background image

An ASSA ABLOY Group brand

INSTALLATION GUIDE

Page 12

EDGE EVO

  

  82000-921, Rev. D.3

HID Global

Americas & Corporate

611 Center Ridge Drive

Austin, TX 78753

USA

Support:  866-607-7339

Fax: 

 949-732-2120

Asia Pacific

19/F 625 King's Road

North Point, Island East

Hong Kong

Support:   852-3160-9833

Fax: 

  852-3160-4809

Europe, Middle East & Africa

Haverhill Business Park Phoenix Road

Haverhill, Suffolk CB9 7AE

England

Support:  44 (0) 1440 711 822

Fax: 

 44 (0) 1440 714 840

Patent Pending

Check reader label for current regulatory approvals.

For additional offices around the world, see www.hidglobal.com corporate offices.
HID Global Customer Support: support.hidglobal.com

Regulatory

UL

Connect only to a Listed Access Control / Burglary power-limited power supply, or Listed Access Control / Burglary PoE (Power-over-Ethernet) adapter. 
All National and local Electrical codes apply.  Install in accordance with NFPA70 (NEC), Local Codes, and authorities having jurisdiction. Host-based security, Ethernet / Host 
Communication, has not been evaluated by UL. Ethernet port has been evaluated for supplemental use only.
Indoor use only. 
The EDGE EVO family has been evaluated for standalone Access Control.
Mount onto UL Listed Single-Gang electrical box.
Hi-O Networked Controller and EDGE EVO Modules are UL Listed for installation within the protected area.
All panic and alarm hardware and equipment shall be UL Listed.
All cabling and wire shall be UL Listed or Recognized and suitable for the application.
All splices and connections shall be mechanically secure and bonded electrically.
EDGE EVO was evaluated for use with all Listed HID Global Wiegand models: iCLASS, Indala Prox, HID Prox, bioCLASS, SmartID, SmartTRANS, and Mag Stripe series (with 
and without keypad), up to 128-bit formats. EDGE EVO was evaluated for use with all HID Global Hi-O iCLASS readers.
Hi-O Networked Controller is UL Listed for installation in the unprotected area, as well as within the protected area.

CAUTION: Any changes or modifications to this devise not explicitly approved by the manufacturer could void your authority to operate this equipment.

FCC

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this 
device must accept any interference received, including interference that may cause undesired operation.

Canada Radio Certification

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference,  
and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: 
(1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en 
compromettre le fonctionnement.

CE MARKING

HID Global hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
Por el presente, HID Global declara que estos lectores de proximidad cumplen con los requisitos esenciales y otras disposiciones relevantes de la Directiva 1999/5/EC.
HID Global déclare par la présente que ces lecteurs à proximité sont conformes aux exigences essentielles et aux autres stipulations pertinentes de la Directive 
1999/5/CE.
A HID Global, por meio deste, declara que estes leitores de proximidade estão em conformidade com as exigências essenciais e outras condições da diretiva 1999/5/EC.
HID Global bestätigt hiermit, dass die Leser die wesentlichen Anforderungen und anderen relevanten Bestimmungen der Richtlinie 1999/5/EG erfüllen.
HID Global dichiara che i lettori di prossimità sono conformi ai requisiti essenziali e ad altre misure rilevanti come previsto dalla Direttiva europea 1999/5/EC.

Download copies of the R&TTE Declaration of Conformity (DoC) at 

http://www.hidglobal.com/certifications

.

JAPAN MIC

この装置は認証済みです。

TAIWAN NCC

經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。低功率射頻電機之使用
不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無線電
通信。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。

According to «Administrative Regulations on Low Power Radio Waves Radiated Devices» without permission granted by the NCC, any company, enterprise, or user is not 
allowed to change frequency, enhance transmitting power or alter original characteristic as well as performance to an approved low power radio-frequency devices. The 
low power radio-frequency devices shall not influence aircraft security and interfere legal communications; If found, the user shall cease operating immediately until no 
interference is achieved. The said legal communications means radio communications is operated in compliance with the Telecommunications Act.

The low power radio-frequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated devices.
This product includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (

http://www.openssl.org

). 

Содержание EDGE EVO EH400-K

Страница 1: ...ch Hi O device such as the push plate electric strike card reader and door operator is connected to the CANbus by a single four wire cable Two wires supply power and the other two are used for data communication Specifications CONDITIONS VOLTAGE DC CURRENT POWER OPERATING TEMPERATURE CABLE LENGTH REGULATORY REFNUMBER INPUT DC Input NSC 12 VDC 0 18 Amp 2 16 W 32 122 F 0 50 C Hi O CANbus Total Lengt...

Страница 2: ...ntroller EH400 K Provides access control and manages all peripherals around the door iCLASS Wiegand Reader Provides entry into the secured area Step 2 Create System Layout Using the components identified in Step 1 Identify System Componentscreate the system layout In this example the EH400 K is connected to the remote server through an Ethernet connection and manages door peripherals over the Hi O...

Страница 3: ...for all door peripherals all Hi O interface devices and all Hi O enabled readers with the following equation adding terms as required I total I dps I mag I rex I EDM M For this example the total current draw equals the following I total 12VDC 15mA 300mA 28mA 150mA 493mA I total 24VDC 15mA 150mA 38mA 150mA 353mA Compare the required current draw I total to the output current capacity of the EH400 K...

Страница 4: ...c Lock REX Switch Wiegand Reader EH400 K Unprotected Area Reader Power Ethernet Power Wiega Door Po Swi Magne ader cted Reade Physical Access Control Server real time functions not required Ethernet Switch UL 294 PoE Injector er Power Scheme 2 Standard Networked Controller power derived from an external 12VDC or 24VDC power supply Standard Networked Controller is connected directly to the Ethernet...

Страница 5: ...6 P4 P7 Ethernet PoE Auto Detected Activity LED Link LED Hi O CANbus Reader Tamper CAP Restore Network Defaults Jumper CAUTION Some magnetic locks exhibit both high inrush current when activated and a high instantaneous break voltage when de energized due to magnetic field collapse It is recommended you use of a snubber circuit across the controlling relay terminals to protect the controlling rela...

Страница 6: ...er with an Ethernet cable 2 Select Start Run and enter ipconfig renew 3 Open a web browser and enter 169 254 242 121 into the Address field Discovery GUI for DHCP Networks With a DHCP network use the HID Discovery GUI on the PC to locate and connect the Controller Note The Controller must be connected to the network before power is applied for DHCP to function Java is required for the Discovery GU...

Страница 7: ...te On subsequent sessions the password may be changed by the user The password must be between 6 to 10 characters long and can include all printable ASCII characters from 32 to 126 decimal Reference http www asciitable com For EDGE EVO Solo see the EDGE EVO Solo User Guide 83000 902 rev B x 7 Power Testing Test the system once per year using the web Graphical User Interface to ensure all wiring an...

Страница 8: ...onents around and behind doors and other access points For Hi O interface module wiring see their respective Installation Guides go to www hidglobal com Support Document Library and search the document type Installation Guide Model Description Part Number EDM M EDGE EVO Door Module 82342 EIM M EDGE EVO Input Module 82340 EWM M EDGE EVO Reader Module 82360 EDWM M EDGE EVO Door Reader Module 82363AM...

Страница 9: ...g network defaults 1 Remove the back plate on the EDGE EVO 2 Loosen the Mylar cover Note For the jumper location see the diagram in Section 3 Wiring 3 Reboot the controller and place the supplied jumper over pins 3 and 5 of the Debug port after the beep The Debug port is an eight pin header located above and to the right of the Ethernet connector underneath the Mylar Note The network reset opportu...

Страница 10: ...re is completed and the unit will fail to boot correctly 4 Provided the jumper is correctly fitted within the specified time the unit will beep with 2 short beeps then a pause This beep pause cycle will continue indefinitely until the jumper is removed 5 Remove the jumper The beeps will cease 6 Wait a minimum of 1 second then reapply the jumper The jumper must be reapplied within 15 seconds of rem...

Страница 11: ...rvised Normally Closed contact replacing one of the pre installed jumpers B 3 Relay Jumpers AUX Wet CAN V AUX Wet 12VDC AUX Dry DS Wet CAN V DS Wet 12VDC DS Dry 3 1 P9 P5 P8 3 1 3 1 3 1 P6 P4 P7 3 1 3 1 JUMPER B 4Tamper Reader Interface Board The Reader Tamper and are implemented allowing a connection for an open collector external tamper from a reader such as iCLASS Note Connect P2 Pin 2 GND from...

Страница 12: ...evice may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appare...