 
(minutes): 

Hard drives can be instructed to spin down when there is no disk activity for a 
set period of time. You are free to specify the interval – from 10 to 240 
minutes. 

Continue  Rebuilding 
on Error: 

Bad  sectors  can  cause  a  RAID  rebuild  to  stop.  This  option  will  ignore  bad 
sector  reading  and  let  the  rebuild  process  continue.  This  can  cause  data 
inconsistency in the future. By enabling this option it is recommended to view 
the Event log and look for HDD bad sector events. If bad sectors are found, it 
is then recommended that the HDD with bad sectors be fixed then reconnect 
the HDD back to the HBA 

Rebuild Priority: 

This option is provided for redundant arrays. This setting determines how HBA 
resources should be directed towards repairing broken RAID arrays. 

Single BCV entry: 

This setting may be useful for some motherboards, when booting from a disk 
or array attached to the RocketRAID HBA. 
When this setting is enabled (and if the card hosts several logical disks) only 
the first disk will be reported to the motherboard BIOS. 

INT 13 support: 

INT13 is the HBA’s boot function. It can be Enabled or Disabled. 

Stop on error: 

Enabled by default. If disabled, the host adapter BIOS menu will bypass array 
or device errors when booting the system. 

Auto Rebuild: 

If  enabled,  any  new  disk  attached  to  the  HBA  will  be  used  to  rebuild  the 
critical RAID array.  

Note:  The  new  disk  needs  to  be  equal  to  or  larger  than  the  minimum 
capacity among the remaining disk members of the array. 

Содержание RocketRAID 4500 Series

Страница 1: ...1 RocketRAID 4500 Series SAS SATA 6Gb s RAID Host Adapters User s Guide Revision 1 0 Oct 22 2012 HighPoint Technologies Inc...

Страница 2: ...not be registered trademarks or copyrights of their respective owners Backup your important data before using HighPoint s products and use at your own risk In no event shall HighPoint be liable for an...

Страница 3: ...2 Using the BIOS Utility 10 5 3 BIOS Commands 11 5 4 Creating RAID Arrays 11 5 5 Deleting Arrays 18 5 6 Adding Remove Spare Disks 18 5 7 Settings 19 5 8 View 21 6 RocketRAID 4500 Driver Installation 2...

Страница 4: ...advance features that the RAID Management software has to offer 1 Features and Specifications Hardware Specifications Marvell 88RC9580 RAID on Chip Processor 512MB DDR 3 Cache memory with ECC protect...

Страница 5: ...er based Management Interface Easy to use BIOS configuration Tool Linux Command Line Interface CLI Scriptable configuration tool Hot key ctrl h boot up RAID manager via BIOS Web browser based RAID man...

Страница 6: ...mm EMI FCC Part 15 Class B and CE Thermal and Atmospheric Characteristics Work Temperature Range 5 C 55 C Relative Humidity Range 5 60 non condensing Storage Temperature 20 C 80 C MTBF 920 585 Hours E...

Страница 7: ...7 3 Kit Contents RocketRAID 4522 HBA RocketRAID 4520 HBA Quick Installation Guide HighPoint Software CD Low Profile Bracket Two mini SAS cables SFF 8087 to 4 SATA RocketRAID 4520 only...

Страница 8: ...connector J6 BBU connector A1 A2 Active LED PIN N A F1 F2 Fail LED PIN N A PORT1 PORT2 Mini SAS Port SFF 8087 Mini SAS Port SFF 8088 Active FAIL LED PIN connector The LED connectors are designed for...

Страница 9: ...s 4 After installing the adapter attach the hard disks or backplane enclosure to the host adapter using the mini SAS cables Note Many server level chassis include hard drive hot swap bays For these sy...

Страница 10: ...s the RocketRAID 4500 adapter s BIOS Utility 5 1 BIOS Settings Overview The RocketRAID 4500 controller BIOS utility is an interface that provides management commands and controller related settings We...

Страница 11: ...opens the settings menu To selecting the boot disk array staggered drive spinup etc View This command is used to view hard disk and RAID information Initialize This command is used to prepare disks fo...

Страница 12: ...press ESC key The utility will display a warning and ask you to press Y yes to initialize or N no to cancel Once initialized these disks can be used to create RAID arrays These disks will be displaye...

Страница 13: ...arrow keys to highlight the Array Name option and press Enter key The array name dialogue box will appear Use the keyboard to input a new Array Name and press the Enter key Note the Array Name comman...

