6.3. OLP - indications on the controller
XSDrive
OLP boom system: The cylinder LEDs indicate a
percentage of maximum pressure:
• 70% of maximum pressure reached - lower LED on each
cylinder light green
• 90% of maximum pressure reached - lower LED on each
cylinder flash red
• 100% of maximum pressure reached - both LEDs on
each cylinder light red
OLP stabiliser system [option]: No indication on the
controller. See indications on the user panel.
VSL-OLP [option]: The LED for VSL light red.
CombiDrive
OLP boom system shown on the left and right displays:
• A percentage of maximum permitted pressure in the
cylinders is shown on the displays. When 50% or more of
maximum pressure is reached, the percentage alternates
with the function symbol once a second in the display
corresponding to each lever. The display shows 50%,
70%, 90% and 100% as the pressure increase.
• When pressure reaches 100 %, all functions that would
increase pressure are blocked. If the operator attempts
to operate a blocked function, the function symbol is
replaced by a cross while the lever is engaged. When the
lever is returned to neutral position, the cross disappears
and the function symbol returns. Operate permitted
(pressure reducing) functions only. In an OLP situation,
symbol "x" is shown in every menu in the centre display.
50%
70%
90%
100%
During operation
HIAB K-HiPro 285-425 X4
77