Introduction
I-11
Intr
oduc
tion
Lamp
Lamp type:
Use only M Series, GX 9.5 base, 575
watt, metal halide type lamp
MSR 575/2 color temperature:
6200° Kelvin
MSD 575 color temperature:
5600° Kelvin
WARNING:
Use only the lamps purchased from High End Systems. These lamps
were specifically designed for use in Studio Color.
Communication
Protocol:
USITT DMX-512
Start code:
00h
Maximum load:
32 fixtures per DMX link
Required channels:
16
Termination:
120
Ω
Compliance
Studio Color 575-M and 575-S are compliant to the following standards:
•
UL 1572
•
CSA 22.2 Number 9
•
EN 60598-1 : 1993
•
EN 60598-2-17 : 1989 A1-A3 : 1993
•
EN 55022, Class A ITE
•
IEC 801-2, 1991 Level 2 (4/8 kV)
•
IEC 801-3, Draft 5 Level 2 (3 V/m)
•
IEC 801-4, 1988 Level 2 (1 kV/0.5 kV)
•
FCC-Class A digital device
Available Controllers
The following controllers from Lightwave Research® may be used to operate
Studio Color:
Wholehog III
Lighting Console
Hog2 PC controller
Additionally, most DMX-512 controllers may be used to operate Studio Color.