Страница 14: ...e Menu 5 Next Use the arrow key to highlight the Capacity GB option and press Enter key The total available capacity will be displayed Press Enter key if you wish to use all available space If you wis...

Страница 15: ...is option if you are using an older 32 bit Windows operating system This allows older operating systems to support volumes over 2TB in size Do not use if the operating system already supports large vo...

Страница 16: ...is option is used to assure data safety and avoid operation errors causing data lose to the original disk B This option does not initialize the array disk New disks can be used to create a RAID withou...

Страница 17: ...on the disks B The initialization time will be shorter time compared to the Background option The logical disks will not be reported to the OS until the initialization is complete Background The RAID...

Страница 18: ...rray contains critical data 5 6 Add Remove Spare Disks This Add Remove Spare command is used to assign a hard disk to act as a Spare Disk Spare Disks are used to automatically rebuild Redundant RAID a...

Страница 19: ...t of a grand total of 400GB was assigned to that array In this example 200GB of disk space remains unallocated This unallocated space would allow these disks to be set as spares for a separate redunda...

Страница 20: ...e This can cause data inconsistency in the future By enabling this option it is recommended to view the Event log and look for HDD bad sector events If bad sectors are found it is then recommended tha...

Страница 21: ...l sound 5 8 View The View menu provides four options Devices This option will display information for each disk hosted by the HBA RAID Array This option will display information about each RAID array...

Страница 22: ...22 Controller Select this option to view information about the RocketRAID HBA...

Страница 23: ...23 Rescan Devices This command will prompt the HBA to scan each port for devices Use this feature when attaching hard disks or arrays to the HBA...

Страница 24: ...ll the RocketRAID 4500 host adapter into the PC then boot up the Windows operating system 2 Windows will detect the RocketRAID 4500 HBA and automatically search for the driver 3 If Windows is unable t...

Страница 25: ...lick the Setup exe icon 6 The HighPoint Software Install window should be displayed Click the Install Driver button The interface will install the RocketRAID 4500 driver automatically 7 Once complete...

Страница 26: ...26 8 After rebooting the system the RocketRAID 4500 HBA will be recognized by Device Manager and listed under Storage Controllers...

Страница 27: ...m the Windows Installation DVD 2 When the following window is displayed please insert the HighPoint software CD into the CD DVD drive Select Load Driver item 3 Browse to the following software CD fold...

Страница 28: ...y the following entry after locating the driver Click Next to install the RocketRAID 4500 driver Installing the driver manually using Device Manager 1 The RocketRAID 4500 HBA will be recognized as a R...

Страница 29: ...29 2 Select Browse my computer for driver software in the popup window 3 Browse to the following Software CD folder Driver RR452x Windows Select x32 or x64 according with your windows OS...

Страница 30: ...30 4 Follow the InstallShield Wizard s prompts to install the RocketRAID 4500 driver Click Close to exit the Wizard once the driver has been successfully installed...

Страница 31: ...e included with the driver packages for the more information Linux driver packages are included with the Software CD Driver RR452x Linux Before Installing make sure you have the latest driver updates...

Страница 32: ...Installing Uninstall the Web RAID Management Software Microsoft Windows Install the Web RAID Management Software 1 Insert the HighPoint software CD into the CD DVD drive The program should start autom...

Страница 33: ...33 3 Follow the InstallShield Wizard s prompts to install the HighPoint RAID Management interface...

Страница 34: ...estrict the HighPoint RAID Management interface to the local network the RocketRAID HBA cannot be managed remotely 5 Click the Finish button to complete the installation procedure 6 Important The inte...

Страница 35: ...not you can start it manually by running net start hptsvr under a Windows command prompt If you can t connect to a remote system check if hptsvr is running on that system and you can access the remote...

Страница 36: ...Software location RocketRAID Software CD Management_Software RocketRAID_series Web_RAID_Management Linux Before Installing make sure you have the latest driver updates Visit the HighPoint website for...

Страница 37: ...w highpoint tech com website to download the latest firmware 2 Extract the download to a bootable DOS USB drive 3 Boot the system using the bootable USB drive 4 At the command prompt access the firmwa...

Страница 38: ...38 9 Thank You Thank you for purchasing the RocketRAID 4500 SAS SATA RAID Host adapter We appreciate your support and welcome any questions comments or product suggestions you may have...

Страница 39: ...RAID series host adapters or have any questions about this or any other HighPoint Technologies Inc product feel free to contact our Customer Support Department HighPoint Technologies Inc websites http...

Отзывы: