INSTALLATION, MAINTENANCE AND USER'S GUIDE

FAN WITH ELECTRONICALLY COMMUTATED EXTERNAL-ROTOR MOTOR

Fan Code:

0314-4-0166

Fan type : R14R-63APS-ET80B-10C17

&

Note :

Table of Contents :

01

SAFETY

02

TYPICAL FEATURES AND PROPER USE

03

OPERATING CONDITIONS

04

INSTALLATION AND CONNECTION

05

SPEED CONTROL

06

PUTTING INTO OPERATION

07

DIAGNOSTICS & TROUBLESHOOTING

08

PROTECTIVE FEATURES

09

MAINTENANCE, SERVICE AND CLEANING

10

TRANSPORT AND STORAGE

11

ErP, ROHS AND EMC DIRECTIVES

12

SERVICE ADDRESSES AND ADDITIONAL DATA

Be sure to familiarize yourself with these instructions before working on this unit. Not paying attention to these warnings
and instructions may lead to malfunctions and failures or may seriously endanger human life.

Symbols :

WARNING - to indicate warning situation 

NOTE - indicate valuable information

Содержание 0314-4-0166

Страница 1: ...G INTO OPERATION 07 DIAGNOSTICS TROUBLESHOOTING 08 PROTECTIVE FEATURES 09 MAINTENANCE SERVICE AND CLEANING 10 TRANSPORT AND STORAGE 11 ErP ROHS AND EMC DIRECTIVES 12 SERVICE ADDRESSES AND ADDITIONAL D...

Страница 2: ...nnot cause serious damage or bodily harm Do not operate this appliance in an explosive atmosphere Fan must be fixed to stationary housing with appropriate screws according to this guide This appliance...

Страница 3: ...s appliance is not intended to be built as a partition fan mounting in outside windows or walls unless it is built into an end application which is designed for that purpose The fan is intended to be...

Страница 4: ...53 5 Installation category A Efficiency category static Efficiency grade N 60 3 Variable speed drive INTEGRATED Power Input Pelec 858 5 W Airflow volume qV 9867 m h Pressure Increase ps 161 Pa Rotati...

Страница 5: ...that the air gap between the fan impeller and the stationary housing is constant Distortion due to an uneven surface of basis may lead to a fan failure Air gap between blade and cone inlet housing sh...

Страница 6: ...ss of water or moisture inside the terminal box If the cable is not installed through the cable gland sealing plug must remain in the gland Secure connection cable to the fan guard grill or to the mot...

Страница 7: ...ighest system pressure reached at maximum load is 16Bar 8V For optimal operation of the application the fan mounted on a condenser should run at max speed at 8V of input control voltage In order to ac...

Страница 8: ...upply voltage inadequate control signal or fan overheating Check line voltage check control signal check temperature and sufficient airflow of cooling air or loss of motor cooling Attention In the eve...

Страница 9: ...orce for the cable s When transporting fans mounted on final units apparatus take care that they are properly secured and don t touch other devices which are transported near or on to Store the fans i...