_____________________________________________________________________________________________________
HID Corporation 9292 Jeronimo Road Irvine, CA 92618-1905 USA TEL (949) 598-1600 (800) 237-7769 FAX (949) 598-1690
Web page, E-mail - www.hidcorp.com - Miniprox Installation Manual 5365-910 Rev 1
2
PARTS LIST (Included)
Quantity
- Miniprox
TM
Reader with snap-on cover and 18” cable
(For terminal block versions no cable is supplied)
1
- #6-32 x 1” self-tapping panhead screw
2
- Installation manual
1
- Junction box (Hazardous installation version only)
1
PARTS LIST (Not-Included)
Quantity
- Wire splice
9
- DC Power supply 5.0 VDC or 12 VDC
2
Mounting Instructions
•
Determine an appropriate mounting location. The
reader may be mounted to any surface, including
metal.
•
Drill two (2) 3/32-inch (2.5mm) holes approximately
1 inch deep for mounting the reader.
•
Drill a 5/8-inch (16mm) hole for the cable.
•
Remove the snap-on cover from the reader and
secure the reader to the mounting surface.
•
Route the cable from the reader and/or power
supply to the host. A linear type power supply is
recommended. Check all electrical codes for proper
cable installation.
•
For best operation, the drain wire should be
disconnected at the power supply end of the cables.
•
For the cable connection to the Panel - Use Alpha
#1299C or equivalent.
•
Test the operation of the reader. After completion of
the test, replace the snap-on cover.
•
See sheet 3 of this manual for the appropriate
dimensioned drawings.
Connecting the Reader to the Host
Connect the reader to the host according to the wiring
table below and the host installation guide.
Wiegand
Clock & Data
Wire Color
Terminal Number
+DC
+DC
Red
TB1-1
Ground
Ground
Black
TB1-2
Data0
Data
Green
TB1-3
Data1
Clock
White
TB1-4
Shield Ground
Shield Ground
Drain
TB1-5
Green LED
Green LED
Orange
TB1-6
Red LED
Red LED
Brown
TB1-7
Beeper
Beeper
Yellow
TB1-8