Hi-Force AHP1120б Series Скачать руководство пользователя страница 7

 

INSTRUCTION MANUAL – AIR DRIVEN HYDRAULIC PUMPS:  

Model Series: AHP1120, AHP1120R, AHP1121, AHP1121R, AHP1122, AHP1122R, AHP1141, AHP1142,  

HAP21011, HAP21012, HAP21014, HAP21016, HAP21021, HAP21022, HAP21024, HAP21026, HAP21031, 

HAP21032, HAP21034, HAP21036, HAP21041, HAP21042, HAP21044, HAP21046,   

Hi

Force

 

Limited

 

 

Prospect

 

Way

 

 

Daventry

 

 

Northants

 

NN11

 

8PL

 

 

United

 

Kingdom

 

Tel:

 

+44(0)

 

1327

 

301000:

  

Fax:

 

+44(0)

 

1327

 

706555:

 

Website:

 

www.hi

force.com

  

 

under the skin see a doctor 
immediately. 

 

Never pressurise uncoupled couplers. 

 

Always use eye, ear and hand 
protective equipment when using this 
pump and associated equipment 

 
10.0 Identification of Components. 
Refer to diagrams on following pages. 

1.

 

Oil reservoir 

2.

 

Hydraulic Oil level gauge 

3.

 

Oil filler breather cap 

4.

 

Motor 

5.

 

Silencer 

6.

 

Adjustable pressure relief valve 

7.

 

Hydraulic directional control valve – if 
fitted (type will vary) 

8.

 

Hydraulic service connections 

9.

 

Hydraulic oil drain plug 

10.

 

Roll frame (optional) 

11.

 

Motor air inlet. 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

 

 

 

 

 

11.0 Preparing the Pump for first use: 

1.

 

Immediately after unpacking, examine 
the pump for signs of transit damage 
and if found contact the shipping 
company. 

2.

 

Establish the oil level in the oil reservoir 
using the level gauge on the end of 
the tank. Depending on the shipping 
method used, the reservoir may either 
be supplied full or empty. If the 
reservoir is empty it must be correctly 

filled before use. Remove the 
temporary transit plate which is fitted in 
the position of the filler breather cap 
(3) by undoing the 3 screws. Fit the filler 
breather cap (packed separately) 
using the 3 screws which held the 
transit plate. 

3.

 

To fill the reservoir: Remove the filler 
cap (3) and fill the tank with clean 
HFO46 oil to the upper level indicator 
(2). 

4.

 

Connect the air supply to the Motor air 
inlet (11). Max inlet pressure 7 bar. It is 
recommended that a filter and 
lubricator are incorporated in the air 
supply. 

5.

 

Ensure your air supply circuit includes a 
ball or sliding valve close at hand, 
which can be used to control the air 
supply. 

6.

 

Remove hexagon headed plugs and 
make hydraulic connections to service 
ports (8).These ports have a 3/8” NPT 

female thread and the corresponding 
male connections should be wrapped 
with PTFE tape or other suitable 
sealant. 

 

7.

 

Ensure the lever of the hydraulic 
directional control valve (7) is in the 
neutral position. This is fully 
anticlockwise for models with 2 way 
valve (HAP21021, HAP21022, HAP21024, 

Содержание AHP1120б Series

Страница 1: ...nt as specified by their employer is worn when operating any hydraulic equipment Safety shoes safety glasses visor and protective gloves should be worn at all times All relevant risk assessments shoul...

Страница 2: ...ximum importance for your own safety and the safety of others In addition to the safety warnings in this section please also take note of all safety related issues in other sections of this manual DO...

Страница 3: ...essed air line Select a quick coupler that is compatible with the air line supply and connect it to the air inlet connection Fig 1 6 Operation 6 1 AHP1120 AHP1121 AHP1122 To start the pump press down...

Страница 4: ...n is released the pump stops but the pressure is maintained on the oil side so that the connected cylinder holds the load in the position it has reached To return the pressure to zero and hence retrac...

Страница 5: ...ing the recommended types of oil 7 3 2 Checking the hydraulic oil on the 5 10 Litre pump AHP1121 R 1122 R 1141 1142 Periodically check the oil level which must be between the two notches on the oil ca...

Страница 6: ...t hoses regularly for damage and wear Do not use hoses that are frayed abraded or leaking Never move the pump by pulling the hoses Do not work with hoses sharply bent or kinked Do not handle hoses tha...

Страница 7: ...the shipping company 2 Establish the oil level in the oil reservoir using the level gauge on the end of the tank Depending on the shipping method used the reservoir may either be supplied full or empt...

Страница 8: ...t anti clockwise will supply oil to the port and advance the cylinder Moving the lever away from the service port will connect the service port to tank and retract the cylinder 4 For pumps with 4 way...