background image

-3-

 H

(psi)

     

18

36

54

72

0  

90 m

3

/h

0

300

600

900

1200

1500 l/min

4

8

12

16

6

12

18

24

  80 

Performance curves

 160       240        320        400      480     U .S .GPM

  400 

I

  

M

  

P

  

.

  

G

  

PM

 80 

  160 

  240 

 320 

10

20

30

40

50

 

H

 

(ft)

 

H

 

(m)

60

20

30

70

Head

Flow

HIDRO-HMT750(HM)

550(HM)

400(HM)

350(HM)

300(HM)

-Is  the  proper  voltage  applied  to  the  pump?
-Is  there  an  extension  cord  being  used?

-Is  the  air switch  hose  connected  to  the  pump?
-Is  the  air switch  hose  connected  to  the  actuator

button  on  the  tub  deck?

-Jets  should  be  pointed  away  from  the  suction

inlet  so  air  is  not  forced  into  pump  suction

-Is  the  in-tub  suction  inlet  blocked  or  covered?
-Is  there  any  debris  in  the  pump  housing?
-Is  there  a  leak  in  the  piping  or  the  pump?

-incoming  power  to  the  pump?
-Is  circuit  breaker  on?
-Is  GFCI  operating  properly?
-Is  the  air switch  plugged  in?

AIR SWITCH 

DISCONNECTED

NO  POWER  

TO  PUMP

  

PUMP DOES 

 NO  TURN 

BLOCKAGE  OR  

LEAK

LOW  VOLTAGE

PUMP  NOT

PUMPING

PROPERLY

SYMPTOM

POSSIBLE CAUSE

CHECK

7.Maintenance and clean

   Our  pumps  for hydromassage  facilities  do not  require  any special maintenance  or  programming. 

           If the pump will be  idle for a long period of time, it is recommended to disassemble, clean and  store 

it  in a dry, well-ventilated place. If  the  supply cord is damaged, it  must  be  replaced by the manufacturer or its

  

serv

           

ice agent or a similarly qualified person  to a hazard.

  

Pump 

             

can be automotive empty water after correct installation.

   

When  the pump  needs  to  clean (1)  filling  with  water up  to  level  position  of  bathtub`s nozzle, (2) operating  

 

2-3mimute,(3) exhausting water of bathtub after engine stop.
  

8.Trouble Shooting

  

Guide

Отзывы: