8.- RECAMBIOS EQUIPO DE ULTRAFILTRACIÓN 
 

9.1.- Recambios Equipo de Ultrafiltración. 

 

Nº 

CÓDIGO 

DESCRIPCIÓN 

UDS 

OI-0207-139 

” WATER STOP Antileak system. 

OI-0207-141 

” Pressure reducer 40psi 

OI-0210-03 

¼” M x 

” T Brass ball valve  

 

1/4" Elbow quick connection 

OI-0230-09 

” M x ¼” F x 

” F Feed adapter 

OI-0208-24 

” tube faucet adapter 

OI-0207-64 

New Look faucet 

OI-0207-54 

” plastic insert 

TU-0602-01 

” Tube 

10 

 

ATHENEA Ultrafiltration system support bracket 

11 

OI-0235-02 

QC3 cartridge cups.   

12 

OI-0208-16 

¼” M x 

” T Straight 

13 

OI-0208-04 

¼” M x ¼” M Double Male connector 

14 

CA-0218-03  QC3 Antibacterial sediments cartridge  

15 

CA-0218-05  QC3 Carbon Block CTO cartridge 

16 

ME-0218-04  Ultrafiltration membrane 

17 

CA-0218-06  QC3 NANOSILVER Antibacterial cartridge 

18 

OI-0207-133  Absorbent material 

19 

 

3/8" Elbow quick connection fitting 

20 

 

 1/4" quick connector 

21 

 

ATHENEA system back part 

 

22 

 

ATHENEA system front part 

 

 
 
 
 
 
 

Содержание ATHENEA

Страница 1: ...tion 5 4 3 Ultrafiltration instllation 5 5 ULTRAFILTRATION SYSTEM START UP 7 6 INSTRUCTIONS AND MAINTENANCE 8 6 1 Procedure for replacing cartridges and the membrane 9 6 2 Procedure for replacing the WATER STOP anyileak absorbent material 10 7 FAULTS PROBABLE CAUSES AND POSSIBLE SOLUTIONS 11 8 SPARE PARTS 14 9 MONITORING AND MAINTENANCE CONTROL 12 9 1 Ultrafiltration spare parts 12 ...

Страница 2: ... not be below 4ºC nor above 40ºC to avoid damaging the system The ultrafiltration system is designed to treat tap water with a maximum salinity of 1500 ppm Do not use in places where the water is not microbiologically safe or has an unknown quality For water with a greater salinity level please con tact an official HIDRO WATER S L distributer It is advisable that the water to be treated has been s...

Страница 3: ...ormance of the system For installation maintenance and cartridge change please follow this manual otherwise the warranty will be void 3 CHECKING THE CONTENTS Open the packaging and make sure that all of the components are inside ready for the installation Figure Description 1 ATHENEA ultrafiltration system main unit 2 New Look Faucet 3 PE Tube 4 Feed adapter 5 M x T ball valve 6 plastic insert 7 f...

Страница 4: ...nd sufficient space to be located The most common place is under the kitchen sink The installation should be carried out by qualified per sonnel onnel 4 1 Faucet installation Figure 2 a Choose the location on the counter where you want to install the faucet b Use a drill with a 12mm bit to make a necessary sized hole to put the faucet c Fit the tap in the hole as indicated in the fig ure using a s...

Страница 5: ...l trafiltration system will be damaged Make sure that the brass ball valve is closed 4 3 Ultrafiltration system installation The hydraulic connections should follow the contour of the surface cho sen for installation so that the tubes do not get mixed up or tangled Leave a suf ficient length of tube to ease moving the system during future maintenance Here are the steps to follow to make the hydrau...

Страница 6: ...ration system Figure 1 where it s marked IN inserting it fully Once inserted place the security clip on it e Screw the faucet adapter figure 7 to the faucet plac ing the supplied O Ring between the adapter and the stud Insert tube through this adapter s nut and sleeve then insert a plastic insert Figure 6 in that end on the tube Then you must insert that end in the faucet s adapt er and tighten th...

Страница 7: ...ater leak If there is close the valve and fix it e Open the faucet Figure 2 and let all of the air out from inside the ultra filtration system Once a continual water flow comes out of the faucet let it run for 30 seconds and then close the faucet If in the beginning the water runs black don t worry this is normal it s caused by the resi due that the granulated carbon filter lets off Drain this wat...

Страница 8: ... and the correct operation of the osmosis system the war ranty will be void Cartridge type Antibacterial Sediments cartridge Carbon CTO cartridge Ultrafiltration membrane Nanosilver Carbon cartridge Stage 1st 2nd 3rd 4th Reference CA 0218 03 CA 0218 05 CA 0218 04 ME 0218 06 Appearance Replace 6 9 month 6 9 months 1 2 years 6 9 months Sanitation Every time you change a cartridge the membrane or a c...

Страница 9: ...se and pulled downwards to remove it from its cap as indicated in the follow ing figure This process must be carried out for each of the cartridges that you want to replace d Remove the cartridges membrane from their original packaging Each car tridge and or membrane must be placed in the correspond ing position main taining the correct order To do so you must insert each cartridge in its cap and ...

Страница 10: ...e are any close the valves and fix them Precaution 1 If there is any water leak in any area of the tube connections re move it and cut off 0 5cm Then reconnect it If the leak s produced on any thread unscrew the piece apply more Teflon and screw it back on 6 2 Procedure for replacing the WATER STOP antileak absorbent material In the case of having to change the WATER STOP Antileak absorbent materi...

Страница 11: ...t valve fully c Replace cartridges d Replace membrane e Check if the Antileak system has been activated If so find the leak and fix it change the absorbent material and lower the arm on the Antileak system 2 Plastic or synthetic taste a Worn Nanosilver Carbon cartridge a Replace cartridge 3 Chlorine taste and smell a Worn cartridges a Change the cartridges 4 Unpleasant taste and smell a Contaminat...

Страница 12: ...ew Look faucet 1 8 OI 0207 54 plastic insert 2 9 TU 0602 01 Tube 1 10 ATHENEA Ultrafiltration system support bracket 1 11 OI 0235 02 QC3 cartridge cups 4 12 OI 0208 16 M x T Straight 2 13 OI 0208 04 M x M Double Male connector 3 14 CA 0218 03 QC3 Antibacterial sediments cartridge 1 15 CA 0218 05 QC3 Carbon Block CTO cartridge 1 16 ME 0218 04 Ultrafiltration membrane 1 17 CA 0218 06 QC3 NANOSILVER ...

Страница 13: ...ref MA UF 0002 EN V14 0 ATHENEA pdf 13 1 2 3 5 4 6 7 8 9 10 11 12 11 11 11 13 14 15 16 17 18 19 20 21 22 ...

Страница 14: ...CTO cart change Membrane change Post filter change Sanitization Reparation Name and signature of the authorised technician or distribu tor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Membrane change Post filter change Sanitization Reparation Name and signature of the authorised technician or distribu tor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CT...

Страница 15: ...mbrane change Post filter change Sanitization Reparation Name and signature of the authorised technician or distribu tor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Membrane change Post filter change Sanitization Reparation Name and signature of the authorised technician or distribu tor DATE SERVICE MADE NEXT SERVICE OBSERVATIONS Sediments GAC y CTO cart change Memb...

Страница 16: ...ref MA UF 0002 EN V14 0 ATHENEA pdf 16 ...

Отзывы: