HID Mercury MR52-S3 Скачать руководство пользователя страница 16

UL294, 6

th

 edition Performance Levels

Feature

Level

Standby Power

I

Endurance

IV

Line Security

I

Destructive Attack

I

These specifications are subject to change without notice.

3.1 Warranty

Mercury Security warrants the product is free from defects in material and workmanship under normal use 
and service with proper maintenance for one year from the date of factory shipment.  Mercury Security 
assumes no responsibility for products damaged by improper handling or installation.  This warranty is limited 
to the repair or replacement of the defective unit.

There are no expressed warranties other than set forth herein.  Mercury Security does not make, nor intends, 
nor does it authorize any agent or representative to make any other warranties, or implied warranties, and 
expressly excludes and disclaims all implied warranties of merchantability or fitness for a particular purpose.

Returns must be accompanied by a Return Material Authorization (RMA) number obtained from customer 
service, and prepaid postage and insurance.

3.2 Liability

The Interface should only be used to control exits from areas where an alternative method for exit is 
available.  This product is not intended for, nor is rated for operation in life-critical control applications.  
Mercury Security is not liable under any circumstances for loss or damage caused by or partially caused by 
the misapplication or malfunction of the product.  Mercury Security’s liability does not extend beyond the 
purchase price of the product.

3.3 Regulatory

This device complies with part 15 of the FCC Rules.  Operation is subject to the following two conditions: (1) 
This device may not cause harmful interference, and (2) this device must accept any interference received, 
including interference that may cause undesired operation.

PLT-05248, A.2

16

June 2021

Powering

Trusted Identities

HID Mercury™ MR52-S3 Reader Interface

Installation and Specifications

Содержание Mercury MR52-S3

Страница 1: ...HID Mercury MR52 S3 Reader Interface Installation and Specifications PLT 05248 A 2 June 2021 HID Mercury MR52 S3 Reader Interface Installation and Specifications Powering Trusted Identities...

Страница 2: ...ical Support www hidglobal com support Americas and Corporate Asia Pacific 611 Center Ridge Drive Austin TX 78753 USA Phone 1 866 607 7339 19 F 625 King s Road North Point Island East Hong Kong Phone...

Страница 3: ...Section 01 Powering Trusted Identities Overview...

Страница 4: ...be used for strike control or alarm signaling Eight inputs are provided that can be used for monitoring the door contact request to exit push button and alarm contacts Input circuits can be configure...

Страница 5: ...Section 02 Powering Trusted Identities MR52 wiring and setup...

Страница 6: ...D Mercury Security intelligent controller EP2500 for example via a 2 wire RS 485 interface The MR52 allows for multi drop communication on a bus of up to 4 000 feet 1 200 m Use twisted pair minimum 24...

Страница 7: ...Use one cable for power 18 AWG and one cable for communication 24 AWG with drain wire and shield Note For OSDP cable lengths greater than 200 ft 61 m or EMF interference install 120 2 resistor across...

Страница 8: ...reader 2 Wiegand or Clock Data installation Typical Unsupervised F 2F Reader Typical Supervised F 2F Reader Jumper D1 to LED on supervised F 2F readers Inputs on supervised F 2F readers may be unsuper...

Страница 9: ...s possible Custom end of line EOL resistances can be configured via the host software Grounded and foreign voltage states are not a requirement of UL 294 and therefore not verified by UL The input cir...

Страница 10: ...e effectiveness of the circuit will decrease if it is located further away Use sufficiently large gauge of wires for the load current to avoid voltage loss Diode selection n Diode current rating 1x st...

Страница 11: ...ON Address 9 OFF ON OFF ON OFF Address 10 OFF ON OFF ON ON Address 11 OFF ON ON OFF OFF Address 12 OFF ON ON OFF ON Address 13 OFF ON ON ON OFF Address 14 OFF ON ON ON ON Address 15 ON OFF OFF OFF OF...

Страница 12: ...nication not required2 ON Encrypted communication required2 1 Firmware revisions prior to 1 38 1 this setting is 2 400 BPS 2 Firmware revisions prior to 1 38 1 SW8 is not defined Set to the OFF positi...

Страница 13: ...ED Input Status IN6 7 LED Input Status IN7 8 LED Input Status IN8 TMP Cabinet tamper PFL Power fault Input in the inactive state OFF briefly flashes ON every 3 seconds Input in the active state ON bri...

Страница 14: ...Section 03 Powering Trusted Identities Specifications...

Страница 15: ...TTL compatible high 3 V low 0 5 V 5 mA source sink maximum Buzzer output Open collector 12 V DC open circuit maximum 40 mA sink maximum Communication 2 wire RS 485 9600 19200 38400 or 115200 bps Cable...

Страница 16: ...tness for a particular purpose Returns must be accompanied by a Return Material Authorization RMA number obtained from customer service and prepaid postage and insurance 3 2 Liability The Interface sh...

Страница 17: ...2021 Minor updates A 2 April 2021 Added reader power select table in 2 3 Reader wiring A 1 October 2020 Initial release A 0 PLT 05248 A 2 17 June 2021 Powering Trusted Identities HID Mercury MR52 S3 R...

Страница 18: ...a Pacific 19 F 625 King s Road North Point Island East Hong Kong Europe Middle East Africa 3 Cae Gwyrdd Green Meadow Springs Cardiff CF15 7AB United Kingdom Brazil Condom nio Business Center Av Ermano...

Отзывы: