Hush & Breeze Wall Mounted Fans

Thank you for purchasing this HiB product. 

Please read through these instructions carefully and refer back to them during 
installation to ensure that your product is fitted safely and that it retains its high 
quality finish.

Please retain this leaflet for future reference.

Before drilling, ensure there are no hidden cables or pipes in the wall

Please see Fig. 1 on the back page for details 

Suitable for installation in zones: 2 & Outside Zones

Beeze Chrome

 

Timer

 

Art no.

32800

Timer & Humidity Sensor

 

Art no.

32900

Breeze Matt Silver

Timer

 

Art no.

31300

Timer & Humidity Sensor

 

Art no.

31400

Breeze White

Timer

 

Art no.

31100

Timer & Humidity Sensor

 

Art no.

31200

Hush Chrome

 

Timer

 

Art no.

33100 

Timer & Humidity Sensor 

Art no.

33200

Hush Matt Silver

Timer

 

Art no.

31700

Timer & Humidity Sensor

 

Art no.

31800

Hush White

Timer

 

Art no.

31500

Timer & Humidity Sensor

 

Art no.

31600

Содержание Hush 33100

Страница 1: ...sure there are no hidden cables or pipes in the wall Please see Fig 1 on the back page for details Suitable for installation in zones 2 Outside Zones Beeze Chrome Timer Art no 32800 Timer Humidity Sensor Art no 32900 Breeze Matt Silver Timer Art no 31300 Timer Humidity Sensor Art no 31400 Breeze White Timer Art no 31100 Timer Humidity Sensor Art no 31200 Hush Chrome Timer Art no 33100 Timer Humidi...

Страница 2: ...ste 4 If necessary use a chisel and hammer to cut grooves in your internal plasterwork to take the cable and conduit 5 Fit flexible ducting into the hole flush with both sides of the wall Ensure the duct slopes slightly downwards towards the outside Make good any plasterwork around the duct 6 Position the fan back into place and mark the four fixing points Drill the required holes in the marked po...

Страница 3: ...For Art Nos 33200 31800 31600 3290 0 31400 31200 Fan with timer and humidity sensor switches on as control voltage is supplied to LT terminal or when humidity level adjustable between 60 and 90 is exceeded After voltage is off or humidity level H decreases the fan continues operating within the set time period adjustable between 2 and 30 min Time T and humidity H values are regulated by turning th...

Страница 4: ...try and make sure they are as accurate as possible In the interest of continuous product development HiB reserves the right to alter specifications as necessary E OE T 44 0 20 8441 0352 F 44 0 20 8441 0219 E sales hib co uk hib co uk Building 3 North London Business Park Oakleigh Road South New Southgate London N11 1GN Fig 1 Electrical Safety Information Ensure mains power supply is switched off b...

Отзывы: