background image

INSTALLATION GUIDE

hidglobal.com

An ASSA ABLOY Group brand

This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output 

are fictitious. Specifications are subject to change without notice.

© 2014 - 2015 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS SE are trademarks or registered trademarks of HID Global in the U.S.  

and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners. 

13056 MHz Contactless

iCLASS SE® / multiCLASS SE® 

R10E, RP10E, R15E, RP15E, R30E, RP30E, R40E, RP40E, RK40E, RPK40E 

R10MA, RP10MA, RP15MA, R40MA, RP40MA, RPK40MA

Parts

1 - iCLASS SE/multiCLASSS SE Reader
1 - Installation Guide
2 - #6-32 x .375” Phillips machine screws
3 - #6-32 x .375” spanner security screw
2 - 7-pin Terminal connectors
1 - 10-pin Terminal connector
1 - Mounting gasket
1 - Back box

Specifications

PRODUCT

BASE PART 

NUMBER

INPUT 

VOLTAGE (VDC)

CURRENT

1

OPERATING 

TEMPERATURE

5

CABLE LENGTH

6

REGULATORY

REF 

NUMBER

Standby 

AVG

2

Max 

AVG

3

PEAK

4

R10

7

900N

5 - 16VDC 

12VDC for RS-485

60mA 95mA

200mA

-30° to 150° F

(-35° to 65° C)

Communication Lines 

Wiegand

 = 500 ft - 22 AWG

 

      (152 m)

 

      300 ft - 24 AWG

 

        (91 m)

     RS-485 

= 4000 ft - 4 AWG

 

       (1,219 m)

R10E

x

1

x

2

x

3

RP10

7

900P

75mA 100mA

RP10E

x

1

x

2

x

3

900L

110mA 135mA

R15

910N

60mA 95 mA

R15E

x

1

x

2

x

3

RP15

7

910P

75mA 100mA

RP15E

x

1

x

2

x

3

910L

110mA 135mA

R30

930N

65mA 95mA

R30E

x

1

x

2

x

3

RP30

930P

85mA 100mA

RP30E

x

1

x

2

x

3

930L

120mA 145mA

R40

7

920N

65mA 95mA

R40E

x

1

x

2

x

3

RP40

7

920P

85mA 100mA

RP40E

x

1

x

2

x

3

920L

120mA 145mA

RK40

921N

5.5 - 16VDC 

12VDC for RS-485

85mA 100mA

220mA

RK40E

x

1

x

2

x

3

RPK40

7

921P

95mA 105mA

RPK40E

x

1

x

2

x

3

921L

130mA 155mA

Recommended

•  Cable, 5-9 conductor (Wiegand or Clock-and-Data)
•  Linear DC power supply
•  Metal or plastic junction box
•  Security tool (for anti-tamper screw) HID 04-0001-03
•  Drill with various bits for mounting hardware
•  Mounting hardware

PLT-01579 A.3

PART NUMBER

INPUT VOLTAGE (VDC)

CURRENT

OPERATING TEMPERATURE

FREQUENCY

FCC & IC IDs

Standby AVG

PEAK

MDP-00870

3.3VDC

22mA

40mA

-15° to 150° F (-25° to 65° C)

2.4 - 2.480 GHz

FCC-ID: JQ6-ICLASSBTM
IC-ID: 2236B-ICLASSBTM

The final product, containing the modular transmitter must be labeled with its own FCC ID and IC ID.  If the FCC & IC ID is not visible, when the module 

is installed inside another device, then the final assembly label must contain the FCC and IC ID numbers with a statement such as follows: “Contains 

Transmitter Module with FCC ID JQ6-ICLASSBTM and IC ID 2236B-ICLASSBTM”.

BTSmart Module Specifications

UL Reference Number Deciphering

x

1

  Reader Colors:

 

K = Black

 

x

Wiring: 

 

N = Pigtail

 

T = Terminal

 

     

5 = 5 meter Pigtail

x

Communications: N = No Module,

 

     

R = RS-485 (OSDP)

 

     

L = Indala Prox

 

     

B = Bluetooth

Communication protocols other than Wiegand or Clock & Data 

(for control panels), as well as credential interfaces over BLE 

(not applicable for 9xxL models), require an additional hardware 

module which increases current by 30mA.

Standby AVG - RMS current draw without a card in the RF field.

Maximum AVG - RMS current draw during continuous card reads. 

Not evaluated by UL.

Peak - highest instantaneous current draw during RF communication.

When configured for Bluetooth Operating Range is -13° to 150° F 

 

(-25° to 65° C)

Wiegand Cable Lengths:

 

100 ft (30.5 m) 22 AWG @ 5 - 6.4VDC

 

500 ft (152 m) 22 AWG @ 6.5 - 16VDC

Mobile Enabled Products, see specifications below.

Содержание R10E

Страница 1: ...1 x2 x3 920L 120mA 145mA RK40 921N 5 5 16VDC 12VDC for RS 485 85mA 100mA 220mA RK40Ex1 x2 x3 RPK407 921P 95mA 105mA RPK40Ex1 x2 x3 921L 130mA 155mA Recommended Cable 5 9 conductor Wiegand or Clock and...

Страница 2: ...ts of an installation Configuration options include audio visual CSN outputs and keypad outputs keypad models only Contact HID Technical Support for all reader configuration options Hold Input when as...

Страница 3: ...5Ex1 x2 x3 910L 110 mA 135 mA R407 920N 65 mA 95 mA R40Ex1 x2 x3 RP407 920P 85 mA 100 mA RP40Ex1 x2 x3 920L 120 mA 145 mA RK40 921N 5 5 16 VCC 12 VCC para RS 485 85 mA 100 mA 220 mA RK40Ex1 x2 x3 RPK4...

Страница 4: ...modelos com teclado Contate o Suporte t cnico da HID para todas as op es de configura o do leitor Entrada de reten o quando ativada esta linha armazena um cart o em buffer ou desativa a leitura de um...

Страница 5: ...t accept any interference including interference that may cause undesired operation of the device Le pr sent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de...

Страница 6: ...For more information consult ANATEL website www anatel gov br RF Warning Statement Per Article 6 of Resolution 506 equipment of restricted radiation must carry the following statement in a visible loc...

Страница 7: ...dos Este equipamento opera em car ter secund rio isto n o tem direito a prote o contra interfer ncia prejudicial mesmo de esta es do mesmo tipo e n o pode causar interfer ncia a sistemas operando em c...

Страница 8: ...0E RK40E RPK40E Page 8 INSTALLATION GUIDE iCLASS SE multiCLASS SE PLT 01579 A 3 R10E RP10E R15E RP15E R30E RP30E R40E RP40E RK40E RPK40E R10MA RP10MA RP15MA R40MA RP40MA RPK40MA HID Global Americas Co...

Страница 9: ......

Отзывы: