background image

Page 26

 

PLT-01952, Version: A.2

June 2015

5.10.1

To Change the Password

1.

Select the 

Network Setting

s tab.

2.

Enter a new password in the 

Change User Password

 field.

3.

Re-enter the new password in the 

Confirm User Password 

field.

4. Click 

Apply Changes

.

5.

Test the new password, by clicking the 

Reboot System

. Log into the reader with the new 

password.

Note:

 If the password has been lost, see 

Section 6: Restore Default Settings

 for instructions to reset 

the password to the default setting.

Confirm User Password

Confirm the new password for the device.

Apply Changes

The Apply Changes button will apply any of the changes that have been made 
to the configuration (fields will be green) and save them to the configuration. 
Once saved the green fields should turn back to black.

Field

Description

Содержание iCLASS SE U90 Series

Страница 1: ...hidglobal com iCLASS SE U90 Reader User Guide PLT 01952 Version A 2 June 2014...

Страница 2: ...nd the world see www hidglobal com corporate offices Date Description Version 12 16 14 Initial release A 1 10 10 14 Beta release A 0 Americas and Corporate Asia Pacific 611 Center Ridge Drive Austin T...

Страница 3: ...ical Installation 5 3 1 Reader Position 5 3 2 Installation to the Mounting Surface 6 3 3 Wiring 8 3 4 Installing the Reader to the Backbox 9 3 5 Initial Aiming 10 3 6 Installation Examples 10 4 Setup...

Страница 4: ...LT 01952 Version A 2 June 2014 5 9 Firmware Tab 24 5 10 Network Settings Tab 25 5 10 1 To Change the Password 26 6 Restore Default Settings 27 7 Credential Location 28 7 1 Installation 28 8 Troublesho...

Страница 5: ...3 each dry relays for operating external audio and visual indicators Rated 30VDC 2A Resistive Flexible configuration using Ethernet port and local web portal IP65 and UL294 outdoor ratings 1 2 Specif...

Страница 6: ...eflect radiated energy which can have the effect of boosting power or sensitivity along any number of axes The combination of the characteristics listed above lead to the following ideal installation...

Страница 7: ...n angle the reader as appropriate see lane drawing Avoid mounting two readers too close back to back as shown in Section 2 1 1 2 Lane Configuration This could result in one reader interfering with the...

Страница 8: ...ed to be installed at a optimal hight and angle to read the cards properly Wall Post 2 1 1 5 Interference objects radio lights An obstruction free area is required for optimal performance 2 1 2 Tools...

Страница 9: ...pen air applications with a mix of cars and full size trucks The reader should be positioned near the edge of the vehicle lane but located such that it cannot be struck by passing vehicles The reader...

Страница 10: ...2 Mounting holes need to be drilled in the back plate to mate with the mount selected for the site Note Basic holes are marked and labeled 3 Drill the hole for the conduit identified below Note The c...

Страница 11: ...e square opening shown below Note This is done with scissors 5 It is recommended that the gasket be modified to match the area between the mount and the box to create a seal against the elements examp...

Страница 12: ...P1 4 VDC P2 4 Wiegand Data 1 Clock DATA1 CLK P3 4 Normally Open NO Relay 1 P1 5 Unused DRAIN P2 5 Open Collector Output Tamper OC TMPR P3 5 Normally Closed NC Relay 2 P1 6 LED Input RED P2 6 GPIO2 RS2...

Страница 13: ...to the Backbox 1 Install the reader to the backbox It is hinged on the top and should fit snugly at the bottom Note The sides of the Reader will snap as the features align 2 Use the 2 screws that wer...

Страница 14: ...in the center of the vehicle lane 6meters 20 feet from the reader This will result in approximately a 20 downward angle This setting will work in most applications Fine adjustments can be made during...

Страница 15: ...er Settings tab See Section 5 U90 Reader Management Configuration for detailed information on the GUI configuration windows 2 Select the General tab and select the appropriate region from the Region d...

Страница 16: ...ted to an angle to properly read credentials located on the vehicles windshields 2 Once the reader is properly angled it must be tested Initially you could walk through the lane with a credential to p...

Страница 17: ...s been modified to an acceptable level and has been implemented in the reader however the change has been stored in temporary memory and will be lost if the reader is re booted either through a power...

Страница 18: ...e changed as soon as possible for security reasons See Section 5 7 Reader Information Tab for information on this process 5 5 Update Firmware To update the U90 firmware use the following 1 Select the...

Страница 19: ...Main Window The U90 Reader Management GUI consists of the following tabbed Sections Note The following are links to the sections in this guide Reader Information Tab Reader Settings Tab General Tab I...

Страница 20: ...s Displays the MAC address of this unit SAM Firmware Version Displays the current Secure Application Module SAM firmware version User Password This field allows the user to change the User Password Th...

Страница 21: ...Apply Changes The Apply Changes button will apply any of the changes that have been made to the configuration fields will be green and save them to the configuration Once saved the green fields shoul...

Страница 22: ...eet the requirements of the PACS Field Description Communication Sets the communication mode Wiegand Default Clock Data Data Output SIO and EPC Default SIO Only EPC Only Anti Passback Timer Set the An...

Страница 23: ...he UHF field can be enabled Autotune Now This option will immediately run the autotune function The diagnostic LED is blue while Reader is Autotunning and Red when Complete Note UHF Autotune Enable mu...

Страница 24: ...merica China China Croatia Europe Cyprus Europe Czech Republic Europe Denmark Europe Estonia Europe Finland Europe France Europe Germany Europe Greece Europe Hungary Europe India India Ireland Europe...

Страница 25: ...a No Hold Reader will continuously poll and report data per the Grant Access settings Parking Hold Default Reader will not poll and therefore not report tag data unless the hold line is high Released...

Страница 26: ...either trigger on an input on the GRN terminal pin Host Controlled or when the diagnostic LED is green Reader Controlled indicating an SIO has been read Red LED The relay will either trigger on an in...

Страница 27: ...ecked When enabled the SCBK Default option is available SCBK Default Secure Channel Base Key Default See SIA OSDP Specification Appendix D This field requires the Install Mode to be enabled The SCBK D...

Страница 28: ...rade Firmware Click Browse to locate the upgrade firmware file Click Upgrade Firmware to begin the upgrade process See Section 5 3 General Information for detailed update information Upload Config Cli...

Страница 29: ...set the Static IP IP Address IP address of the reader used if DHCP is not enabled TFTP Enabled Enables disables the TFTP server for firmware and configuration IP Address Displays the current IP addre...

Страница 30: ...oot System Log into the reader with the new password Note If the password has been lost see Section 6 Restore Default Settings for instructions to reset the password to the default setting Confirm Use...

Страница 31: ...and password for the U90 Reader Management GUI To restore the network setting to default 1 Remove power from the reader 2 Place the jumper between pins P1 5 OC TMPR and P1 2 GRN 3 Restore power to re...

Страница 32: ...allation 3 Press the suction cups firmly against the windshield so a vacuum seal is formed 4 Slide the card into the mount Special Note Tinted Windshields Some vehicles have a conductive tinted area a...

Страница 33: ...st 2A Reader is not properly tuned Refer to section Card has already been read and is in Anti Passback Remove card from RF field for the duration of the Anti Passback setting and re present A card tha...

Страница 34: ...ion make sure the IP address is 192 168 63 99 Computer network and reader are not in the same range Ensure computer network adapter IP settings are in the same range as reader i e 192 168 63 xx Change...

Страница 35: ...Page i PLT 01952 Version A 2 June 2014 This page intentionally left blank...

Страница 36: ...hidglobal com...

Отзывы: